1. Catalogs
  2. LEMO
  3. Cable special and fiber optic

Cable special and fiber optic

Cable special and fiber optic
1 / 53 PagesView full catalog

Cable special and fiber optic

Product catalog summary
Production and Quality Assurance
The document emphasizes the high standards of workmanship in producing special and fibre optic cables, certified to DIN ISO 9001:2008 standards. Key components include cable assembly and system technology, with computer-assisted final control and a dedicated fibre optic SMPTE department.
Product Range
A comprehensive list of cable types is provided, including coaxial, triaxial, audio, multiconductor, high voltage, hybrid, spiral, miniature, and fibre optic cables. Military tactical fibre optic cables and basestation cables, along with CAT 5 and CAT 7 cables, are also mentioned.
Order Information
Details include specifications for LEMO connector collet diameters and conductor colors according to DIN 47 100 (VDE 0812). Material abbreviations for conductor and insulation materials, such as copper, steel, and various polymers, are provided.
Coaxial Cables
Specifications for HF-coaxial cables according to MIL C17 standards are detailed, including electrical, mechanical, and general properties, with information on materials and dimensions.
Technical Specifications
Each cable type is listed with part number, impedance, capacitance, attenuation, operating voltage, temperature range, lead time, and suitable sizes, providing detailed technical data for selection.
Specifications
Detailed specifications for various cables, including DUAL RG 174 A/U, RG 174 POLYOLEFIN, RG 58 PU, triaxial, video, and audio cables, are provided with impedance, capacitance, attenuation, operating voltage, temperature range, and mechanical properties.
Cable Types and Properties
  • DUAL RG 174 A/U: Impedance of 50 ± 2 Ohm, capacitance of 101 pF/m, attenuation of 31.5 dB/100 m at 100 MHz, operating voltage of 1.5 KVeff, temperature range from -40°C to +70°C.
  • RG 174 POLYOLEFIN: Similar specifications with slight variations in attenuation and temperature.
  • RG 58 PU: Impedance of 50 ± 2 Ohm, capacitance of 101 pF/m, attenuation of 23 dB/100 m at 100 MHz, operating voltage of 1.90 KVeff, temperature range from -40°C to +80°C.
  • Triaxial Cables: Available in 50 Ω and 75 Ω versions for audio and video applications.
  • Video and Camera Cables: Designed to DIN 47383 / 96 IEC 75-4-4 standards, with impedance of 75 Ω.
  • Audio Cables (Twinax): Feature double spiral screens for flexibility and good crosstalk attenuation.
Material and Construction
Specific materials for inner conductor, insulation, screen, and outer sheath are detailed, including copper, polyethylene, polyvinyl chloride, and polytetrafluoroethylene.
Mechanical Properties
Mechanical properties include flexibility, insulation resistance, and temperature ranges for flexible and static conditions.
Recommendations and Standards
Cables meet industry standards such as AES/EBU for audio cables and DIN/IEC for video cables, with recommendations for use and suitable applications.
Specifications
Specifications for audio, miniature control, and microphone cables are outlined, including wire cross-section, operating voltage, insulation resistance, and temperature ranges.
Procedures and Standards
Standards such as DIN 47 100 and VDE 100/Part 430 + 523 are referenced for wire colors and current-carrying capacity.
Recommendations
Color options and bending radius recommendations are provided.
Key Data from Tables
Wire structure configurations, insulation and sheath materials, and critical information on operating and storage temperatures, voltage, and resistance are summarized.
Technical Document Summary
