Catalog excerpts
FOR MORE INFORMATION CONTACT: 6799S-NP/11-10/20M/HESS PRINTED IN U.S.A. Specifications and prices subject to change without notice. © leeson electric, 2010
Open the catalog to page 1ABOUT THIS CATALOG The Motors listed in the EPACT Supplement Catalog are motors that have been affected by the EISA Legislation. EISA is an acronym for Motors that are considered “Finished Goods” or are shipped Energy Independence from the factory before December 19, 2010 can be sold after & Securities Act. On December 19, 2010, motor manufacturers December 19, 2010 because they were built before the deadline. EISA applies to both NEMA frame motors and the equivalent IEC frame motor. may not build motors that have a lower DISTRICT SALES OFFICES AND WAREHOUSES LEESON District Sales Offices &...
Open the catalog to page 2TABLE OF CONTENTS THREE PHASE MOTORS Automatic Overload Motors . . . . . . . . . . . . . . . . . . . Page 5 IEC Metric Motors . . . . . . . . . . . . . . . . . . . . . . . Page 19-22 Automotive Duty Motors JM & JP Pump Motors Foot Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 C-Face With Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39-40 JM Pump Motors, Washguard All-Stainless . . . . . . . . . . 11 JM Pump, Drip-Proof . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 JP Pump, Drip-Proof . . . . . . . . . . . . . . . . . . . . ....
Open the catalog to page 3OTHER GENERAL PURPOSE MOTORS RIGID BASE • THREE PHASE F2 MOUNT MOTORS General purpose, three-phase motors with NEMA F2 conduit box location. DRIP-PROOF TEFC HP RPM 60 NEMA Catalog Disc. Hz Frame Number Sym. App. Wgt. (lbs.) Voltage F.L. Amps 230V % F.L. Eff. “C” Dim. (Inches) NEMA Catalog Disc. Frame Number Sym. 3 1760 182T G131240 B 63 208-230/460 8.4 5 1760 184T G131239 B 76 208-230/460 13.2 86.5 11.69 182T G131237 B 74 208-230/460 8.2 87.5 13.96 87.5 13.69 184T G131236 B 86 71⁄2 1760 213T G140609 B 96 208-230/460 20.0 88.5 208-230/460 13.0 87.5 14.96 15.26 213T G140604 B 119 208-230/460...
Open the catalog to page 7EXPLOSION-PROOF MOTORS THREE PHASE Rigid Base division i, division ii, Class I, Groups C & D — Class II, Groups F & G • W/CONDUIT BOX HP RPM 60 NEMA Catalog Disc. Hz Frame Number Sym. App. Wgt. (lbs.) Voltage Over- load Prot. F.L. Amps 230V % “C” F.L. Dim. Eff. (Inches) 11⁄2 3450 143T G120489 B 46 208-230/460 1725 145T G120490 B 56 208-230/460 Auto. 4.0 82.5 14.41 Auto. 4.4 84.0 14.41 2 3450 145T G120491 B 51 208-230/460 Auto. 5.2 84.0 15.41 1725 145T G120391 B 56 208-230/460 Auto. 5.6 84.0 15.41 3 3450 145T G120387 B 51 208-230/460 Auto. 7.4 85.5 15.91 C Face Less Base division i, division...
Open the catalog to page 14EXPLOSION-PROOF MOTORS THREE PHASE • C FACE C Face WITH Base division i, division ii, Class I, Groups C & D — Class II, Groups F & G • W/CONDUIT BOX HP RPM 60 NEMA Catalog Disc. Hz Frame Number Sym. App. Wgt. (lbs.) Voltage Over- load Prot. F.L. Amps 230V % “C” F.L. Dim. Eff. (Inches) 1 1725 143TC G121541v B 44 208-230/460 T-Stat 3.0 82.5 14.50 11⁄2 1725 145TC G121542v B 54 208-230/460 T-Stat 4.4 84.0 16.00 2 1740 145TC G121182 B 58 208-230/460 Auto. 5.6 84.0 15.02 B 65 208-230/460 T-Stat 5.6 84.0 16.50 v 1725 145TC G121543v These motors are inverter-rated and suitable for use with an...
