1. Catalogs
  2. LEROY AUTOMATION
  3. Railway Basic Remote Input Output device

Railway Basic Remote Input Output device

Railway Basic Remote Input Output device

Railway Basic Remote Input Output device

Product catalog summary
Overview
The BRIO module is a compliant device designed for integration into Train Control, Communication, and Management Systems. It supports both digital and analog I/O and can be mounted in a 6U rack or as a standalone unit. It communicates via Ethernet using TCP, UDP, CIP, and TRDP protocols.

Attributes and Benefits
  • Configurable without programming.
  • Wide power supply range (16.8V to 137.5V).
  • High-frequency digital inputs and continuous fritting current.
  • FPGA-based IO control with processing time under 100μs.
  • Low latency between Ethernet command and relay switching.

Communication
  • 1 Ethernet bus 100Mbits IEEE802.3.
  • IP address assignment via DHCP or external Key Identifier.
  • Supports UDP, TCP, Ethernet/IP CIP, and TRDP protocols.

Mounting Options
  • 6U x 6HP rack or remote standalone mounting.
  • Field IO signals connect via two DIN41612 F48 class 1 connectors.

Range and Specifications
  • Various configurations with different numbers of digital and analog inputs/outputs.
  • Relay outputs with specific load breaking capacities and endurance tests.
  • Static outputs with MOSFET technology and protection features.
  • Analog inputs and outputs with specific resolution and accuracy.

General Specifications
  • EN50155 compliant with full range power supply and protection features.
  • Digital inputs with adjustable filtering and monitoring capabilities.
  • Relay and static outputs with specific isolation and protection features.

Communication and Serial Links
  • Ethernet communication with IP address assignment options.
  • RS485 and RS232 serial links for local settings.

Compliance and Testing
  • EMI immunity tests according to various NF EN standards.
  • Mechanical and climatic tests for shock, vibration, and temperature resilience.

Note
Specifications are subject to change without notice.
See more

Catalog excerpts

Railway Basic Remote Input Output device-1

BRIO Railway Ethernet remote input/output device Product range : digital & analog I/O 6U Rack or remote stand alone mounting Ethernet link with TCP, UDP, CIP, TRDP protocols

 Open the catalog to page 1
Railway Basic Remote Input Output device-2

The Basic Remote Input Output (BRIO) module is an EN50155 / IEC60571 compliant module designed to be integrated into Train Control, Communication and Management Systems. Configurable device (no programming required) Full range power supply 16.8V to 137.5V Internal readback channels for each static output High frequency (up to 20KHz) voltage independent (24V to 110V) digital inputs Continuous digital input fritting current (no pulsed sampling) of 10mA FPGA-based IO control (filtering, serialisation, etc.) processing time less than 100μs Positioning by key identifier Latency between Ethernet command...

 Open the catalog to page 2
Railway Basic Remote Input Output device-3

EN50155 Full range power supply (16.8V to 137.5V) Power Supply • Monitoring of the power supply secondary stage • Protection against polarity reversal, under voltage and overvoltage • Power consumption < 20W Digital Inputs Full range voltage (24V to 110V) digital inputs • Software configurable logic levels (option) • Adjustable filtering settings • Continuous fritting current (no pulsed sampling) : 10mA ±10% • Monitoring of the digital input circuits (forcing test) • Protection against polarity reversal Power consumption per input at any nominal voltage and a continuous fritting current...

 Open the catalog to page 3
Railway Basic Remote Input Output device-4

Analog inputs Voltage (±10V) AND Current (±20mA) • Monitoring of the analog input circuits (ADC test) • Resolution : 1/4096 (11 bits + sign) • Accuracy : 2% of the full scale • Impedance : 10kft (voltage) or 113ft (current) • Protection against overvoltage :±15V (Voltage) , ±6V (current) Analog output Configurable voltage (0-10V) OR current (4-20mA) • Voltage or Current choice by wiring • Monitoring of the analog output voltage range (overflow test) • Resolution : 1/4096 (11 bits + sign) • Accuracy : 2% of the full scale • Impedance : <10ft (voltage) or >100kft (current) • Protection against...

 Open the catalog to page 4