1. Specifications: Detailed specifications for multiconductor, silicone, and computer cables, including wire cross-section, operating voltage, test voltage, conductor resistance, insulation resistance, and temperature ranges.
2. Procedures and Standards: Cables are approved according to UL-Style and VDE standards, suitable for control, medical, and chemical techniques.
3. Recommendations: Silicone cables are recommended for high-temperature environments, and pair-twisted shielded cables for digital and impulse techniques.
4. Key Data from Tables: Detailed information on structure, insulation, and outer sheath materials, conductor resistance, operating voltage, and test voltage.
5. Critical Information: Important parameters include maximum operating voltage, test voltage, and temperature ranges.
Overview: Detailed specifications and characteristics of various cables, including computer, coaxial, and high voltage cables, with information on wire cross-sections, operating and testing voltages, resistance, temperature ranges, and other physical properties.
Specifications:
  • Wire Cross Section: Ranges from 0.14 mm² to 0.56 mm².
  • Operating Voltage: Typically 300 V for control cables, 100 V for coaxial cables, up to 600 V for high voltage cables.
  • Test Voltage: Ranges from 1500 V to 2000 V.
  • Conductor Resistance: Varies by cable type.
  • Insulation Resistance: Generally 153 MOhm x km at 20 °C.
  • Temperature Range: Operating temperatures range from -40 °C to +200 °C.
  • Bending Radius: Typically 5x the outer diameter for fixed installations.
Materials and Construction:
  • Insulation: Commonly PVC, PTFE, or FPM.
  • Screening: Often made of copper or copper alloy.
  • Outer Sheath: Typically black PVC.
Applications: Suitable for control systems, high voltage connections, and specific temperature and resistance environments.
Compliance: Qualified according to UL-Style and VDE standards.
Technical Document Summary
1. Specifications: Detailed specifications for special-combination, hybrid, spiral, miniature, and fibre optic cables.
2. Procedures: Construction and components of each cable type, including order quantities and available lengths.
3. Standards and Norms: Compliance with standards such as MIL-W-16878 Type B and UL-Style No. 2560.
4. Recommendations: Use of hybrid cables for specific applications, ensuring compatibility between connectors and cables.
5. Key Data from Tables: Insulation and resistance values, voltage ratings, materials, dimensions, and order quantities.
6. Critical Information: Minimum order quantities, stock availability, and best practices for compatibility.
Specifications: Specifications for fibre optic cables, including CU-conductors, screening options, and outer diameter.
Assembly Procedures: Expertise and tools required for assembling fibre optic cables, with details on connectors.
Breakout Cables: Designed for indoor and outdoor use, with construction details and applications.
Hybrid Cables: Conform to SMPTE 311-2009 standards, with variants for high-flex and flame-retardant options.
Military Tactical Cables: Designed for military and commercial use, with specifications for fibre core and sheath dimensions.
Key Data from Tables: Detailed specifications for various cable types, including part numbers and environmental conditions.
Specifications: Specifications for military tactical field cables, designed for adverse environments.
Procedures and Standards: Compliance with EN 50173 and ISO/IEC 11801 standards.
Recommendations: Special cables for mobile network base stations, with strand and wire technology recommendations.
Cable Assembly: Details on cable assembly, including LEMO connectors and compliance with EU Directive 2002/95/EC (RoHS).
Contact Information: LEMO subsidiaries in various countries with contact details.
See more

