DL8829, Digital Temperature & Humidity data logger
1Pages

{{requestButtons}}

Catalog excerpts

DL8829, Digital Temperature & Humidity data logger - 1

DATA LOGGERS & ACCESSORIES Model DL8829 DIGITAL TEMPERATURE & HUMIDITY DATA LOGGER DIGITAL TEMPERATURE DATA LOGGER TEMPERATURE DATA LOGGER • Records relative humidity and temperature • Logs data for days, weeks or months • Multiple data loggers can be programmed and data downloaded from a single docking station • Programmable sampling rate from 1 sec. to 2 hrs. • View either temperature or humidity on LCD • Program the data logger, analyze and store data using Windows® 95/98/2000/NT/XP compatible software • Yellow record LED flashes when unit is sampling • Scheduled, magnetic or immediate start capability • Real time clock stores date and time with data • Programmable high and low limits with alarm • Docking station, RS-232 cable, Windows® 95/98/2000/NT/XP compatible software and 3.6V lithium battery sold separately (Model INT8818) • NOTE: The data logger by itself cannot function without the software and docking station • Records temperature only • Logs data for days, weeks or months • Multiple data loggers can be programmed and data downloaded from a single docking station • Programmable sampling rate from 1 sec. to 2 hrs.. • View temperature on LCD • Program the data logger, analyze and store data using Windows® 95/98/2000/NT/XP compatible software • Yellow record LED flashes when unit is sampling • Scheduled, magnetic or immediate start capability • Real time clock stores date and time with data • Programmable high and low limits with alarm • Docking station, RS-232 cable, Windows® 95/98/2000/NT/XP compatible software and 3.6V lithium battery sold separately (Model INT8818) • NOTE: The data logger by itself cannot function without the software and docking station • Collect temperature data for QC • Rugged, waterproof housing • Start and stop logging by programmed schedule or internal magnetic switch • Sampling interval from 1 sec. to 2 hrs.. • User-defined min/max alarm setting • Data is retained in non-volatile memory, no loss when battery is low or has been removed • Collect up to 8000 temperature samples • Real-time clock memory • Ideal for monitoring ambient conditions in greenhouses, warehouses, food transport, aircraft cabins, art galleries, museums and much more • Docking station, RS-232 cable, Windows® 95/98/2000/NT/XP compatible software and 3.6V lithium battery sold separately (Model INT8818) • NOTE: The data logger by itself cannot function without the software and docking station • Temp. Range: -40˚F to 185˚F (-40°C to 85°C) • Humidity Range: 0 to 100%RH • Accuracy: ± 1°F from -4 to 122°F, ± 2°F at all other ranges; ±5% RH • Resolution: 0.1˚, 0.1% RH • Memory: Temp: up to 8,000; RH: 8,000 points • Dimensions: 3.14" x 2.16" x 0.86" • Weight: 2.6 oz. (76g) • Temp. Range: -40˚F to 185˚F (-40°C to 85°C) • Accuracy: ± 1°F from -4 to 122°F, ± 2°F otherwise (±0.6°C from -20 to 50°C, ±1.2°C otherwise) • Resolution: 0.1˚ • Memory: up to 16,000 points • Dimensions: 3.14" x 2.16" x 0.86" • Weight: 2.6 oz. (76g) • Temperature range: -40˚ to 185˚F (-40 to 85˚C) • Accuracy: ± 1°F from -4 to 122°F, ± 2°F otherwise (±0.6°C from -20 to 50°C, ±1.2°C otherwise) • Resolution: 0.1˚ • Temperature sensor: Thermistor • Memory: up to 8,000 points • Dimension: 4.25” x 2.5” x 0.86” • Weight: 0.9 oz (26g) DATA LOGGER INTERFACE KIT DESKTOP PRINTER DATA LOGGERS • For use with the above listed data loggers • For use with the above listed data loggers (Models DL8829, DL8828, DL8808) • Prints collected data in text or graph format • Small size fits in the palm of your hand • LCD display with Matrix LCD • Input: RS-232C Data: 8 bits; Stop: 1 bit • Baud rate selectable at 4800 bps or 9600 bps • Dimension: 4.72” x 5.9” x 1.88” • Includes printer, thermo-paper and batteries • Set up data loggers without a personal computer for start recording, sampling interval, recording points, hi/low temperature or humidity alarm setting,˚C or ˚F • Printing characteristics: a) Voltage compensating to stabilize the contrast of printing, b) Paper jam protection, c) Paper feed, d) Printing contrast: 1 to 9, e) Print type by report or graphic (Font: Roman 8) • Downloads collected data to your PC via the docking station and RS-232 cable for • Using the INT8818 will enable you to display all collected information on your PC or laptop • Software compatible with Windows® 95/98/2000/NT/XP • Includes data logger base, RS-232 cable and Windows® software • NOTE: This kit is necessary in order to correctly use all data loggers Linseis Inc. • P.O. BOX 6866 • Princeton Jct., NJ 08850 • (609) 799-6282 • FAX (609) 799-7739 • WWW.Linseis.COM DL 11/02

Open the catalog to page 1

All Linseis Thermal Analysis catalogs and technical brochures

  1. LZT

    9 Pages

  2. L81_500LT

    3 Pages

Archived catalogs