BELLOWS SEALS LMB84 COMPONENTS: 1 Rotating contact surface 3 O-rings 4 Metal bellows. 5 Set screws 6 Metal frame CHARACTERISTICS: • Balanced. • Spiral-wound metal bellows. • Not dependent on the rotation direction. OPERATING LIMITS: d,= 18 - 100 mm p= 20 kg/cm! v= 25 m/s t= -40- +200°C (*) (*) The temperature resistance depends on the material of the secondary seals used. The operating limits are defined by the PV factor which is determined for the sealing system characteristics and those of the application. DESCRIPTION: Balanced by the bellows, without the need for a stepped shaft (models LWS10B, LMS20B). Suitable for working in applications with high pressures. The O-ring resting on the shaft does not cause wear as there is no axial movement (changes in pressure). Recommended for working with sticky or viscous fluids that require cleaning processes (CIP) or sterilisation processes (SIP) in situ due to the geometry of the spiral-wound bellows. This seal may be supplied with any of the stationary parts shown in pages 56 and 57. for measurements in mm, and 58 for the measurements in inches. DIMENSIONS CHART Dimensions in mm I Shaft I Rotary partDimensions in mm Shaft I Rotary part mm d3 d4 Dimensions subject to changes or modifications.
Open the catalog to page 1BELLOWS SEALS COMPONENTS: 1 Rotating contact surface 2 Stationary contact surface 3 O-rings 3a O-rings 4 Metal bellows CHARACTERISTICS: • Balanced. • Welded metal bellows. • Not dependent on the rotation direction. OPERATING LIMITS: d1= 16 - 100 mm p= 20 kg/cm! v= 25 m/s t= -40- +200°C -40+ +200 °C (up to 400° C with a special design) (*) (*) The temperature resistance depends on the material of the secondary seals used. The operating limits are defined by the PV factor which is determined for the sealing system characteristics and those of the application. DESCRIPTION: Internally balanced,...
Open the catalog to page 2BELLOWS SEALS LMB86 SECTORS: COMPONENTS: 1 Rotating contact surface 3 Graphite wedge 4 Metal bellows 5a Set screws 5b Tightening screw CHARACTERISTICS: • Balanced. • Graphite wedge • Welded metal bellows. • Not dependent on the rotation direction. OPERATING LIMITS: d,= 25 - 100 mm p= 20 kg/cm! v= 25 m/s t= -75- -4250C (*) (*) The temperature resistance depends on the material of the secondary seals used. The operating limits are defined by the PV factor which is determined for the sealing system characteristics and those of the application. DESCRIPTION : Internally balanced, with no need...
Open the catalog to page 3BELLOWS SEALS LRB00 SECTORS: COMPONENTS: 1 Rotating contact surface 2 Stationary contact surface 3 Bellows 3a Elastomeric cup 4 Spring 5 Ring 5a Drive ring 5 b Metal frame CHARACTERISTICS: • Balanced. • Not dependent on the rotation direction. • Single cylindrical spring. OPERATING LIMITS: d,= 9.52 -t-101.60 mm p= 14 kg/cm! v= 13 m/s t= -20- +200°C (*) (*) The temperature resistance depends on the material of the secondary seals used. The operating limits are defined by the PV factor which is determined for the sealing system characteristics and those of the application. DESCRIPTION: Mechanical...
Open the catalog to page 4BELLOWS SEALS COMPONENTS: 1 Rotating contact surface 2 Stationary contact surface 3 Bellows 3a Elastomeric cup 4 Spring 5 Ring 5a Drive ring 5b Metal frame DIMENSIONS CHART LRB00U Dimensions in inches DIMENSIONS CHART LRB00L Dimensions in inches Rotary part Total length Stationary part Total length Dimensions subject to changes or modifications. Dimensions subject to changes or modifications.
Open the catalog to page 5BELLOWS SEALS CHARACTERISTICS: • Unbalanced. • Not dependent on the rotation direction. • Single cylindrical spring. (*) The temperature resistance depends on the material of the secondary seals used. The operating limits are defined by the PV factor which is determined for the sealing system characteristics and those of the application. DESCRIPTION: Mechanical seal with a simple design for general use. Type LRB04/ LRB04A are standardised models in accordance with EN 12756 (KU). DIMENSIONS CHART LRB01 Dimensions in inches DIMENSIONS CHART LRB01S Dimensions in inches Rotary part Stationary part...
Open the catalog to page 6BELLOWS SEALS DIMENSIONS CHART LRB04 / LRB04A Dimensions in mm Dimensions subject to changes or modifications. DIMENSIONS CHART LRB06 Dimensions in mm Total length Dimensions subject to changes or modifications.
Open the catalog to page 7BELLOWS SEALS COMPONENTS: 1 Rotating contact surface 2 Stationary contact surface 3 Bellows 3a Elastomeric cup 4 Spring 5 Metal frame CHARACTERISTICS: • Unbalanced. • Not dependent on the rotation direction. • Single cylindrical spring. OPERATING LIMITS: d1= 9.52 - 25.40 mm p= 7 kg/cm! v= 10 m/s t= -15- +200°C (*) (*) The temperature resistance depends on the material of the secondary seals used. The operating limits are defined by the PV factor which is determined for the sealing system characteristics and those of the application. DESCRIPTION: Seal with a compact design for applications...
Open the catalog to page 8BELLOWS SEALS CHARACTERISTICS: • Unbalanced. • Not dependent on the rotation direction. • Single cylindrical spring. OPERATING LIMITS: d1= 10 - 30 mm p= 6 kg/cm! v= 10 m/s t= -20- +100oC (*) (*) The temperature resistance depends on the material of the secondary seals used. The operating limits are defined by the PV factor which is determined for the sealing system characteristics and those of the application. DESCRIPTION: Mechanical seal with a compact design and small dimensions which is ideal for simple hydromassage or drinking water pumps. The rotating part is attached to the pump impeller, rotates...
Open the catalog to page 9Shaft Rotary part Stationary part Dimensions subject to changes or modifications.
Open the catalog to page 10BELLOWS SEALS COMPONENTS: 1 Rotating contact surface 2 Stationary contact surface 3 Bellows 3a Elastomeric cup 4 Spring 5 Ring 5a Drive ring 5 b Metal frame CHARACTERISTICS: • Unbalanced. • Not dependent on the rotation direction. • Single cylindrical spring. OPERATING LIMITS: d1=12 - 25.4 mm p= 7 kg/cm! v= 10 m/s t= -20- +100°C (*) (*) The temperature resistance depends on the material of the secondary seals used. The operating limits are defined by the PV factor which is determined for the sealing system characteristics and those of the application. DESCRIPCION: Mechanical seal with a simple...
Open the catalog to page 112 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
8 Pages
2 Pages
8 Pages
2 Pages
3 Pages
7 Pages
3 Pages
9 Pages
6 Pages
12 Pages
84 Pages
1 Page
1 Page
1 Page
12 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
16 Pages