LIGHTNING AND SURGE PROTECTION
220Pages

{{requestButtons}}

Catalog excerpts

LIGHTNING  AND  SURGE PROTECTION - 1

lightning and surge protection

Open the catalog to page 1
LIGHTNING  AND  SURGE PROTECTION - 2

Leutron Main Catalogue 2016 We reserve the right to make alterations in style and form in line with technical developement. The illustrations are non-binding. We do not assume liability for mistakes of printing errors. Reprint, even in extracts, only with approval of the Leutron GmbH. © Leutron GmbH 2015, 2nd Edition 11/2015. P/nN 98 01 86

Open the catalog to page 2
LIGHTNING  AND  SURGE PROTECTION - 3

Surge protection for power supply systems 2 AC Combined arrester type 1 + 2 + 3 (class I+II+III). . . . . . . . Selection guide PowerPro. . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPD type 2 (class II) for AC power supplies. . . . . . . . . . . . . . . Selection guide EL series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . AC Lightning current arrester type 1 (class I). . . . . . . . . . . . . . SPD type 3 (class III) for AC power supplies. . . . . . . . . . . . . . . DC Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Arresters for...

Open the catalog to page 3
LIGHTNING  AND  SURGE PROTECTION - 4

Surge protection with a new design The multi-pole combined modular arresters for protection against lightning strikes and transient surge voltages now have an even more attractive design. In addition to their outstanding technical properties, they are pluggable and provide a clearly readable function control indication and status display. The variable installation position – the base part can be plugged in two directions – enables a flexible and cost-saving wiring. Easy setup, secure operation: n New: Easy changing of the protection module thanks to a twopart design with a...

Open the catalog to page 4
LIGHTNING  AND  SURGE PROTECTION - 5

Surge protection for power supply systems The new design developed together with product design specialists allows for an easier handling. surge protection for power supply systems Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de

Open the catalog to page 5
LIGHTNING  AND  SURGE PROTECTION - 6

Two-piece pluggable surge protective devices for AC power supply systems New product line »Leutron Power«: Powerful and standardized pluggable modules for almost every power supply system available. n Optimized follow-on current extinguishing capability Mechanical status indicator: State of the surge protective device is optically indicated Locking function: Release of the latches by ergonomically shaped grip lugs Protection against mismating: Optimized installation due to arresters with coding Remote signalling: Combined remote contact (changeover contact) optionally available Turnable...

Open the catalog to page 6
LIGHTNING  AND  SURGE PROTECTION - 7

surge protection for power supply systems Two-piece pluggable surge protective devices for DC power supply systems Mechanical status indicator: State of the surge protective device is optically indicated Arrester elements available for 600 V and 1,000 V applications Safety for PV installations: Disconnection function in case of overloads optimized for photovoltaic systems Remote signalling: Combined remote contact (changeover contact) optionally available Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de

Open the catalog to page 7
LIGHTNING  AND  SURGE PROTECTION - 8

Network Type Adequate SPD circuit Type Basic circuit diagram 3 phase power supply systems separated N and PE 3 phase power supply systems 3 phase power supply systems separated N and PE 3 phase power supply systems common PEN 1 phase power supply systems 1 phase power supply systems separated N and PE 1 phase power supply systems L/N to PE Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0

Open the catalog to page 8
LIGHTNING  AND  SURGE PROTECTION - 9

selection guide Spur wiring / V-wiring product example PowerPro Combined arrester Type 1+2 (V wiring) PowerPro BC at the LPZ transition point OA-2* Lightning current arrester Type 1, PowerPro B at the LPZ transition point 0A – 1* Combined arrester Type 1+2+3 PowerPro BCD at the LPZ transition point OA-2* * according to the lightning protection zones concept Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.d

Open the catalog to page 9
LIGHTNING  AND  SURGE PROTECTION - 10

Network Type Adequate SPD circuit Type 3 phase power supply systems separated N and PE 3 phase power supply systems 3 phase power supply systems separated N and PE 3 phase power supply systems common PEN 1 phase power supply systems 1 phase power supply systems separated N and PE 1 phase power supply systems L/N to PE Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 947

Open the catalog to page 10
LIGHTNING  AND  SURGE PROTECTION - 11

selection guide Spur wiring / V-wiring product example EL Series SPD Type 2 (class II), Spur wiring at the LPZ transition point OB-1* SPD Type 2 (class II), V wiring at the LPZ transition point OB-1* F1 * according to the lightning protection zones concept Leutron GmbH · Humboldtstrasse 30 · 70771 Leinfelden-Echterdingen · Germany · Phone +49 711 94771-0 · www.leutron.de

Open the catalog to page 11
LIGHTNING  AND  SURGE PROTECTION - 12

Surge protection for power supply systems AC power supply Lightning current arrester Type 1 for AC power supplies / CT Series Example photo CT-T1 Lightning current discharge arrester (class I) with rare-gas-filled spark gap. They provide extremely high discharge cappabilities with at the same time very low protection levels and they also do not need any damageable internal or external electronic trigger. L1 Basic circuit diagram n Applicable at the boundaries LPZ 0A - 1 n standard: IEC 61643-1 / EN 61643-11 Test n Vibration and Shock according standard: DIN EN 60068-2-6 and DIN EN...

Open the catalog to page 12
LIGHTNING  AND  SURGE PROTECTION - 13

Surge protection for power supply systems AC power supply Technical Data Nominal voltage Max. continous operating voltage AC Lightning impulse current (10/350) total Lightning impulse current (10/350) L-N/N-PE/L-PEN Nominal discharge current (8/20) L-N/N-PE/L-PEN Follow current quenching capacity AC L-N (260V AC) Short-circuit withstand capability at max. back-up fuse Max. acceptable backup fuse (branch wiring) Max. acceptable backup fuse (V-type through wiring) Min. conductor cross section at terminals Max. conductor cross section Max. operating voltage remote contact Max. operating...

Open the catalog to page 13

All Leutron GmbH catalogs and technical brochures