Features:
  • Measurement range: 0-30V d.c.
  • Logging rates: 1 second to 12 hours
  • Storage capacity: 32,510 readings
  • Connection: Two screw terminals
  • Interface: USB for setup and data download
  • Alarm thresholds: User-programmable
  • Status indication: Red and green LEDs
  • Battery: Replaceable internal lithium battery
Ordering Information:
  • Standard Data Logger: EL-USB-3
  • Replacement Battery: BAT 3V6
Specifications:
  • Measurement range: 0-30V d.c.
  • Internal resolution: 50 mV d.c.
  • Accuracy: 1% overall error
  • Operating temperature: -25°C to +80°C (-13°F to 176°F)
  • Battery life: 1 year (dependent on conditions)
Windows Control Software:

The software is compatible with Windows 98, 2000, XP, and Vista (32-bit). It allows setup and data download for the EL-USB-3. The latest version is available at www.lascarelectronics.com.

Data Logger Set-ups:
  • Logger Name
  • Logging Rate (1s, 10s, 1m, 5m, 30m, 1hr, 6hr, 12hr)
  • High and Low Alarms
  • Start Date and Start Time
LED Flashing Modes:
  • Green single flash: Logger primed or logging in progress
  • Red single/double flash: Alarm conditions or low battery
  • Green double flash: Logger full
  • Red/Green single flash: Logger full with alarm condition
Battery Replacement:

Replace the battery every 12 months or before logging critical data. Use only 3.6V 1/2AA lithium batteries. The logger retains data when the battery is discharged or replaced, but logging stops until a new battery is installed and data is downloaded.