Installation
Prepare the mast head for mechanical installation using the provided template for bracket screwing. Align the bracket so the CV7-V sensor faces the bow while the mast is aligned to the North. Fine alignment is achieved through software calibration. Ensure the cable is routed to avoid electromagnetic interference.

DVC Characteristics
The ultrasonic wind sensor includes an anemometer and wind vane, providing wind speed and angle as analog signals. Key specifications include:
  • Output type: Anemometer (open-drain), Wind vane (digital potentiometer)
  • Output rate: Every 533 ms
  • Power supply: 2.7 V to 35 V
  • Cable: 6 conductors, 26 AWG, RJ-11 connector, 5 m length
  • Dimensions: Ø 65 mm, height 47 mm
  • Weight: 110 g
  • Electrical consumption varies with voltage

Interconnections
Details on RJ11 connector wiring and power supply:
  • Anemometer (WS): Yellow wire
  • Power supply (VREF): Black wire
  • Wind angle (WP): Red wire
  • Ground (GND): Green wire
  • Power supply: Brown wire
  • Ground (GND): Blue wire
The anemometer outputs a symmetrical square signal with frequency proportional to wind speed. The wind vane uses a digital potentiometer to convert wind angle.

Technical Specifications
Specifications include:
  • Wind speed range: 0.25-40 m/s (0.5 – 80 knots)
  • Wind speed resolution: 0.1 m/s (0.1 knots)
  • Wind direction range: 0-359°
  • Power requirement: 2.7 V to 35 V DC
  • Operational temperature: -15°C to +55°C
  • Environment: Sensor IP67

Dimensions
Overall dimensions are provided, including sensor and arm measurements.

Warranty
The CV7-V is warranted for 2 years against manufacturing defects. Claims require proof of purchase and must be made in writing to LCJ Capteurs. Faulty products should be sent to their address in Vertou, France.

For more information, visit the LCJ Capteurs website.
See more

Catalog excerpts

Instructions for use SONIC-ANEMO-DVC-1

Ultrasonic Wind Sensor LCJ CAPTEURS - ZA le Chêne Ferré 44120 VERTOU – France - Tel 33(0)2 40 05 08 55 [email protected] Reg. 42493307500022 / RCS Nantes – VAT : FR17424933075 Page 1 o

 Open the catalog to page 1
Instructions for use SONIC-ANEMO-DVC-2

1. Installation Prepare the mast head for the mechanical installation. Use the template for the bracket’s screwing. Align the bracket in order to have the CV7-V sensor heading to the bow while the mast is aligned to the North. The sensor’s fine alignment will be obtained with the software calibration application. Run the cable down to the display’s interface, avoiding locations where other cables or equipment may produce electromagnetic interferences. Sensor view from below Bracket mounting template Note : for mounting on vertical surface, the brackets RA106BRACKET and RA106BRACKINOX from Glomex®...

 Open the catalog to page 2
Instructions for use SONIC-ANEMO-DVC-3

2. DVC CHARACTERISTICS Ultrasonic wind sensor has got an anemometer and wind vane. Wind speed and angle are provided in the form of analog signals. The characteristics of the sensor have been verified in wind tunnel. Synoptic : Generalities : Output type : Anemometer : open-drain Wind vane : digital potentiometer Output rate : every 533 ms Power supply : 2,7 V to 35 V. Cable : 6 conductors, 26 AWG, RJ-11 connector, length 5 m. Dimensions : 0 65 mm ; height : 47 mm. Weight : 110 gr Maximum of consumptions. LCJ CAPTEURS - ZA le Chene Ferre 44120 VERTOU - France - Tel 33(0)2 40 05 08 55 [email protected] Reg....

 Open the catalog to page 3
Instructions for use SONIC-ANEMO-DVC-4

3. Interconnections On RJ11 connector : Anemometer : (WS) yellow wire Power supply (VREF) potentiometer : black wire Wind angle (WP) : red wire Ground (GND) : green wire Power supply wires: Power supply : brown wire Ground (GND) : blue wire Anemometer : Output signal WS is an open-drain. Maximum current : 170 mA. Maximum voltage : 100 V The signal who is generated is a symmetrical square signal. The frequency is proportional to the wind speed. For a signal of F frenquency, we have got a wind speed : Vmph= 2,25 F in miles/hour. Vkt= 1,95 F in knots. Vkm/h= 3,62 F in Km/h. Vm/s= 1,006 F in m/s....

 Open the catalog to page 4
Instructions for use SONIC-ANEMO-DVC-5

4. SONIC-ANEMO-DVC Technical Specifications: Wind speed range Wind speed resolution Wind speed sensitivity Wind direction range Wind direction resolution Wind direction sensitivity Power requirement Power consumption Dimensions / Sensor Boot up delay Cable Arm Cable weight Weight / Sensor + arm and base Weight / Sensor Operational temperature Environement CE Mark 0.25-40 m/s (0.5 – 80 knots) 0.1 m/s (0.1 knots) 0.13 m/s (0.25 knots) Independent of weather conditions 0-359 ° 1° +/- 1 ° 2.7 V to 35 V DC 2.6 mA @ 12V Cylinder Ø 64 mm - height 61 mm 4 seconds 25 m standard delivery 4x0.22 mm². Ø4...

 Open the catalog to page 5
Instructions for use SONIC-ANEMO-DVC-6

LCJ CAPTEURS - ZA le Chêne Ferré 44120 VERTOU – France - Tel 33(0)2 40 05 08 55 [email protected] Reg. 42493307500022 / RCS Nantes – VAT : FR17424933075 Page 6

 Open the catalog to page 6
Instructions for use SONIC-ANEMO-DVC-7

6. Warranty Your CV7-V is warranted against manufacturing defects in materials and workmanship for a period of 2 years from the date of purchase. LCJ Capteurs will at its discretion, repair or replace faulty product free of charge excluding the cost of shipping. Proof of purchase shall be required in order for a warranty claim. All claims shall be made in writing to LCJ Capteurs and once it is accepted by LCJ Capteurs, the faulty product must be sent to LCJ Capteurs address in Vertou, France. For further information, please visit www.lcjcapteurs.com where video presentations are available. EN...

 Open the catalog to page 7
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.