Open the catalog to page 15ff???«??ft JM PUMP MOTORS «HS™"BSSK THREE PHASE TEFC • RIGID BASE WASHGUARD • TEFC • JM PUMP SHADED FRAME INDICATES CAST IRON CONSTRUCTION All three phase motors, 1 HP and above, are inverter rated. All motors are subject to availability.
Open the catalog to page 18TERMS AND CONDITIONS TERMS AND CONDITIONS OF SALES QUOTATIONS ARE MADE AND ORDERS ARE ACCEPTED BY SELLER ONLY TO THESE TERMS AND CONDITIONS. THE SELLER FOR THESE TERMS AND CONDITIONS APPLY TO BOTH LEESON ELECTRIC AND LINCOLN MOTORS PRODUCTS: 1. AGREEMENT AND MODIFICATION OF SALES TERMS. determined by Seller. (c) In the event spoilage/damage occurs on orders where Buyer The agreement between Seller and Buyer (“Sales Contract”) is with respect to the sale furnishes any material, Seller shall not be liable for replacement of or damage to such of goods described on the other side hereof (the...
Open the catalog to page 51TERMS AND CONDITIONS (including reasonable overhead) which the Seller would make from performance (h) Products not manufactured and work not performed by Seller are warranted only to together with incidental damages and reasonable costs. the extent and in the manner that the same are warranted to Seller by Seller’s vendors, 12. WARRANTIES, LIMITATIONS OF LIABILITY AND DISCLAIMER. and then only to the extent that Seller is reasonably able to enforce such warranty. (a) Seller warrants to the Buyer that its motors, gear reducers, gearmotors, gear- In enforcing such warranty, it is understood...
Open the catalog to page 52TERMS AND CONDITIONS reasonable control either of Seller or of suppliers of Seller. If any such contingency Wisconsin and hereby consent to the personal jurisdiction of such court in any such occurs, Seller may allocate Goods and deliveries among Seller’s customers. action over the parties hereto. The rights and obligations of Seller and Buyer shall not 16. ASSIGNMENT AND DELEGATION. be governed by the provisions of the United Nations Convention on Contracts for the No right or interest in the Sales Contract shall be assigned by Buyer without Seller’s International Sale of Goods. prior...
Open the catalog to page 53MOTOR WARNINGS AND CAUTIONS IMPORTANT INFORMATION PLEASE READ CAREFULLY This catalog is not intended to provide operational instructions. Appropriate LEESON Electric instructions provided with the motor and precautions attached to the motor should be read carefully prior to installation, operation and/or maintenance of the equipment. Injury to personnel or motor failure may be caused by improper installation, maintenance or operation. The following and information is supplied to you for your protection and to provide you with many years of trouble free and safe operation of your LEESON...
Open the catalog to page 54ABOUT THIS CATALOG The Motors listed in the EPACT Supplement Catalog are motors that have been affected by the EISA Legislation. EISA is an acronym for Motors that are considered “Finished Goods” or are shipped Energy Independence from the factory before December 19, 2010 can be sold after & Securities Act. On December 19, 2010, motor manufacturers December 19, 2010 because they were built before the deadline. EISA applies to both NEMA frame motors and the equivalent IEC frame motor. may not build motors that have a lower DISTRICT SALES OFFICES AND WAREHOUSES LEESON District Sales Offices &...
Open the catalog to page 55All LEESON Electric catalogs and technical brochures
-
Tobacco Barn Motors
1 Pages
-
Farm Ag Motors Bulletin 1040
12 Pages
-
IEC Brochure Bulletin 1855
8 Pages
-
Large Motors Bulletin 1304
6 Pages
-
Pulleys Catalog 1060
84 Pages
-
Bulletin 1400
8 Pages
-
Bulletin 1600IEC
36 Pages
-
Bulletin 1700
5 Pages
-
Energy Efficiency Brochure
6 Pages
-
Bulletin 1830
8 Pages
-
Fire Pump Motors
9 Pages
-
Bulletin 7052
8 Pages
-
VVVF Elevator Hoist Motors
1 Pages
-
MOTORS FOR AGRICULTURE
24 Pages
-
Bulletin 1055
8 Pages
-
Product Catalog 1050
534 Pages
-
parts Catalog
61 Pages
-
Basic Training
95 Pages