Catalog excerpts

Cable special and fiber optic-1

SPECIAL CABLE AND FIBRE OPTIC CABLE SPEZIALKABEL UND LWL-KABEL

 Open the catalog to page 1
Cable special and fiber optic-2

Unsere Produktion The high standard of our workmanship ensures a constant high quality of our products. Der hohe Leistungsstandard unserer Mitarbeiter sichert eine konstante Qualität unserer Produkte. Cable assembling and system technology Konfektionieren von Steckverbinungen und Systemtechnologie Final control by computer Voll computergesteuerte Endkontrolle Fibre optic SMPTE department A view in our big cable warehouse. The appropriate cable for almost any LEMO connector can be supplied ex warehouse. Ein Blick in unser großes Kabellager. Wir liefern für fast jede LEMO-Steckverbindung das passende...

 Open the catalog to page 2
Cable special and fiber optic-3

Order information Coaxial cable Triaxial cable Triaxial cable I video cable Audio cable Multiconductor cable Multiconductor cable PTFE Multiconductor cable Multiconductor Silicone I PUR-cable Computer cable Special cable in FPM I PEEK High voltage cable Special-combinations cable Hybrid cable Spiral cable Miniature cable Fibre optic cable Military Tactical fibre optic cable Basestation-cable CAT 5 I CAT 7 cable Cable assembly Catalog summary Inhaltsverzeichnis Page I Seite 4 - 5 Bestellinformationen 18 Mehradrige PTFE Kabel 23 Mehradrige Silikon I PUR-Kabel

 Open the catalog to page 3
Cable special and fiber optic-4

4 Order information Bestellinformationen Collet diameter of the LEMO-connectors Spannzangendurchmesser der LEMO-Stecker Material abbreviations CuSn CuAg Cu - blk. CuSt CuStAg CrNi CuCu AgAg AgCu SnSn Fe vzkt CuM PVCI PVCII PE PU PTFE FEP PTFE + GSi HL PETP StSn FPM CuSn CuAg Cu - blk. CuSt CuStAg CrNi CuCu AgAg AgCu SnSn Fe vzkt CuM PVCI PVCII PE PU PTFE FEP PTFE + GSi HL PETP StSn FPM Copper wire tinned Copper wire silver Copper wire bare Steel wire, copper-plated Steel wire, copper-plated, silver Chrome-Nickel-wire double-screened double-screened double-screened double-screened armoured,...

 Open the catalog to page 4
Cable special and fiber optic-5

List of abbreviations in stock on request meter blk. tr

 Open the catalog to page 5
Cable special and fiber optic-6

6 Coaxial cables Koaxialkabel Electrical and general properties *HF-Koaxialkabel nach MIL C17 (50, 75, 93 Q) Elektrische und allgemeine Daten Mechanical properties Mechanische Daten 1) Please request for the active available lengths 1) Bitte fragen Sie nach den aktuell verfugbaren Langen

 Open the catalog to page 6
Cable special and fiber optic-7

Koaxialkabel HF-coaxial cable - Special version DUAL Cable RG 174 A/U Electrical and general properties HF-Koaxialkabel in Sonderausfuhrung Kabel Dual RG 174 A/U Elektrische und allgemeine Daten Mechanical properties Mechanische Daten Polyolefin cable RG 174 Electrical and general properties Kabel Polyolefin RG 174 Elektrische und allgemeine Daten Mechanical properties Mechanische Daten Cable RG 58 B/U (PUR) Electrical and general properties Kabel RG 58 B/U (PUR) Elektrische und allgemeine Daten Mechanical properties Mechanische Daten Inner conductor I Innenleiter Structure Mat. Aufbau |0...

 Open the catalog to page 7
Cable special and fiber optic-8

Triaxialkabel Triaxial cable 50 Q (Audio cable) Triaxial cable 75 Q (Video cable) Electrical and general properties Triaxialkabel 50 Q (Audiokabel) Triaxialkabel 75 Q (Videokabel) Elektrische und allgemeine Daten 1) Other colours up 100 m on request 1) Andere Farben ab 100 m auf Anfrage

 Open the catalog to page 8
Cable special and fiber optic-9

Low noise triaxial cable Electrical and general properties Rauscharme Triaxialkabel Elektrische und allgemeine Daten Mechanical properties Mechanische Daten

 Open the catalog to page 9
Cable special and fiber optic-10

Audiokabel Twinax cable (double wire screened) Very flexible with good cross talk attenuation The mentioned colours are available in stocks. Other colours on request. Wire colours according to DIN 47 100 Twinaxkabel (zweiadrig, geschirmt) Hochflexibel mit guter Ubersprechdampfung In den aufgefuhrten Farben ab Lager lieferbar. Andere Farben auf Anfrage. Aderfarbfolge nach DIN 47 100 ultra flexible I * ultraflexibel Twinax cable with double spiral screen Very flexible Highly stabilized impedance AES/EBU specified Wire colour red, white Temperature range (flexible) -5°C to +50°C Temperature range...

