Catalog excerpts
SHERWOOD SCIENTIFIC FLUID BED DRYER LAB-SCALE, PROGRAMMABLE & ANALYTICAL WITH ALL THE ADVANTAGES OF FLUID BED DRYING FASTMILDNON-AGGLOMERATING REPRODUCIBLEHOMOGENEOUS WITH A LARGE RANGE OF TUB ASSEMBLIES, CONSTRUCTION MATERIALS AND SOFTWARE THE MODEL 501 OFFERS A FLEXIBLE PLATFORM ABLE TO ASSIST WITH; · STUDIES OF MATERIAL DRYING BEHAVIOUR · THE OPTIMISING AND SCALE-UP OF DRYING PROCESSES · PREPARATION OF SMALL SAMPLE BATCHES FOR SUBSEQUENT MATERIAL STUDIES t. +44 (0) 1223 243444 f. +44 (0) 1223 243300 e. enquiries@sherwood-scientific.com w. www.sherwood-scientific.com
Open the catalog to page 1WHAT IS FLUID BED DRYING? By forcing enough gas (air) through a bed of particles, the bed may assume a fluid-like state (resembling a boiling liquid). Heating the incoming air and managing air flow rate through the Model 501 provides thorough mixing and maximum contact of solid with moving air. The result; a process more even and much quicker than conventional drying methods. FAST Delivering up to 2.5m3 per minute of air, the model 501 can break up wet samples, and ensure vigorous mixing and rapid moisture removal. 5 kg of wet “ideal” sample (80% moisture) can be dried in 15 - 20 minutes (5...
Open the catalog to page 2SHERWOOD SCIENTIFIC FLUID BED DRYER FLUID BED DRYERSPECIFYING PROCESS SAMPLE TYPE SYSTEM “REQUIREMENTS” Simple dryer The Sherwood Scientific Model 501 Fluid Bed Dryer is a Lab Scale (Bench Top) dryer with a maximum sample capacity of 5Kg. There is a wide variety of drying tubs (volume and material of construction), inlet & outlet filters, and other accessories available; both to handle as wide a range of sample types as possible and enhance the capability of the drying system. Therefore each system requires specifying in some detail to reflect individual customer requirements and sample...
Open the catalog to page 3SHERWOOD SCIENTIFIC FLUID BED DRYER 1] Model 501 shown with 5 litre glass tub 500 35 008 and large filter bag. Remember to specify tub inlet filter (mesh size and material type) and bag material required. 2] Model 501 shown with 5 litre glass tub with GL32 side port 500 35 010, temperature/humidity probes and large filter bag. Please specify tub inlet filter (mesh size and material type) and bag material required and remember to order the temperature humidity probe 501 86 500. 3] Model 501 shown with 5 litre glass DMA tub 501 35 020 with sealed top-cap assembly and GL32 side port and...
Open the catalog to page 4SHERWOOD SCIENTIFIC FLUID BED DRYER THE BASIC DESIGN The basic Model 501 incorporates an air pump, heating coil, and temperature measurement (with control and timer). Air is drawn through an inlet filter, passed over a heating element and forced through a support filter (which holds the weight of the sample) and a Tub inlet filter (selected for pores smaller than the sample particle size). The air passes through the sample contained within a tub (glass or stainless), and finally through an Outlet filter which can be a Filter Bag. Bag material is selected to be chemically inert to emitted...
Open the catalog to page 5Sherwood Fluid Bed Dryers have been used on hundreds of different sample drying applications, from 10 gms to 5 Kgs. In addition, they have been used to mix solids, form uniform coatings, determine drying parameters, analyse for moisture by weight loss, form fine granular particles from agglomerates, act as a chemical reactor, and classify (separate) particulates by density, size, and surface texture. If your particular drying application is not listed please contact; info@sherwood-scientific.com Substances take up water in two ways External moisture is on the surface of particles and...
Open the catalog to page 6SHERWOOD SCIENTIFIC FLUID BED DRYER WHAT IS FLUID BED DRYING? Drying curves were traditionally generated by sequential weighing over time periodically interrupting the drying process. Using all the features of the 501 fluid bed dryer i.e. in-tub temperature /humidity probe & software, all data can be logged and stored for future reference and subsequent manipulation. Raw data can be manipulated using software to produce drying curves. Inlet air temperature, blower motor speed, in-tub temperature and relative humidity can all be recorded against time (using software and the temperature...
Open the catalog to page 7SHERWOOD SCIENTIFIC PRODUCT RANGE Based in Cambridge, a centre of Scientific Excellence in the UK, Sherwood Scientific Ltd is a manufacturing company with a history of successful innovations and developments designed to provide continual improvement and added value to its product range. Sherwood Scientific Ltd produces a world renowned product range including CHROMA Colorimeters, Flame Photometers and Chloride Analysers; whose origins can be traced back to the 1950s, with continuous Flame Photometers We have a complete range of Flame Photometers; from single channel to multi-channel,...
Open the catalog to page 8All LCI catalogs and technical brochures
-
Marumerizer® Model QJ-700TWG
2 Pages
-
Marumerizer
4 Pages
-
Batch Kneader Model KDAJ-100
2 Pages
-
Batch Kneader
2 Pages
-
Batch Kneader Model KDHJ-20
2 Pages
-
Batch Kneader Model KDHJ-10
2 Pages
-
GMP Circle Feeder™
2 Pages
-
Circle Feeder™
2 Pages
-
THIN-FILM DRYING
2 Pages
-
LCI Lecithin Drying
21 Pages
-
Pelleting Press Model 14-175
2 Pages
-
Kahl Pellet Press
6 Pages
-
LCI Labvap™ Evaporator
2 Pages
-
LCI Sanitary Super Labvap®
2 Pages
-
D‐Velpac® Evaporator
2 Pages