Specifications:
MicroAir offers various pressure ranges in inches of water (0-3 to 0-100), PSI (0-3 and 0-5), and other units like mbar and kPa. The air connection requires 45 psi for single units and 55 psi for dual or multi-units, with 1/4 NPT fittings. Power supply options include 110/220 VAC, 50/60 Hz, with all units operating below 50 volts and protected by a 1/2 amp 250-volt fuse. All models are CE certified.

Performance:
Precision, repeatability, and stability are optimal for units with full scale less than 1 psi. Stability is < +/- 0.2% for 30 inches of water and < +/- 0.3% for psi. Accuracy is maintained with flow changes affecting pressure by less than +/- 0.2% for low ranges and +/- 0.5% for higher psi units. Repeatability is +/- 0.2% for low ranges and +/- 0.3% for 3 and 5 psi. Display resolution varies with Magnehelic meters at +/-2% and digital displays at +/-0.1% below 60” of water.

Control Features:
MicroAir I offers manual control with a 10-turn knob. MicroAir II includes manual control with dual-speed push buttons and optional remote control. MicroAir IV features a 10-turn manual potentiometer and linear or dual-state control options.

Output Options:
MicroAir II and IV provide voltage outputs (0-5, 1-6, or 0-10 volts) and current output (4-20 mA).

Mounting and Enclosure:
Vertical mounting is required with specific hole patterns. Enclosures are made of stainless steel with various sizes for different models.

Air Flow:
Input is < 2.5 SCFM per channel, with output varying by range. Maximum output flow rates range from 5 SCFH for 2-inch wc to 90 SCFH for 5 psi.

Pressure Graphs:
Supply pressure changes from 45 to 80 psi result in less than 0.3% variance for 3 and 5 psi units and less than 0.2% for units below 30” of water.
See more

Catalog excerpts

MicroAir Statistics-1

MicroAir Specifications Available Pressure Ranges:

 Open the catalog to page 1
MicroAir Statistics-2

PRESSURE GRAPHS: Changes in supply pressure from 45 to 80 psi will result in a variance of less than .3% of full scale on 3 and 5 psi units and less than .2% of full scale on units below 30” of water. On Line Controls, Inc, 9A Kane Industrial Dr., Hudson, MA 01749-2905 USA www.onlinecontrols.com Phone: 978-562-5353 * Fax: 978-562-8986 * Email:

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.