 Open the catalog to page 10
Cable special and fiber optic-11

Audiokabel 11 Sound modulation cable with a crosstalk attenuation of 125 dB 11 Andere Farben ab 100 m auf Anfrage Other colours up 100 m on request

 Open the catalog to page 11
Cable special and fiber optic-12

12 Multiconductor cables Mehradrige Kabel Very flexible cables, several wires, unscreened Wire cross section 0,04 mm2 (max. operating voltage 200 V) Mehradrige ungeschirmte, hochflexible Leitungen Aderquerschnitt 0,04 mm2 (max. Betriebsspannung 200 V) Colour Wire colours Operating voltage Test voltage Conductor resistance Insulation resistance Capacitance approx. Operating temperature Stockage temperature Bending radius grey a ccording to RAL 7032 according to DIN 47 100 250 V 800 V max. 600 Ohm/km 20 MOhm x km Wire/wire 60 pF/m -10 °C to +80 °C -30 °C to +80 °C 10 x 0 Farbe Aderfarbfolge Betriebsspannung Prufspannung Leiterwiderstand Isolationswiderstand...

 Open the catalog to page 12
Cable special and fiber optic-13

Multiconductor cables Mehradrige Kabel _13 Very flexible cables, several wires, screened, couple twisted, Wire cross section 0,08 mm2 / 0,09 mm2 (max. operating voltage 250 V) screening with filling material strand Mehradrige geschirmte Leitungen, leicht paarverseilt, hochflexibel Aderquerschnitt 0,08 mm2 / 0,09 mm2 (max. Betriebsspannung 250 V) Abschirmgeflecht mit Beilauflitze Colour Wire colours Operating voltage Test voltage Conductor resistance Capacitance approx. Operating temperature Stockage temperature Bending radius grey according to RAL 7032 according to DIN 47 100 250 V Wire/wire...

 Open the catalog to page 13
Cable special and fiber optic-14

14 Multiconductor cables Mehradrige Kabel Wire cross section Operating voltage Test voltage Conductor resistance Insulation resistance Temperature range Wire colours Outer sheath Sheath colour 0,08 mm2 (10 x 0,10 mm) max. 250 V ~ 600 V ~ 236 Ohm/km at 20 °C > 1.000 MOhm x km -20 °C to +80 °C acc. to DIN 47100 PVC gray, RAL 7001 Einzeln abgeschirmte kapazitatsarme Mikrofonleitung Aderquerschnitt Betriebsspannung Prufspannung Leiterwiderstand Isolationswiderstand Temperaturbereich Aderfarbfolge AuBenmantel Mantelfarbe 0,08 mm2 (10 x 0,10 mm) max. 250 V ~ 600 V ~ 236 Ohm/km bei 20 °C > 1.000 MOhm...

 Open the catalog to page 14
Cable special and fiber optic-15

Multiconductor cables Mehradrige Kabel _15Multiconductor unshielded and shielded cable, Wire cross section 0,11 mm2/0,14 mm2 (max. voltage rating 250 V)Mehradrige ungeschirmte und geschirmte Leitungen, Aderquerschnitt 0,11 mm2/0,14 mm2 (max. Betriebsspannung 250 V) Wire cross section Operating voltage Test voltage Conductor resistance Min. insulation resistance Capacitance approx. Operating temperature Stockage temperature Bending radius Wire colours Chargeable to a maximum of 0,11/0,14 mm2 max. 250 V 2000 V max. 148 Ohm/km 200 MOhm x km at 20 °C 120 pF/m from -15 °C to +70 °C from -30 °C to...

 Open the catalog to page 15

All LEMO catalogs and technical brochures

  1. D Series

    36  Pages

  2. REDEL P

    76  Pages

  3. 0A Series

    2  Pages

  4. REDEL SP

    20  Pages

  5. 2G/2C SERIES

    20  Pages

  6. W SERIES

    24  Pages

  7. R SERIES

    32  Pages

  8. F Series

    48  Pages

  9. T SERIES

    32  Pages

  10. 3K.93C.Y Series

    20  Pages

  11. V SERIES

    24  Pages

  12. REDEL MP Series

    40  Pages

  13. C1 SeRieS

    4  Pages

  14. Serbal 3G

    2  Pages

  15. HD Z-LINK

    2  Pages

  16. Elbow plugs

    4  Pages

  17. Coaxial 3GHz

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.