DATA LOGGERS & ACCESSORIES Model DL8829 DIGITAL TEMPERATURE & HUMIDITY DATA LOGGER DIGITAL TEMPERATURE DATA LOGGER TEMPERATURE DATA LOGGER • Records relative humidity and temperature • Logs data for days, weeks or months • Multiple data loggers can be programmed and data downloaded from a single docking station • Programmable sampling rate from 1 sec. to 2 hrs. • View either temperature or humidity on LCD • Program the data logger, analyze and store data using Windows® 95/98/2000/NT/XP compatible software • Yellow record LED flashes when unit is sampling • Scheduled, magnetic or immediate start capability • Real time clock stores date and time with data • Programmable high and low limits with alarm • Docking station, RS-232 cable, Windows® 95/98/2000/NT/XP compatible software and 3.6V lithium battery sold separately (Model INT8818) • NOTE: The data logger by itself cannot function without the software and docking station • Records temperature only • Logs data for days, weeks or months • Multiple data loggers can be programmed and data downloaded from a single docking station • Programmable sampling rate from 1 sec. to 2 hrs.. • View temperature on LCD • Program the data logger, analyze and store data using Windows® 95/98/2000/NT/XP compatible software • Yellow record LED flashes when unit is sampling • Scheduled, magnetic or immediate start capability • Real time clock stores date and time with data • Programmable high and low limits with alarm • Docking station, RS-232 cable, Windows® 95/98/2000/NT/XP compatible software and 3.6V lithium battery sold separately (Model INT8818) • NOTE: The data logger by itself cannot function without the software and docking station • Collect temperature data for QC • Rugged, waterproof housing • Start and stop logging by programmed schedule or internal magnetic switch • Sampling interval from 1 sec. to 2 hrs.. • User-defined min/max alarm setting • Data is retained in non-volatile memory, no loss when battery is low or has been removed • Collect up to 8000 temperature samples • Real-time clock memory • Ideal for monitoring ambient conditions in greenhouses, warehouses, food transport, aircraft cabins, art galleries, museums and much more • Docking station, RS-232 cable, Windows® 95/98/2000/NT/XP compatible software and 3.6V lithium battery sold separately (Model INT8818) • NOTE: The data logger by itself cannot function without the software and docking station • Temp. Range: -40˚F to 185˚F (-40°C to 85°C) • Humidity Range: 0 to 100%RH • Accuracy: ± 1°F from -4 to 122°F, ± 2°F at all other ranges; ±5% RH • Resolution: 0.1˚, 0.1% RH • Memory: Temp: up to 8,000; RH: 8,000 points • Dimensions: 3.14" x 2.16" x 0.86" • Weight: 2.6 oz. (76g) • Temp. Range: -40˚F to 185˚F (-40°C to 85°C) • Accuracy: ± 1°F from -4 to 122°F, ± 2°F otherwise (±0.6°C from -20 to 50°C, ±1.2°C otherwise) • Resolution: 0.1˚ • Memory: up to 16,000 points • Dimensions: 3.14" x 2.16" x 0.86" • Weight: 2.6 oz. (76g) • Temperature range: -40˚ to 185˚F (-40 to 85˚C) • Accuracy: ± 1°F from -4 to 122°F, ± 2°F otherwise (±0.6°C from -20 to 50°C, ±1.2°C otherwise) • Resolution: 0.1˚ • Temperature sensor: Thermistor • Memory: up to 8,000 points • Dimension: 4.25” x 2.5” x 0.86” • Weight: 0.9 oz (26g) DATA LOGGER INTERFACE KIT DESKTOP PRINTER DATA LOGGERS • For use with the above listed data loggers • For use with the above listed data loggers (Models DL8829, DL8828, DL8808) • Prints collected data in text or graph format • Small size fits in the palm of your hand • LCD display with Matrix LCD • Input: RS-232C Data: 8 bits; Stop: 1 bit • Baud rate selectable at 4800 bps or 9600 bps • Dimension: 4.72” x 5.9” x 1.88” • Includes printer, thermo-paper and batteries • Set up data loggers without a personal computer for start recording, sampling interval, recording points, hi/low temperature or humidity alarm setting,˚C or ˚F • Printing characteristics: a) Voltage compensating to stabilize the contrast of printing, b) Paper jam protection, c) Paper feed, d) Printing contrast: 1 to 9, e) Print type by report or graphic (Font: Roman 8) • Downloads collected data to your PC via the docking station and RS-232 cable for • Using the INT8818 will enable you to display all collected information on your PC or laptop • Software compatible with Windows® 95/98/2000/NT/XP • Includes data logger base, RS-232 cable and Windows® software • NOTE: This kit is necessary in order to correctly use all data loggers Linseis Inc. • P.O. BOX 6866 • Princeton Jct., NJ 08850 • (609) 799-6282 • FAX (609) 799-7739 • WWW.Linseis.COM DL 11/02

 Open the catalog to page 1

All Linseis Thermal Analysis catalogs and technical brochures

  1. LZT

    9  Pages

  2. L81_500LT

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.