Main Characteristics of TMRT TMCU
Mechanical Specifications:
  • Dimensions: TMRT - 360 x 160 x 100 mm; TMCU - 550 x 270 x 320 mm
  • Weight: TMRT - 4000 g ± 150; TMCU - 14000 g ± 350
  • Connectors: TMRT uses 0 halogen thermoplastic; TMCU uses circular metallic connectors
  • Fixation: By screw
  • Protection: IP67 rated
  • Toxic Fumes: 0 halogen (UL94-V0 norm), ensuring no toxic fumes
Power Supply:
  • Nominal Voltage: -52 Vcc
  • Maximum Error at Full Scale: +25%, -40%
  • Required Power on BT (without I/O): 10 to 45 W
  • First Protection: Includes polarity inversion and over voltage protection
Logic Inputs:
  • Number: TMRT - 16; TMCU - 96
  • Nominal Voltage: -52 Vcc
  • Incoming Current at Nominal Voltage: 20 mA
Logic Outputs:
  • Number: TMRT - 6 relays; TMCU - 0
  • Max. Switching Current: 3 A
  • Insulation Between Outputs Contacts: 1000 Vca
Serial Link:
  • Number: TMRT - 1; TMCU - 8
  • Interface: RS 485 for TMRT; RS 485/422 for TMCU
  • Transmission Speed: 1200 to 115200 bits/s
  • Protocols: HPTS, ASCII, Xon Xoff
  • Insulation Between Serial Links: 500 Vca (50 Hz, 1 min)
Deterministic WorldFIP Network:
  • Physical Layout: Monopair 120 ohms
  • Speed: 31.25 KBd
  • Insulation: 1000 Vca (transformer)
Norms:
  • Electrical and Mechanical Characteristics: Compliant with EN 50 155 and RIA12
  • Operating Temperature: -25°C to +70°C
See more

Catalog excerpts

TMRT - TMCU   Railways embedded watertight PLC-1

TMRT - TMCU Railways embedded watertight PLC TMRT Customized for OEM from LEROY standard PLC EN50155 embedded PLC for London underground (5000 products)

 Open the catalog to page 1
TMRT - TMCU   Railways embedded watertight PLC-2

MAIN CHARACTERISTICS TMRT Mechanical Dimension (without fixation) Weight Connectors Fixation Protection Toxic fumes By screw IP67 0 halogen (UL94-V0 norm) : no toxic fumes Power Supply Nominal voltage Maximum error at full scale Required power on BT (without I/O) First Protection -52 Vcc +25%,-40% 10 to 45 W Polarity Inversion and Over voltage Logic Inputs Number Nominal voltage Incoming Current, Nominal voltage Logic Outputs Number (not isolated between outputs contacts) Max. switching current Insulation between outputs contacts Serial link Number Interface Transmission speed Protocols (on basis)...

 Open the catalog to page 2

Archived catalogs

  1. BRIO

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.