video corpo

Centralized Power and Control Systems
84Pages

{{requestButtons}}

Catalog excerpts

Centralized Power and Control Systems - 1

EMERGENCY LIGHTING CENTRALIZED POWER AND CONTROL SYSTEMS

Open the catalog to page 1
Centralized Power and Control Systems - 3

GUIDE TO THE EMERGENCY LUMINAIRES

Open the catalog to page 3
Centralized Power and Control Systems - 4

SUPPORT AND SERVICES Shipping by express courier Telephone technical support The dispatch of standard equipment orders is executed within 5 working days and is entrusted to express couriers, guaranteeing nationwide delivery within 24 hours. Linergy provides the customer a telephone technical support service managed in-house by the company. Sales network NUMERI TELEFONICI: Switchboard 0735 5974 Technical telephone support 0735 597424 Technical support for Spy Center 0735 597454 Technical support for Spy System 0735 597425 Lighting technical design 0735 597427 0735 597428 0735 597429 Linergy...

Open the catalog to page 4
Centralized Power and Control Systems - 5

Online website with constantly updated information on the Linergy world. On www.linergy.it you’ll find all the latest news on products and on sales network and you can also download instructions manuals, certificates, price lists and data sheets.

Open the catalog to page 5
Centralized Power and Control Systems - 6

What are these? Emergency luminaires are used to obtain safety lighting when electricity and ordinary lights fail. Why use them? The law and various technical regulations require the presence of safety lighting in all workplaces, in order to avoid any discomfort and, specifically, to ensure people's safety in the event of a power cut, the presence of a fire or any other incident. How should you choose them? The correct choice of emergency lighting requires knowledge of the various types of luminaires and their main features. TYPE OF OPERATION Non-maintained models or N/M type The luminaire...

Open the catalog to page 6
Centralized Power and Control Systems - 7

AL Atex Led AS Astra BG Big One CE Cristal Evo CM Cometa CR/CS Cristal CW Cristal Wall DL Dual DU Dual Led EF/EU Evolution Flu EI Euroinverter EL/ES Evolution Led FT Fastinverter L / Alta Resa T8 FX Fox IC Ice IT Icetek KL K-Led LD/LS Ledy LI/LH Led Inverter LV Lyra Evo LX Lexit MB/ML MoonLed NL Nanoled OR Orion PR/PS Prodigy QU Qube SB Seven Glass SC Spy Center SC24 Spy Center24 SCB Spy Center Basic SCL Spy Center LPS SF Seven Plus SG Seven Plus Led SS Spy System ST Step SW Swing VD Vip Led VE Vialed Evo VH Vialed High VN Vialed Net VT/VU Vialed Tube VW VialedWall L Litio N Nickel Cadmium...

Open the catalog to page 7
Centralized Power and Control Systems - 9

EMERGENCY LUMINAIRE Fig. 1 INHIBIT chart Connection with inhibition; For correct installation, the switch must be positioned in a place accessible only to personnel authorised to carry out maintenance. Fig. 2 REST MODE chart Connection with Rest Mode (standard connection) EXTRA MOVIE "Movie" series luminaires are suitable for cinemas and theatres, Under normal Movie version for public enterta|nment conditions, lighting is installed so as not to detract from the show, but to ensure venues that emergency exits routes are clearly visible, In the event of an emergency, the luminaires provide...

Open the catalog to page 9
Centralized Power and Control Systems - 10

SAFETY LIGHTING Lighting High-risk activity RESERVE LIGHTING In the absence of ordinary lighting, allows activities to continue. SAFETY LIGHTING Emergency exit route Illuminates and indicates the emergency exit route from rooms to the safe place. Features: ■ pictogram on a green background that must cover at least 50% of the surface ■ rectangular or square shape ■ the correct dimensions must be ensured for clear visibility ■ the message must be clear and immediate and must comply with UNI EN 1838 and UNI EN ISO 7010 standards. Back lighting (unlike the external lighting) ensures increased...

Open the catalog to page 10
Centralized Power and Control Systems - 11

■ Close to every emergency door ■ Close to stairs, so the ramp receives direct light ■ Close to each level variation ■ On the safety signs for externally illuminated emergency exit routes ■ For each change in direction ■ At every corridor intersection ■ Close to each exit and outside the building to the safe location ■ Close to each emergency point, 5 lux ■ Close to every fire protection device and call point, 5 lux ■ Close to all evacuation equipment for the disabled ■ Close to shelters and gathering points for the disabled ■ In toilet facilities for the disabled (close is understood as...

Open the catalog to page 11
Centralized Power and Control Systems - 13

What are they? These are systems that use a computerised control unit to control all the luminaires in an emergency system. The control unit has the ability to manage and store information from the luminaires and ensures perfect and timely maintenance of the system. The latest generation of systems, such as those made by LINERGY, along with complete programmability of all system variables, allows advanced information management and communication with other intelligent management systems with which they integrate perfectly. Why use them? The regulations prescribe that emergency equipment...

Open the catalog to page 13
Centralized Power and Control Systems - 15

CENTRALIZED CONTROL SYSTEMS For the management and maintenance of emergency installations with self-contained luminaires

Open the catalog to page 15
Centralized Power and Control Systems - 16

I 1.0 SPY SYSTEM SPY SYSTEM is the most advanced system for the complete management, supervision and maintenance of an emergency system with self-contained luminaires. ■ NEW AND MORE INTUITIVE GRAPHICS ■ VIRTUAL KEYPAD ON TOUCH SCREEN LCD ■ POSSIBILITY TO UPDATE STATION SOFTWARE ■ POSSIBILITY TO MODIFY THE APPLIANCE'S SERIAL NUMBERS ■ POSSIBILITY TO SWITCH ON/OFF MAINTAINED APPLIANCES* ■ POSSIBILITY TO CHANGE THE LIGHT INTENSITY* *Only on appliances set-up The management of tests allows you to choose the date and time of execution for each of the 32 groups into which the system can be...

Open the catalog to page 16
Centralized Power and Control Systems - 17

Version Order code Short code Display Printer Max Luminaires Installation Protection rating Wall Wall Rack 19' (4 Units) Rack 19' (4 Units) DIN rail DIN rail IP20 DIN rail DIN rail DIN rail IP20 DIN rail Can be managed with Android and iOS devices via an app that can be downloaded from Wireless bridge for Spy System units Order Code Short Description Code SS-KNX-CENT A116 HW and sw interface konnex sscent SS-KNX-MINIA117 HW and sw interface konnex ssmini SS-MODBUS A118 SW interface for tcp/modbus SSPRINTER A121 Printer module for Spy Mini SSW-EXTENDER A270 Spy System wireless range extender...

Open the catalog to page 17
Centralized Power and Control Systems - 18

|_5.0 TECHNICAL DATA Power supply User Interface 7" colour touch-screen graphic display Thermal with 16 columns Autonomy in the absence of a network 4 hours (with saving of all data) Maximum number of managed luminaires 1280 with one control unit Connectable luminaires 256 on the control unit + 128 luminaires per repeater module Connectable repeaters 2 polarised cables (twisted and shielded cable) External Interfaces Ethernet protocol TCP/IP with web server | 6.0 MAIN FEATURES ■ Centralized control system for emergency installation with self-contained luminaires ■ Wireless option ■ 7"...

Open the catalog to page 18