Measuring equipment for indoor air and quality assurance - 2

Measuring and test equipment for ventilation systems Take professional HVAC systems in operation, balance and check It is of very high importance that the ventilation system is In the light of the increasing demand of energy efficient working correctly. Not only to make the people perform buildings and interested building owners it is of outmost their best and enjoy a superior indoor climate but also to importance that there is proper balancing and that the achieve a climate that makes the building stay healthy flow rates complies with current standards and guide- and energy efficient. To...

Open the catalog to page 2
Measuring equipment for indoor air and quality assurance - 3

Leakage Tester Lindab Leakage Tester LT 600 is the improved version of the old, proven LT 510, that simply and correctly determines the normalized tightness classes. The LT 600 give you an opportunity to make a quick and convenient leakage test directly on site! A complete equipment for field measuring of leakage of • The unit automatically calculates leakage, leak- duct systems. All is contained in two trunks equipped age factor and whether the chosen leakage class is with code locks and shock-absorbing cladding. achieved. • The unit automatically runs the measurement cycle It consists of...

Open the catalog to page 3
Measuring equipment for indoor air and quality assurance - 4

Precision is no accident: the manometer PC 410 helps you to find the right features and settings for all products with variable k-factors such as plenum boxes and iris dampers. The pressure meter, PC 410 simplifies balancing of valves • Possibility to measure variable k-factors. and diffusers. The PC 410 can measure variable k-fac- • Logs data over time. tors. A fact that makes it perfect for use in combination • Magnet which attaches it to ducts. with the MBB-box from Lindab. • Transfers data via USB. • Can be operated with one hand. It also has a powerful magnet so that you can attach it...

Open the catalog to page 4
Measuring equipment for indoor air and quality assurance - 5

Which way does the supply air or exhaust air go? The smoke gun shows you immediatly and accurate. It is easy to handle and there is no doubt about the patterns of the airflow. The smoke gun SP makes it easy to find leaks in your • Makes it easy to find leaks. ventilation system. It is also very good for demonstrating • Makes it easy to demonstrate air flows. air flows, for example when controlling that your kitchen fan works as it should. The smoke from the smoke gun is • No need for an open flame to generate smoke. not hazardous and the smoke gun only dispenses smoke when the trigger is...

Open the catalog to page 5
Measuring equipment for indoor air and quality assurance - 6

Indoor Air Quality Meter CDL 210 The observations from CDL 210, Lindab indoor air quality meter, is a very good basis for everyone involved in the indoor environment and the management of the building, tenants, house owners, consultants and investors to decide how to proceed with the improvements of the indoor air quality The CDL 210 indoor air quality meter measures the CO2 level, the air temperature and the humidity and logs the measured data. It is therefore ideal for the monitoring and the evaluation of the interior climate in living spaces and • Logs data over time. • Transfers data...

Open the catalog to page 6
Measuring equipment for indoor air and quality assurance - 7

What is good indoor air quality? Present situation Guidelines for indoor CO2 concentration: In light of the recent discussion concerning the indoor air quality in schools, apartments, offices etc and its effects on people, the following questions should be asked: Temperature Is the present indoor air quality healthy for the Most people are satisfied with an indoor temperature people spending time there? between 18 and 21 C° but this varies with each indi- Is the present ventilation adequate and can you vidual person and situation. determine when to ventilate? Is opening a window sufficient...

Open the catalog to page 7
Measuring equipment for indoor air and quality assurance - 8

We are commited to making your life easier and our environment better. At Lindab our ambition is to simplify construc- We have set three long term goals aimed at tion for our customers. We do that by design- reducing our impact on the environment and ing our products with smart features that the climate. These goals are based on EU’s makes them easy to use. We are also working objectives for 2020 and mean that, taking on ways to reduce our impact on our environ- 2008 as our starting point, we will: ment and climate. We do that by developing methods to produce our solutions using a minimum...

Open the catalog to page 8

All LINDAB catalogs and technical brochures

  1. Professor XP

    7 Pages

  2. DCV ONE

    4 Pages

  3. LindabSRP25

    8 Pages

  4. LindabRubigo

    4 Pages

  5. KIR

    3 Pages

  6. KI

    3 Pages

  7. KDPF

    2 Pages

  8. FDV

    2 Pages

  9. AIRY

    6 Pages

  10. Plenum boxes

    8 Pages

  11. Battens

    8 Pages

  12. Purlins

    8 Pages

  13. Garage doors

    12 Pages

  14. Flashings

    8 Pages

  15. ROCA

    12 Pages

  16. SRP 25

    8 Pages

  17. Grilles

    46 Pages

  18. Wall diffusers

    44 Pages

  19. VAV

    65 Pages

Archived catalogs