Installation
Prepare the mast head for mechanical installation using the provided template for the bracket's screwing. Align the bracket so the CV7-OEM sensor faces the bow while the mast aligns with the boat's midline. Fine alignment is achieved through software calibration. Ensure the cable is routed to avoid electromagnetic interference.

Wind Sensor Alignment and Configuration
The CV7-OEM is pre-configured with NMEA0183, a 2-second filtering, wind force in knots, temperature in Celsius, and a wind angle adjustment of 0°. Configuration changes can be made using downloadable software from the LCJ Capteurs website. Power supply connections require 12V (3 to 30 VDC) with specific wiring for NMEA 0183 standard input.

Technical Specifications
The sensor measures wind speeds from 0.25 to 40 m/s with a resolution of 0.1 m/s and sensitivity of 0.13 m/s. It operates independently of weather conditions, with a wind direction range of 0-359° and a resolution of 1°. Power requirements are 8V to 33V DC with a consumption of 9 mA. The sensor is IP67 rated and operates between -15°C to +55°C.

NMEA0183 Protocol
The protocol operates at a baud rate of 4800 with 8 data bits, no parity, and 1 stop bit. Data is transmitted every 512 milliseconds with variable length fields. Sentences start with '$' and end with CR,LF. Voltage outputs are 0 or 5V.

Warranty
The CV7-OEM comes with a 2-year warranty against manufacturing defects. LCJ Capteurs will repair or replace faulty products at their discretion, excluding shipping costs. Proof of purchase is required for warranty claims, which must be made in writing.

For more information, visit the LCJ Capteurs website where video presentations are available. Remember to dispose of non-working electronic equipment at appropriate waste disposal centers.
See more

Catalog excerpts

Instructions for use CV7-OEM-1

Ultrasonic Wind Sensor LCJ CAPTEURS - ZA le Chêne Ferré 44120 VERTOU – France - Tel 33(0)2 40 05 08 55 [email protected] Reg. 42493307500022 / RCS Nantes – VAT : FR17424933075 Page 1 o

 Open the catalog to page 1
Instructions for use CV7-OEM-2

1. Installation Prepare the mast head for the mechanical installation. Use the template for the bracket’s screwing. Align the bracket in order to have the CV7-OEM sensor heading to the bow while the mast is aligned to the boat’s midline. The sensor’s fine alignment will be obtained with the software calibration application. Run the cable down to the display’s interface, avoiding locations where other cables or equipment may produce electromagnetic interferences. Sensor view from below LCJ CAPTEURS - ZA le Chêne Ferré 44120 VERTOU – France - Tel 33(0)2 40 05 08 55 [email protected] Reg....

 Open the catalog to page 2
Instructions for use CV7-OEM-3

2. Wind sensor alignment and configuration CV7-OEM is delivered with the following configuration : NMEA0183® Filtering: 2 s Forces of wind unity : Nds Temperature unity: °C Adjustment of the angle of the wind: 0° To choose other parameters, use the downloadable software on this website: www.lcjcapteurs.com. « Configuration_CV7_C ». Realise the following connexions: SubD 9 points Red cable Blue cable Yellow cable Green cable For NMEA 0183 standard input ( RS422) Power supply connections 12V (3 à 30 VDC). Wire Blue - / Wire Red + Red Blue Yellow Green + Power supply 0V + NMEA - NMEA Typical diagram...

 Open the catalog to page 3
Instructions for use CV7-OEM-4

Wind speed range Wind speed resolution Wind speed sensitivity Wind direction range Wind direction resolution Wind direction sensitivity Power requirement Power consumption Boot up delay Dimensions / Sensor Cable Weight / Sensor Operationnal temperature Environement 0.25-40 m/s (0.5 – 80 knots) 0.1 m/s (0.1 knots) 0.13 m/s (0.25 knots) Independent of weather conditions 0-359 ° 1° +/- 1 ° 8 V to 33 V DC 9 mA 4s Cylinder Ø 64 mm - height 61 mm 35 cm standard delivery 4x0.22 mm². 100 gr -15°C to +55°C Sensor IP67 Note: The wind sensors are mounted on an arm of 16 mm diameter by 15 cm length for factory...

 Open the catalog to page 4
Instructions for use CV7-OEM-5

4. NMEA0183 protocol: Baud rate 4800, data bit 8, parity none, stop bit 1 Flux every 512 milli-second Variable lenght fields, delimiter « , ». Start of sentence : $ End of sentence : CR,LF Voltage outputs: 0 or 5V Symmetrical outputs Examples : $IIMWV,225.0,R,000.0,N,A*38 $WIXDR,C,022.0,C,,*52 $PLCJ,5801,5F01,AA,4253,3341 $PLCJEA870,6D98,C500,0056,AC, Wind angle 000.0° to 359.0° Relative reference Sentence formatter Wind Wind speed Wind speed unit N = knots, M= m/s, K=km/h Sentence formatter Temperature of wind CheckSum Status of CV3F A : available, V=Alarm Temperature Unit of measure C = Celsius,...

 Open the catalog to page 5
Instructions for use CV7-OEM-6

- Matiere : POM B anc traite anti UV Material: POM White with UV treatment 6. Warranty Your CV7-OEM is warranted against manufacturing defects in materials and workmanship for a period of 2 years from the date of purchase. LCJ Capteurs will at its discretion, repair or replace faulty product free of charge excluding the cost of shipping. Proof of purchase shall be required in order for a warranty claim. All claims shall be made in writing to LCJ Capteurs and once it is accepted by LCJ Capteurs, the faulty product must be sent to LCJ Capteurs address in Vertou, France. For further information,...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.