Group: Atlas Copco
Catalog excerpts
Directive 94/9/EG (ATEX 95) Technical Information 100.90.02
Open the catalog to page 1Vacuum Pump Type Overview and Classification* Type Model / Line Classification inside (i) outside (o) TRIVAC B, Cat. 3(i) II (i) 3G IIC T4 (50 Hz) II (i) 3G IIC T3 (60 Hz) B, Cat. 3(i/o) II (i) 3G IIC T4 (50 Hz) (o) 3G IIC D 16 B ATEX, 1(i)/2(o) II (i) 1G IIB3 T4 (50 Hz) (o) 2G IIB T4 II (i) 1G IIC (no C2H2, CS2) T4 (50 Hz) (o) 2G IIC T4 SOGEVAC SV40 ATEX IIA II (i)1G IIA T3 (o) 2G IIA T3 SV40 ATEX IIB + H2 II (i)1G IIB+H2 T4 (50 Hz) (o) 2G IIB+H2 T4 II (i)1G IIB+H2 T3 (160 °C) (60 Hz) (o) 2G IIB+H2 160 °C SV B ATEX Cat.3 II (i) 3G IIC T3 (o) 3GD IIC T3 RUVAC WA/WAU II (i) 3G IIC T3 II (i)...
Open the catalog to page 2SOGEVAC SV 300 ATEX TRIVAC ATEX The inside and outside of the pump complies with the basic safety requirements of the EU Directive 94/9/EG. For special requirements, the TRIVAC D 16 B ATEX is available for use in explosion hazard zone 1. TRIVAC D 16 B ATEX Flame arresters on the inlet and outlet sides Pressure monitoring by a pressure sensor Temperature monitoring on the inlet and outlet sides Explosion-proof design of housing and motor Flame arresters on the inlet and outlet sides Pressure sensor to monitor the pressure in the oil housing Pt100 temperature sensor for vacuum generator...
Open the catalog to page 3The RUVAC Roots pumps WA/WAU can optionally be equipped with a temperature monitoring facility (Pt 100 temperature sensor) ATEX compliant pump system with SOGEVAC SV 300 and RUVAC WAU 1001 Screw Pumps SCREWLINE SP The screw pumps from the lines SCREWLINE SP250 ATEX and SP630 ATEX comply with Category 3 (inside) respectively 2 inside and 3 outside. These pumps comply with the basic safety requirements laid down in ATEX Directive 94/9/EG. As standard, all SCREWLINE ATEX pumps are equipped with a barrier gas control unit.
Open the catalog to page 4Explosive Zone* Category* Probability that atmosphere the pump is an ignition source Constant, No ignition source, long-term or 0 1 even not in the frequently event of rare present malfunctions To be expected No ignition source, from time to 1 2 also in case of time malfunctions Rarely, and No ignition source even if present 2 3 during normal then only briefly operation Gas group IIC Type of explosive atmosphere: gas or vapor Category 2 outside, i.e. in the vicintiy of the pump (installation location) Category 1 inside, i.e. within the pump (process area) Equipment group II, i.e. not suited...
Open the catalog to page 5Headquarter Germany Oerlikon Leybold Vacuum GmbH Bonner Strasse 498 D-50968 Cologne T +49 (0) 221-347-0 F +49 (0) 221-347-1250 info.vacuum@oerlikon.com www.oerlikon.com 1. There is an explosive atmosphere (no mining applications) (i) within the pump (o) outside the pump Please state for each of the following the explosive atmosphere. 2. Zone (ignitable atmosphere) (i) (o) 0 Danger constant, long-term, frequent 1 Danger from time to time 2 Rare danger 4. Temperature class (maximum desired surface temperature of the operating agent) (i) (o) T1 up to 450 °C max. T2 up to 300 °C max. T3 up to...
Open the catalog to page 6All Leybold catalogs and technical brochures
-
Full Line Catalog
1046 Pages
-
GRAPHIX Series
2 Pages
-
DRYVAC Energy Saver
2 Pages
-
DRYVAC PowerBoost
8 Pages
-
DRYVAC SERIES
5 Pages
-
Mechanical Vacuum Systems
8 Pages
-
Renewable Energies
6 Pages
-
Coating Technologies
8 Pages
-
Fundamentals of Vacuum Technology
200 Pages
-
Product Overview 2019
24 Pages
-
Fundamentals of leak detection
49 Pages
-
Vacuum Pumps
6 Pages
-
SmartCheck
4 Pages
-
LEYASSIST
2 Pages
-
Ion Getter Pumps
6 Pages
-
Vacuum Measurement - Sensors
8 Pages
-
PHOENIX 4 Leak Detector
8 Pages
-
Multi Inlet TURBOVAC i
8 Pages
-
SOGEVAC NEO
8 Pages
-
Food & Packaging
36 Pages
-
Product Overview 2018
24 Pages
-
Full Line Catalogue 2018
980 Pages
-
COMBIVAC Series
2 Pages
-
PHOENIX Series
8 Pages
-
COOLPOWER
2 Pages
-
DIJ - Oil Diffusion Pumps
4 Pages
-
RUVAC® WH / WHU Roots Pumps
8 Pages
-
DRYVAC Systems
6 Pages
-
CVS Central Vacuum Stations
4 Pages
-
CLAWVAC
6 Pages
-
VACUBE
12 Pages
-
ECODRY plus
8 Pages
-
TRIVAC T
6 Pages
-
Oil Sealed Vacuum Pump
194 Pages
-
Cryogenics
8 Pages
-
Rotary Vane Pumps
8 Pages
-
Flat Panel Display
12 Pages
-
Research & Development
12 Pages
-
Coating Applications
8 Pages
-
TURBOVAC i
12 Pages
-
SOGEVAC SV 16 - 25 D
2 Pages
-
SOGEVAC SV 10 B - SV 120 B
4 Pages
-
SOGEVAC SV 300 B
4 Pages
-
COOLVAC
6 Pages
-
Turbomolecular Pump System
6 Pages
-
UNIVEX
8 Pages
-
Diffusion Pumps
4 Pages
-
TURBOVAC iX
12 Pages
-
Fluid entrainment pumps
8 Pages
-
MAG digiLine
4 Pages
-
RUVAC WA(U) / WS(U)
4 Pages
-
SOGEVAC SV10 B - SV 120 B
4 Pages
Archived catalogs
-
PHOENIXL 300
6 Pages
-
Oil-free Scroll Vacuum Pumps
4 Pages