MICROSYSTEMS A breakthrough in sample preparation yield, simplicity and speed in high end cryo coating LEICA EM ACE900 Freeze Fracture System
Open the catalog to page 1LEICA EM ACE900 FULLY AUTOMATED FREEZE FRACTURE SYSTEM The new Leica freeze fracture instrument has a redesigned cooling concept, microtome, shielding, e-beams load locks, and offers a connection to the EM VCT500 cryo transfer system for protection of the samples during the complete cryo SEM working process. Embedded in a modern userinterface there are no more barriers to operate. Leica Mikrosysteme GmbH, Vienna, Austria
Open the catalog to page 2WHY FREEZE FRACTURE AND FREEZE ETCHING? Freeze fracture describes the technique of breaking a frozen specimen to reveal internal structures. Freeze etching is the sublimation of surface ice under vacuum to reveal details of the fractured face that were originally hidden. A metal / carbon mix enables the sample to be imaged in an SEM (block-face) or TEM (replica). It is used to investigate for instance cell organelles, membranes, layers and emulsions. The technique is traditionally used for biological applications but started to develop significantly in physics and material science. Freeze fracture...
Open the catalog to page 4The Leica EM ACE900 is a high-end sample preparation system for freeze fracturing, freeze etching and high resolution cryo coating. This instrument is easy and intuitive to use. To achieve highest sample protection sample transfer, large cryo-shields, and the sample shutter are optimized. Users obtain best results because the instrument stays always in high vacuum. This is provided by a load lock system, a knife transfer, and gate valves for each e-beam source. The perfect combination of automation and optional manual operation makes the preparation process highly reproducible and flexible. Versatility,...
Open the catalog to page 5APPLICATION IMAGES Giardia lamblia Drosophila larva
Open the catalog to page 6Sample preparation and imaging by Andres Käch, Center for Microscopy and Image Analysis, 6.7 University of Zurich, Switzerland Human platelets (first) Stigeoclonium tenue (second and third) Euglena gracilis Klebs
Open the catalog to page 7DISCOVER LEICA EM ACE900 UNIQUE FEATURES Accurate fracturing with a 3-axis movable cryo-knife and the possibility to exchange it via load lock High protection from water contamination due to large, closed cryo shield and automated cryo cooled sample shutter High vacuum is crucial to keep the sample contamination free and achieve fine grained coating for highest resolution and stable replicas E-beam coating of different materials gives the finest possible structures of coated materials Bench top instrument saves space and guarantees a comfortable operation Programmable and fully automated operation...
Open the catalog to page 8PERFECT CONDITIONS >> Vacuum is kept at all times >> Load locks for sample, microtome, and e-beams INTEGRATED THICKNESS MEASUREMENT >> Stabilize coating before starting the process >> Controlled and accurate layer thickness REPRODUCIBLE PROCESSES >> Programmable operation >> Accurate monitoring and controlling of the sample temperature during the complete freeze etching process PRECISE SAMPLE MANIPULATION >> Fresh blade for each cut avoids contamination >> Exchangeable and 3-axis movable knife >> Accurate feed 0.2 micrometer steps FOCUS ON YOUR SAMPLE >> Easy operation without distraction for...
Open the catalog to page 9CONNECTIVITY Dock the vacuum cryo transfer unit Leica EM VCT500 to Leica EM ACE900 An EM VCT500 dock is directly attached to the EM ACE900. Via the EM VCT500 shuttle specimens are transferred in and out of the sample preparation instrument to be perfectly preserved for the final examination in a cryo SEM. In this way the fractured block face of a frozen sample is imaged at highest resolution. It takes only a short time to take a native sample through the complete workflow to analysis. PREPARATION WORKFLOW Leica EM VCM loading station with Leica EM ICE High Pressure Freezer Leica EM VCT500 Cryo...
Open the catalog to page 10ENVIRONMENTAL IMPACT >> LN2 consumption during cooling down has been reduced by approx. 85% in comparison to previous instruments. >> LN2 consumption for cryo work per hour has been reduced by approx. 60% in comparison to previous instruments. >> Time for cooling down to operation has been reduced by approx. 35% in comparison to previous instruments. >> The instrument is smaller, that means: less environmental impact of packaging, shipping and less cost for the customer. >> The instrument comes from a development and production site in which the environmental management system DIN EN ISO 14001...
Open the catalog to page 11qualityaustria SYSTEM CERTIFIED ISO 9001:2008 No.00805/0IS014001:2004 No.02783/0 Leica Mikrosysteme GmbH | Vienna, Austria T +43 1 48899-0 | F +43 1 48899-350 www.leica-microsystems.com Leica EM ACE900 Brochure • English • 06/2017 • Order no. 167240002 • Copyright © by Leica Mikrosysteme GmbH, Vienna, Austria, 2017. Subject to modifications. LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH.
Open the catalog to page 122 Pages
12 Pages
2 Pages
16 Pages
12 Pages
4 Pages
16 Pages
20 Pages
20 Pages
20 Pages
20 Pages
20 Pages
20 Pages
8 Pages
20 Pages
20 Pages
20 Pages
20 Pages
8 Pages
20 Pages
20 Pages
4 Pages
12 Pages
4 Pages
8 Pages
4 Pages
2 Pages
8 Pages
20 Pages
16 Pages
16 Pages
8 Pages
8 Pages
12 Pages
4 Pages
20 Pages
24 Pages
16 Pages
16 Pages
4 Pages
4 Pages
16 Pages
8 Pages
4 Pages
16 Pages
12 Pages
4 Pages
4 Pages
4 Pages
12 Pages
4 Pages
2 Pages
12 Pages
8 Pages
8 Pages
12 Pages
16 Pages
2 Pages
20 Pages
2 Pages
6 Pages
6 Pages
4 Pages
4 Pages
2 Pages
4 Pages
16 Pages
12 Pages
2 Pages
2 Pages
12 Pages
20 Pages
20 Pages
16 Pages
12 Pages
12 Pages
8 Pages
12 Pages
20 Pages
16 Pages
16 Pages
16 Pages
16 Pages
16 Pages
6 Pages
8 Pages
4 Pages
16 Pages
16 Pages
16 Pages
8 Pages
8 Pages
12 Pages
12 Pages
8 Pages
8 Pages
16 Pages
10 Pages
12 Pages
12 Pages
16 Pages
12 Pages
20 Pages
12 Pages
20 Pages
24 Pages
24 Pages
16 Pages
7 Pages
12 Pages
12 Pages
12 Pages
12 Pages
16 Pages