1. Product Characteristics
  • Temperature Range: -30º C to +110º C
  • Working Pressure: 30 bar
  • Volume: 2 liters
  • Flow Rate: 15 ml per run-out
  • Materials: Stainless steel and polyethylene
2. LHP Description

The LHP is equipped with a built-in tank designed for placement on the reservoir, installed directly in the LTS reservoir. It operates at a working pressure of 64 bar and can withstand temperatures up to 125º C. The primary material used is stainless steel.

3. Cyclone Functionality

Working fluids often contain particles that can damage mechanical seals. A cyclone is installed outside the pump to separate these particles using centrifugal force, ensuring clean fluid returns to the mechanical seal chamber. This system requires no maintenance and is resistant to blockage.

4. Ring Attachment

A ring with two allen screws is used to attach to the shaft, ensuring the compression of the rotating part of the mechanical seal. It is compatible with rubber bellows or single spring mechanical seals.

5. LST Characteristics
  • Temperature Range: -60º C to +200º C
  • Working Pressure: Up to 25 bar
  • Volume Options: 4, 6, 10 liters
  • Materials: Stainless steel

The LST supplies barrier fluid in mechanical seal installations, utilizing the thermosyphon effect or a pumping ring. It can be configured with API52, API53, and API53A standards and may include instruments for automatic control and a cooling coil.

6. Dimensions Chart

A detailed dimensions chart is provided, listing various shaft sizes and corresponding measurements in millimeters.

See more

Catalog excerpts

AUXILIARY PRODUCTS-1

AUXILIARY PRODUCTS CHARACTERISTICS: • Working pressure: 64 bar. • Temperature: up to 125º C • Materials: Stainless steel. CLEAN FLUID DESCRIPTION: SEALED CHAMBER PUMP DISCHARGE ZONE Working fluids often contain sand particles, incrusted residue from boilers and pipes etc. which can damage the mechanical seal and reduce its durability. Situations of this type can be avoided by installing a cyclone. This type of element is installed outside the pump, between the discharge zone and the mechanical seal chamber. A current or vortex of pressurised fluid is generated inside it and the effect of the centrifugal force separates the particles suspended in the fluid. The particles that are heavier than the fluid are thrown towards the walls and dragged to the lower part of the LC, while the clean fluid emerges from the top and is returned to the chamber where the mechanical seal is located. API31 and API41 configuration. These elements require no maintenance and do not become blocked over time. CHARACTERISTICS: • Temperature: - 30º C to +110º C. • Working pressure: 30 bar. • Volume (L) : 2 l. • Flow rate: 15 ml / run-out • Materials: Stainless steel / polyethylene. DESCRIPTION: LHP with a built-in tank for placing on the reservoir. Installed directly in the LT

 Open the catalog to page 1
AUXILIARY PRODUCTS-2

LQT SECTORS: CHARACTERISTICS: • Temperature: -60° C to +200° C. • Working pressure: up to 25 bar. • Volume: 4, 6, 10 l. • Materials: Stainless steel. DESCRIPTION: LST for supplying barrier fluid with or without pressure in double cartridge or mechanical seal installations which enables the circulation of the barrier fluid due to the thermosyphon effect or the pumping ring (mechanical seal). API52, API53 and API53A configuration. SECTORS: DIMENSIONS CHART Dimensions in mm CHARACTERISTICS: • Ring with two allen screws for attaching it to the shaft. DESCRIPTION: This element is attached to the shaft...

 Open the catalog to page 2
AUXILIARY PRODUCTS-3

AUXILIARY PRODUCTS LST CARACTERISTIQUES : • Temperature: -60° C to +200° C. • Working pressure: up to 25 bar. • Volume: 4, 6, 10 l. • Materials: Stainless steel. DESCRIPTION : LST for supplying barrier fluid with or without pressure in double cartridge or mechanical seal installations which enables the circulation of the barrier fluid due to the thermosyphon effect or the pumping ring (mechanical seal). API52, API53 and API53A configuration. It may be supplied with instruments for automatic level, pressure and temperature control and verification and a cooling coil to regulate the fluid barrier...

 Open the catalog to page 3

All LIDERING catalogs and technical brochures

  1. SEAT SHAPE

    3  Pages

  2. BELLOW

    18  Pages

  3. WAVE SPRING

    6  Pages

  4. MULTI-SPRING

    12  Pages

  5. CARTRIDGES

    84  Pages

  6. LS40C

    1  Page

  7. Lsc39-FQ

    1  Page

  8. Flat gaskets

    12  Pages

  9. LMS11

    1  Page

  10. LS

    1  Page

  11. LST-LHP

    1  Page

  12. LC-LQT

    1  Page

  13. LDC40

    1  Page

  14. LDC21

    1  Page

  15. LDC22-F

    1  Page

  16. LDC39-D

    1  Page

  17. LDC38

    1  Page

  18. LDC80

    1  Page

  19. Kitting

    1  Page

  20. LSC40-F

    1  Page

  21. LSC211A

    1  Page

  22. LSC211

    1  Page

  23. LSC21

    1  Page

  24. LSC22

    1  Page

  25. LSC39-F

    1  Page

  26. LSC39 FQ

    1  Page

  27. LSC38

    1  Page

  28. LSC50-F

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.