1. Catalogs
  2. LEROY AUTOMATION
  3. RIOM 2nd generation

RIOM 2nd generation

RIOM 2nd generation

RIOM 2nd generation

Product catalog summary
Main Features
Mechanical Specifications:
  • Dimensions: 148 x 249 x 71.5 mm
  • Assembly: By screw
  • Weight: 2.5 Kg to 3.5 Kg depending on I/O configuration
  • Protection: IP30
  • Connectors: WorldFIP network (SubD9), Serial (SubD25 and DIN 41612 F48), Power supply, BT inputs/outputs (DIN 41612 F48)
  • Operating Temperature: -40°C to +85°C
Power Supply:
  • Nominal Voltage: 24Vcc or 72-110Vcc with a tolerance of -30% to +25%
  • Consumption: 10 to 30 W without I/O
  • First Protection: Polarity Inversion and Over voltage
Digital Inputs/Outputs:
  • 32 or 64 digital inputs with nominal voltage options of 24, 36, 48, 72, 96, or 110 Vcc and incoming current of 10 mA
  • 16 or 32 digital outputs with contact voltage of 16 to 160 Vcc, max switching power of 8A at 30 Vcc or 0.4A at 110 Vcc, and insulation between output contacts of 1000 Vca (50 Hz, 1 min)
Analog Inputs/Outputs:
  • 4 Analog Inputs with scales of ±10V, ±20mA, 4-20mA and resolution/precision of 1/4096 (12 bits) / 2%
  • 4 Analog Outputs with scales of 0-10V, 0-20mA, 4-20mA and resolution/precision of 1/4096 (12 bits) / 2%
Serial Links:
  • Number: 2 to 6
  • Interface: RS232 and RS485
  • Transmission Speed: 1200 to 115200 bits/s
  • Protocols: HPTS, ASCII, Xon Xoff
  • Insulation between Serial links: 500 Vca (50 Hz, 1 min)
WorldFIP Network:
  • Medium: Simple or redundant
  • Physical Layout: Monopair 120 ohms
  • Speed: 31.25 KBd or 1MHz
  • Insulation: 1000 Vca (transformer)
Optional Networks:
  • MVB and CAN via additional PC104 card
EMC Norms:
  • Electrical and Mechanical Characteristics: EN 50 155
  • Electromagnetic Compatibility: EN 50 121–3-2, EN 50 022
See more

Catalog excerpts

RIOM 2nd generation-1

Railway embedded compact PLC Customized for OEM from LEROY standard PLC EN50155 embedded Remote Input/Output Module for MF2000 PARIS underground

 Open the catalog to page 1
RIOM 2nd generation-2

Main features Mechanical Dimension Assembly Weight (regarding I/O configuration) Protection Connectors Operating Temperature HxWxD = 148 x 249 x 71.5 mm By screw 2.5 Kg to 3.5 Kg IP30 WorldFIP network : SubD9 Serial : SubD25 and DIN 41612 F48 Power supply, BT inputs / outputs : DIN 41612 F48 -40° C to + 85°C Power Supply Nominal Voltage Consumption (without I/O) First Protection 24Vcc or 72-110Vcc -30%,+25% 10 to 30 W Polarity Inversion and Over voltage 32 or 64 digital inputs Nominal voltage Incoming current, Nominal voltage 16 or 32 digital outputs Voltage on the contact Max. switching power...

 Open the catalog to page 2

Archived catalogs

  1. BRIO

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.