JF-2500 Model X-Ray diffractometer Dandong Liaodong Radioactive Instrument Co.,Ltd 址:辽宁省丹东市振安区同兴镇兴园街 9 号 话:0415-2155887 址:www.ld-ray.com www.fxyqc.com 第 1 页 共 9 页
Open the catalog to page 1Main Technical Parameter 1. X-Ray Tube (1) X ray tube type: ceramic or glass tube is optional; Target material with European standard interchangeable; (2) the type of target: Cu, Fe, Co, Cr, Mo, Ti, W is optional; (3) the factory standard configuration: Cu; (4) size: 1 x 10 mm; (5) the rated power: 2.4 KW. 2. X Ray high frequency high voltage generator (1) the X-ray tube voltage: 10 to 30 kV or 10 to 40 kV (2) X-ray tube current: 5 to 20 mA, or 5-30 mA (3) the filament current: DC: 0-3 A. (4) stability: plus or minus 0.001% (10%) power supply voltage fluctuation; (5) the maximum output...
Open the catalog to page 2Scintillation counter: (1) the maximum linear count rate: 1 x 106 CPS/s; (2) spectral resolution: less than 50% ; (3) the counter pressure: 0-2100 V adjustable; High voltage stability is better than 0.005% (2) the circulating water flow: 3 L/min. (4) the system temperature setting range: 18 to 30 °, the temperature control precision: plus or minus 1 ° (5) panel display lamp: power supply, refrigeration, flow detection; 6. dimension and weight (1) dimension: 720 (length) x 550 (width) x 630 mm (high); (2) weight: 75 kg; R i±: www. ld-ray. com www. fxyqc. com
Open the catalog to page 38. X ray diffractometer spare parts Item Blind hole glass powder sample (trace 3 pieces) Glass plate hole powder sample The zero block gauge Oil tank "O"Type of rubber gasket 3A The fuse Fluorescent board Combination of tools Agate mortar 址:辽宁省丹东市振安区同兴镇兴园街 9 号 话:0415-2155887 址:www.ld-ray.com www.fxyqc.com 第 4 页 共 9 页
Open the catalog to page 4JF serises X ray diffractometer software database analysis manual JF-series X-ray diffractometer software system consists of two parts, data acquisition software and application software packages, including main data collection, data acquisition software and application software package is used to analyze the diffraction data system, so as to achieve the purpose of the analysis. 1.Data acquisition software package Data acquisition software contains the following features: (1). Automatic control of X-ray diffractometer, including X-ray generator, goniometer rotation. (2). Combined with...
Open the catalog to page 5fitting the peak (real) and grain size; Alpha 1, alpha 2 K stripping: K alpha 2 stripped clean, for to process the data file contains only alpha 1 K, Smooth: set smooth points, choose a smooth way, including full spectrum is smooth, smooth, smooth background only adjust peak, etc.; Any range of peak shape: a spectrogram, through the mouse left key to arbitrary multiple spectra of zoom in and out; Figure correction: by the mouse buttons to chromatogram peak delete redundant, and the loss of peak add; Multiple drawing: open at the same time a number of data files, both can be treated...
Open the catalog to page 63.Other function:Including linear analysis, determination of cell, 2 kinds of stress calculation, the diffraction lines index, etc 4.Print the data processing results All data processing can be print, print can be done before the preview and modify, such as: will open another window, weak peak shape local up, add text annotation, select print format, etc. 5.The qualitative analysis Adopt the internationally used database (group 1-- 57), either for card queries, and can automatically retrieval and manual retrieval, automatic search results include: card number, formula (or mineral), matching...
Open the catalog to page 76. Contrast function It can open up to more than 10 maps and 3 D comparison, a variety of functions such as map tile contrast comparison, to show the change of the same sample at different temperature. Data processing software, connected to a Windows to mark will output the map, paste, amplification, narrow, and other functions, can also be image into the clipboard, in Word or Excel paste directly. 7. quantitative analysis Adopting quantitative analysis sample, using the full spectrum fitting method, the crystal structure ICSD database Calculate the main phase, a small amount of phase, the...
Open the catalog to page 88. Full spectrum fitting analysis of polycrystalline structure (WPF) Full spectrum linear fitting for crystal structure refinement, parsing, crystal structure, not only can study polycrystalline, Aggregate structure, but also can study the crystal microstructure, if there are impurities in the crystal, Defects such as dislocations, grain boundaries, lattice distortion. Accurate qualitative analysis of the sample, accurate without calibration Content analysis. 9.Diffraction spectra simulation According to the material atoms spatial arrangement structure, simulation generated X-ray...
Open the catalog to page 9All Liaodong Radioactive Instrument catalogs and technical brochures
-