Installation
Prepare the mast head for mechanical installation using the provided template for bracket screwing. Align the bracket so the CV7-E sensor faces the bow while the mast is aligned to the North. Fine alignment is achieved through software calibration. Ensure the cable is routed to avoid electromagnetic interference.

Wind Sensor Alignment and Configuration
The CV7-E is pre-configured with NMEA0183, a 2-second filtering, wind force in knots, and temperature in Celsius. Configuration changes can be made using downloadable software from the LCJ Capteurs website. Connection involves red and blue cables for power, and yellow and green for data.

Interconnections NMEA 0183
For RS232 PC input, connect power supply (12V) with red and blue wires, and NMEA data with yellow and green wires. For NMEA 183 standard input (RS422), similar connections apply.

Technical Specifications
The CV7-E operates within a wind speed range of 0.25-40 m/s, with a resolution of 0.1 m/s. It requires 8-33 V DC power and consumes 9 mA. The sensor is IP67 rated and operates between -15°C to +55°C.

NMEA0183 Protocol
The protocol uses a baud rate of 4800, with data sent every 266 milliseconds. Sentences start with '$' and end with 'CR,LF'. Examples include wind angle and speed data formatted in specific sentence structures.

Dimensions
The sensor has a diameter of 63 mm and a height of 61 mm, with an arm length of 300 mm.

Warranty
The CV7-E is warranted for 2 years against manufacturing defects. Claims require proof of purchase and must be sent to LCJ Capteurs in Vertou, France. Proper disposal of electronic equipment is advised.
See more

Catalog excerpts

Instructions for use CV7-E-1

Ultrasonic Wind Sensor LCJ CAPTEURS - ZA le Chêne Ferré 44120 VERTOU – France - Tel 33(0)2 40 05 08 55 [email protected] Reg. 42493307500022 / RCS Nantes – VAT : FR17424933075 Page 1 o

 Open the catalog to page 1
Instructions for use CV7-E-2

1. Installation Prepare the mast head for the mechanical installation. Use the template for the bracket’s screwing. Align the bracket in order to have the CV7-E sensor heading to the bow while the mast is aligned to the North. The sensor’s fine alignment will be obtained with the software calibration application. Run the cable down to the display’s interface, avoiding locations where other cables or equipment may produce electromagnetic interferences. Sensor view from below Bracket mounting template Note :for mounting on vertical surface, the brackets RA106BRACKET and RA106BRACKINOX from Glomex...

 Open the catalog to page 2
Instructions for use CV7-E-3

2. Wind sensor alignment and configuration CV7-E is delivered with the following configuration : NMEA0183® Filtering: 2 s Forces of wind unity : Nds Temperature unity: °C Adjustment of the angle of the wind: 0° To choose other parameters, use the downloadable software on this website: www.lcjcapteurs.com. « Configuration_CV7-C ». Realise the following connexions (only for configuration): SubD 9 points Red cable Blue cable Yellow cable Green cable LCJ CAPTEURS - ZA le Chêne Ferré 44120 VERTOU – France - Tel 33(0)2 40 05 08 55 [email protected] Reg. 42493307500022 / RCS Nantes – VAT :...

 Open the catalog to page 3
Instructions for use CV7-E-4

3. Interconnections NMEA 0183 Realise the following connexions: - For RS232 Type PC input Power supply connections 12V (8 a 30 VDC). Wire Blue - / Wire Red + PC SUBD 9 Pts Plug Type COM1 Soldered side - For NMEA 183 standard input ( RS422) Power supply connections 12V (8 a 30 VDC). Wire Blue - / Wire Red + LCJ CAPTEURS - ZA le Chene Ferre 44120 VERTOU - France - Tel 33(0)2 40 05 08 55 [email protected] Reg. 42493307500022 / RCS Nantes - VAT : FR17424933075

 Open the catalog to page 4
Instructions for use CV7-E-5

4. CV7-E Technical Specifications: Wind speed range Wind speed resolution Wind speed sensitivity Wind direction range Wind direction resolution Wind direction sensitivity Power requirement Power consumption Dimensions / Sensor Boot up delay Cable Arm Cable weight Weight / Sensor + arm and base Weight / Sensor Operational temperature Environement CE Mark 0.25-40 m/s (0.5 – 80 knots) 0.1 m/s (0.1 knots) 0.13 m/s (0.25 knots) Independent of weather conditions 0-359 ° 1° +/- 1 ° 8 V to 33 V DC 9 mA Cylinder Ø 64 mm - height 61 mm 4 seconds 25 m standard delivery 4x0.22 mm². Ø4 mm Aluminium, 300 mm...

 Open the catalog to page 5
Instructions for use CV7-E-6

5. NMEA0183 protocol: Baud rate 4800, data bit 8, parity none, stop bit 1 Flux every 266 milli-second Variable lenght fields, delimiter « , ». Start of sentence : $ End of sentence : CR,LF Voltage outputs: 0 or 5V Symmetrical outputs Examples : $IIMWV,225.0,R,000.0,N,A*38 $WIXDR,C,022.0,C,,*52 $PLCJ,5801,5F01,AA,4253,3341 $PLCJEA870,6D98,C500,0056,AC, Wind angle 000.0° to 359.0° Relative reference Sentence formatter Wind Wind speed Wind speed unit N = knots, M= m/s, K=km/h CheckSum Status of CV3F A : available, V=Alarm Sentence formatter Temperature of wind Temperature Unit of measure C = Celsius,...

 Open the catalog to page 6
Instructions for use CV7-E-7

LCJ CAPTEURS - ZA le Chêne Ferré 44120 VERTOU – France - Tel 33(0)2 40 05 08 55 [email protected] Reg. 42493307500022 / RCS Nantes – VAT : FR17424933075 Page 7

 Open the catalog to page 7
Instructions for use CV7-E-8

7. Warranty Your CV7-Eis warranted against manufacturing defects in materialsand workmanship for a period of 2 years from the date of purchase. LCJ Capteurs will at its discretion, repair or replace faulty product free of charge excludingthe cost of shipping. Proof of purchase shall be required in order for a warranty claim. All claims shall be made in writing to LCJ Capteurs and once it is accepted by LCJ Capteurs, the faulty product must be sent to LCJ Capteurs address in Vertou, France. For further information, please visit www.lcjcapteurs.comwhere video presentations are available. EN 55022...