QUENCHING DILATOMETER RITA L78
Open the catalog to page 1This practice is based upon the principle that, during heating and cooling of steels, dimensional changes occur as a result of both thermal expansions associated with temperature change and phase transformation. In this practice, sensitive high-speed quenching dilatometer equipment is used to detect and measure the changes in dimension that occur as functions of both time and temperature during dened thermal cycles. The resulting data are converted to discrete values of strain for specic values of time and temperature during the thermal cycle. Strain as a function of time or temperature, or both,...
Open the catalog to page 2Operation Method Operation Method of Quenching Dilatometer A solid or hollow sample is continuously heated to a certain temperature plateau. At this plateau a continuous cooling is started. The cooling is repeated at different (linear or exponential) cooling rates. The phase transformations occurring in the different cooling cycles are indicated by the measured change of length. An array of cooling curves with different cool down cycles represents a continuous or isothermal TTT diagram (Time Temperature Transformation diagram). Start and stop of the transformation dene the elds of e.g. ferrite,...
Open the catalog to page 3Technical Specifications Features -Software • Program capable of text editing All LINSEIS thermo analytical instruments are PC controlled. The indi- • Data security in case of power failure vidual software modules exclusively run under Microsoft® Windows® • Thermocouple break protection operating systems. The complete software consists of 3 modules: tem- • Repetition measurements with minimum parameter input perature control, data acquisition and data evaluation. The 32 bit soft- • Evaluation of current measurement ware incorporates all essential features for measurement preparation, • Curve...
Open the catalog to page 4LINSEIS GmbH Vielitzerstr. 43 95100 Selb Germany Tel.: (+49) 9287–880 - 0 Fax: (+49) 9287–70488 E-mail: [email protected] LINSEIS Inc. 109 North Gold Drive Robbinsville, NJ 08691 USA Tel.: (+1) 609 223 2070 Fax: (+1) 609 223 2074 E-mail: [email protected] Products: DIL, TG, STA, DSC, HDSC, DTA, TMA, MS/FTIR, In-Situ EGA, Laser Flash, Seebeck Effect Services: Service Lab, Calibration Service
Open the catalog to page 812 Pages
24 Pages
20 Pages
5 Pages
7 Pages
4 Pages
9 Pages
15 Pages
5 Pages
2 Pages
12 Pages
6 Pages
8 Pages
8 Pages
2 Pages
6 Pages
8 Pages
2 Pages
3 Pages
3 Pages
3 Pages