Product catalog summary
Applications
  • Calibration Laboratories
  • Testing Labs
  • Universities/R&D
  • Pharmaceutical/Biotech Industry
  • Food Industry
Highlights
  • Quick and easy setup
  • External reference reading
  • Reading sensor values
  • Automatic calibration and adjustment
  • Remote access
  • Monitoring room conditions
  • Clean and reliable humidity generator
  • Controller algorithm
  • Calibrated sensors
  • Color touch screen
  • Connectivity
General Information
  • Compact device for on-site calibration, ideal for field calibrations
  • Relative humidity uncertainty with 95% confidence is typically 0.5 to 1.2%
  • Temperature range: -10°C to +60°C
  • RS232 input on the back
  • Up to 6 probes can be calibrated simultaneously in its temperature-controlled chamber
  • Fast response, high stability, avoiding condensation formation
  • Supports up to 6 round cross-section probes, with a maximum diameter of 25 mm
  • The adjustment process is completely automatic with IMS4 software (not included)
  • Remote access and monitoring room conditions
  • 5-inch color touch LCD screen
Technical Specifications
  • Temperature range: -10°C to +60°C
  • Environmental temperature: 10 to 35ºC
  • Humidity Range: 0.1ºC (5 to 95) %RH
  • Relative ambient humidity: < 80 % HR
  • Humidity feedback sensor: Solid State Capacitive Polymer
  • Humidity Stability: Better than 0.1% RH
  • Temperature Stability: Better than 0.05ºC
  • Resolution Humidity: 0.01% HR
  • Condensation Prevention Algorithm: Yes
  • Consumables: Desiccant (molecular sieve), distilled water
  • Total chamber volume: 2.5 liters
  • Diameter and usable depth of the chamber: 140 millimeters
  • Chamber Homogenization: Variable speed fan
  • Calibrated Sensors: 6
  • Maximum calibrated sensor diameter: 25 mm
  • Humidity Generation: Mixed Flow
  • Temperature Generation: 4 Peltier thermoelectric cells
  • Warm-up time: 6 minutes
  • Cooling time: 42 minutes
  • Communication port: RS-232
  • Calibrated Sensors analog voltage: 0 to 2.5V, SDI12, 5V UART
  • Remote Communication: Ethernet RS-232
  • Protocol: ASCII
  • Supply voltage: 100 to 240 VAC
  • Maximum Power: 320 Volts
  • Equipment Dimensions (W x D x H): 350x240x430mm
  • Weight: 13Kg
  • Carrying case dimensions: 510x350x620mm
  • Carrying case weight: Approx 10 Kg
  • Consumption Power: Approx. 1,200 W
Uncertainty Calculations
  • Relative Humidity Uncertainty at various temperatures and humidity levels
  • Temperature uncertainty at various temperatures
Standard Delivery
  • Relative humidity calibrator with options
  • Relative humidity control range: 10…90%
  • Temperature control range: 10°C to 50°C
  • Standard door
  • Desiccant cartridge for Humical
  • RH+T calibrated control probe with 3.1 certificate
  • Instruction manual
  • Includes 6 blanking stops, 6 port adapters for calibrated sensors
Optional Accessories
  • Impact resistant transport trolley case
  • RH extended range (5%­95%)
  • Temperature extended range (0..60) °C
  • Temperature extended range (-10..60) °C
  • Water level indicator
  • Desiccant status indicator
  • Read out card for 6 probes
  • Cable to connect readout card to Humical
  • Set converters for 1 channel of readout card to RS-232 and RS-485
  • Ambient Monitor
  • Relative humidity and temperature probe RH 175
  • Cable with Fischer connector to connect RHT175 to Humical
  • Atmospheric pressure sensor MSB181
  • Cable with Fischer connector to connect MSB181 to Humical
  • Molecular sieve desiccant 0.9 kg
  • Spare desiccant cartridge for Humical
  • Spare control RH probe for Humical
  • Spare port adapter for sensor port diameter
  • Special spare port adapter for sensor port diameter
  • Spare port adapter for Reference port
  • Spare standard door with 6 + 1 ports
  • Transparent door with double acrylic glass without ports
  • Transparent door with double acrylic glass with 30 mm
  • Door for MBW 473 RP2 and one 32 mm port for standard probe adapter
  • IMS4 CalibLab for RhT - software license
  • Implementation of a new sensor type
  • Customized spreadsheet report for IMS4 CalibLab
See more

Catalog excerpts

Humical-1

Humical The Humical Relative Humidity Calibrator is designed to work with chilled mirror reference hygrometer to provide the highest possible accuracy. The relative humidity uncertainty with 95% confidence is typically 0.5 to 1.2% at near ambient temperature. The temperature range of 10°C to +60°C makes Humical the Most powerful humidity calibrator in its class. With more cooling power, the setpoint is reached faster. It is suitable for temperature/humidity and temperature cycles APPLICATIONS Calibration Laboratories Testing Labs Universities/ R&D Pharmaceutical/ Biotech Industry Food Industry HIGHLIGHTS Quick and easy setup External reference reading Reading sensor values Automatic calibration and adjustment Remote access Monitoring room conditions Clean and reliable humidity generator Controller algorithm Calibrated sensors Color touch screen Connectivity General information Compact device for onsite calibration (ideal for field calibrations) Relative humidity uncertainty with 95% confidence is typically 0.5 to 1.2% Temperature range 10°C to +60°C RS232 input on the back Up to 6 probes can be calibrated simultaneously in its temperaturecontrolled chamber Fast response, high stability, avoiding condensation formation Supports up to 6 round crosssection probes, with a maximum diameter of 25 mm The adjustment process is completely automatic with IMS4 software (not included) Remote access Monitoring room conditions 5inch color touch LCD screen

 Open the catalog to page 1
Humical-2

Technical Data Temperature range Environmental temperature Humidity Range Relative ambient humidity Humidity feedback sensor Humidity Stability Temperature Stability Resolution Humidity Algorism Condensation Prevention Consumables Total chamber volume Diameter and usable depth of the chamber Chamber Homogenization Calibrated Sensors Maximum calibrated sensor diameter Humidity Generation Temperature Generation Warm-up time Cooling time Communication port Calibrated Sensors Remote Communication Protocol Supply voltage Maximum Power Equipment Dimensions W x D x H (cm) Weight (kg) Carrying case dimensions...

 Open the catalog to page 2
Humical-3

Temperature gradient according to IEC 60 068-3-11:2007 Humlwell cllmatogram Cooling time according to EC 60068-3-5: 2001 Standar Delivery Relative humidity calibrator with these options Relative humidity control range 10...90% Temperature control range from 10°C to 50°C *Standard door Desiccant cardridge for Humical RH+T calibrated control probe with 3.1 certificate. Instruction manual *Includes 6 blanking stops, 6 port adapters for calibrated sensors - standard diameters to choose from (12mm, 15mm, 18.5mm, HMP155)

 Open the catalog to page 3
Humical-4

Optional Impact resistant transport trolley case RH extended range (5%95%) Temperature extended range (0..60) °C Temperature extended range (10..60) °C (includes range 0..60) °C Water level indicator Desiccant status indicator Read out card for 6 probes (0..2,5 V analog, UART, SDI12) Cable to connect readout card to Humical Set converters for 1 channel of readout card to RS232 and RS485 Ambient Monitor (including RHT175 probe, MSB181 Relative humidity and temperature probe RH 175 Cable with Fischer connector to connect RHT175 to Humical Atmospheric pressure sensor MSB181 Cable with Fischer connector...

 Open the catalog to page 4