TILTCOD IXA1R,IXA2R

TILTCOD IXA1R,IXA2R

TILTCOD IXA1R,IXA2R

Product catalog summary
Overview: The IXA1R and IXA2R are magnetic sensors with integrated converters, designed for precise inclination measurement. They feature redundant inclinometers with double sensor and output circuits, offering both analogue voltage and current outputs.
Key Features:
  • Redundant inclinometer with double sensor and output circuit.
  • Analogue voltage (0.5-4.5V) or current (4-20mA) output.
  • 1-axis operation (0-360 degrees) and 2-axes operation (±10, ±30, ±60 degrees).
  • Measurement accuracy of ±0.2 degrees.
  • Robust metal housing with IP67 protection.
Electrical Specifications:
  • Resolution: 0.05% of measurement range.
  • Accuracy: Typically ±0.2 degrees, maximum ±0.5 degrees for 2 axes up to ±30°.
  • MTTF: IXA1R = 258 years, IXA2R = 184 years.
  • Temperature drift: ±0.008 degrees/°C.
  • Measurement range: IXA1R: 0-360 degrees, IXA2R: ±10, ±30, ±60 degrees.
  • Power supply: +7Vdc to +30Vdc, with a maximum power consumption of 30 mA.
  • EMC compliance: EN 61000-6-2, EN 61000-6-3.
Mechanical Specifications:
  • Housing material: Die-cast aluminium alloy.
  • Electrical connections: Single 12-wire cable, 1 m standard, with additional cable options.
Environmental Specifications:
  • Shock resistance: 300 g, 11 ms according to EN60068-2-27.
  • Vibration resistance: 8.2-500 Hz, 40 m/s² according to EN60068-2-6; 10-500 Hz, 3 g according to EN60068-2-64.
  • Operating and storage temperature range: -40°C to +85°C (-40°F to +185°F).
Ordering Information:
  • IXA1R (1-axis version) and IXA2R (2-axes version) with options for output type, measuring range, and cable length.
See more

Catalog excerpts

TILTCOD IXA1R,IXA2R-1

TILTCOD LINEPULS Analogue output inclinometers Magnetic sensor with integrated converter Series •  Redundant inclinometer, double sensor & output circuit •  Analogue voltage or current output •  1 axis operation, 0-360 deg •  2 axes operation, ±10 / ±30 / ±60 deg •  Measurement accuracy ±0.2 deg •  Robust metal housing with IP67 protection ENVIRONMENTAL SPECIFICATIONS Shock: Vibrations: Protection: Operating temperature range: Storage temperature range: MECHANICAL SPECIFICATIONS Dimensions: Housing material: Electrical connections: Options: see drawing die cast aluminium alloy single 12-wire cable, 1 m additional cable ELECTRICAL SPECIFICATIONS Resolution: Accuracy: MTTF values for each output channel: Temperature drift: Measurement range: Output circuit: Power supply: Power consumption: Protection: EMC: 0,05% of measurement range typ. ±0,2 deg (max. ±0,5 deg) only up to ±30° for 2 axes

 Open the catalog to page 1
TILTCOD IXA1R,IXA2R-2

Order code - 1 axis version IXA1R L1 = cable 1 m (standard) Lx = cable x m (length on request) Order code - 2 axes version IXA2R L1 = cable 1 m (standard) Lx = cable x m (length on request) d custom version Specifications subject to changes without prior notice

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.