Spindle jacks
60Pages

{{requestButtons}}

Catalog excerpts

Spindle jacks - 1

with trapezoidal screw or ball screw Program Design and calculation criteria haacon hebetechnik gmbh Josef-Haamann-Str. 6 D-97896 Freudenberg/Main Tel: + 49 (0) 93 75/84-0 Fax: + 49 (0) 93 75/84-86 e-mail: hebetechnik@haacon.de Internet: http://www.haacon.com

Open the catalog to page 1
Spindle jacks - 2

Competence in lifting technology

Open the catalog to page 2
Spindle jacks - 3

haacon haacon haacon haacon haacon is a company in the mechanical lifting field with comprehensive experience in manufacturing and marketing of spindle jacks. With these catalogue we have made it easy to select a screw jack or screw jack system suitable for your application. You can also consult our Technical Sales department. They will help you with computer calculations and suggestions, for both standard and special applications. Being an international company, we are able, through our own subsidiaries and active agents, to give the optimum solution, on a local basis. Introduction HN/HQ...

Open the catalog to page 3
Spindle jacks - 4

Competence in lifting technology Standard Executions Standard Executions Execution Execution Execution 1111 Execution Execution 1 BDL Screw jack with Lifting nut BDL Screw jack with Lifting nut BDL Screw jack with Lifting nut Screw jack withBDL Screw jack with Lifting nut Lifting nut BDL Screw jack with Lifting nut BD Screw jack with Translating Lifting screw Screw jack BD Screw jack with Translating Lifting screw with Translating Lifting Screw BD Screw jackScrew jack with Translating Lifting screw BD with Translating Lifting screw BD Screw jack with Translating Lifting screw Screw jack...

Open the catalog to page 4
Spindle jacks - 5

Variant & Special Executions Variant Executions LR Locked against rotation LRK Locked against rotation ABL Antibacklash LR Locked against against rotation LR Locked rotation LRK Locked against against rotation LRK Locked rotation ABL Antibacklash ABL Antibacklash LR Locked against rotation rotation LRK Locked against rotationwith rotation ABL Antibacklash Antibacklash LR Locked against rotation LRK Lockedwith Keyrotation againstwith ABL LR LR Locked against rotation Locked against LRK Locked againstwithKey Key rotation ABL Antibacklash LRK Locked against key ABL Antibacklash with with Key...

Open the catalog to page 5
Spindle jacks - 6

Competence in lifting technology LIFTING SCREW Axial lifting spindle  LOAD SPECIFICATION Mounting position of screw: horizontal  upwords  inverted  Screw end: Thread  Top plate  Clevis  Spindle protection: Tube on reverse side: yes  Spindle material: Steel  Safety nut: yes  no  (Mandatory, if people stay under suspended load) Anti backlash: Limit switch: Stainless steel case: yes  Environment:  dusty  humid  corrosive MOTOR DATA

Open the catalog to page 6
Spindle jacks - 7

haaconSelection Guide Please add sketch:

Open the catalog to page 7
Spindle jacks - 8

Competence in lifting technology Screw jack LS Limit switches Tele mecanique MLS Magnetic Limit switches Fork End (special) Road End Clevis End Lifting Screw a. Standard Single start b. Double start c. Locked against Rotation (keyed) d. Stainless Steel e. Left hand threaded Bellows a. PVC b. Hypalon c. Special Base Unit LR LR Locked against rotation Locked against rotation a. Standard b. Safety Nut c. Locked against Rotation (Keyed) d. Anti-Backlash Screw Jack with worm gear motor Double Clevis Ends (with Reinforced Protection Tube) Steel a. Steel b. St. St. Shaft Protection Hand Wheel...

Open the catalog to page 8
Spindle jacks - 9

Determination of type Direction of rotation Translating screw (upright) Rotating screw with lifting nut (upright) Translating screw (inverted) Note: For types HN/HQ and HK spindle must be held to prevent rotation. Rotating screw with lifting nut (inverted) For types HNL/HQL and HKL lifting nut must be held to prevent rotation.

Open the catalog to page 9
Spindle jacks - 10

Selection of jacks Symbols used: F = Force (N) (1 tonne = 10 000 N) v = Lifting speed (mm/min) s = Pitch of lifting screw (mm) n = input speed (rpm) i = Ratio of worm gear set ED = Intermittence factor (%) Pd = Running power of screw jack (kW) Ps = Starting power of screw jack (kW) PED = Thermal power (kW) PMnom = Nominal motor power (kW) PMst = Starting power of motor (kW) PMax = Max allowable input power of screw jack (kW) nd = Running efficiency of screw jack r|s = Starting efficiency of screw jack To calculate a screw jack you must at least know the force (F) to be moved and the...

Open the catalog to page 10
Spindle jacks - 11

haaconGuide to select single screw jack arrangements Single screw jack Load: 30 kN compression Stroke: 500 mm Loadcase: Euler II Intermittence factor: 15 min/hour Lifting speed: 415 mm/min Ambient temperature: 25° C 1. Select a screw jack where the nominal force is larger than the required force from table below: Load 30kN -> HQ 50: Max capacity for HQ 50 is 50 kN > 30 kN. 3. Selection of one screw jack. Calculate the running power (Pd) and starting power (Ps). These are stated in tables or can be calculated as follows: Pd = (F x v)/(r|d x 6 x 101 2 3) = (30 x...

Open the catalog to page 11
Spindle jacks - 12

Competence in lifting technology Guide to select multiple screw jack arrangements Lauter ton drive Screw jack arrangements Pre-step Helical Gear 1. Running power consummation for each screw jack = 0.77 kW according to calculation above. Starting power consummation for each screw jack = 1.48 kW according to calculation above. 2. Add the power- and starting consummation for each screw jack to get the total power- and starting consummation power Px and Pxst. For arrangement with 4 screw jacks: Px = 4 x 0.77 = 3.08 kW Pxst = 4 x 1.48 = 5.92 kW 3. Take consideration to the efficiency to the...

Open the catalog to page 12
Spindle jacks - 13

□ haaconDescription of trapezoidal lifting screw 1. Trapezoidal lifting screw 2. Thrust and radial bearings 4. Housing of nodular cast iron 5. Alkyd paint 85 micron thick in RAL 1234 6. Worm screw hardended and ground 7. Worm wheel of centrifugally cast tin bronze 8. Bellows in PVC, steel or other materials (without fig.) Mechanical jacks have a allowable working temperature range from -30° C to +100° C. At full load the degree of utilization (ED) must not normally exceed 40% per 10 minutes, still not more than 20% per hour totally, in valid at ambient temperature +25° C. For other...

Open the catalog to page 13
Spindle jacks - 14

Competence in lifting technology

Open the catalog to page 14
Spindle jacks - 15

haaconCompression load table trapezoidal lifting screw Euler I Max capacity (kN)

Open the catalog to page 15

All Lifting Products Ltd catalogs and technical brochures

  1. vhs_katalog

    70 Pages