Outdoor Preamplifier with Calibration Check For community, traffic or aircraft noise monitoring Highlights n n n n n n Use with Model 831 sound level meter Free-field, random or 90° response using the same microphone and the Model 831 Remote system check simultaneously at five different frequencies Rugged stainless steel construction Internal temperature and humidity sensor Built-in heater with intelligent control to minimize power usage and prevent condensation. Broad temperature range (-40 °C to 70 °C) No desiccants needed Use with EPS2116 Unattended Outdoor Installations Environmental Noise Studies City Noise Monitoring Industrial Noise Monitoring Airport & Traffic Noise Compliant Investigation IEC 61672 Class 1 Compliant Measurements The Larson Davis PRM2103 has been designed to be used with an environmental shroud for portable or permanent outdoor use in a wide range of weather conditions. The PRM2103 combines the cost savings of a standard preamplifier with features for unattended monitoring and an inexpensive shroud to create a product that is ideal for remote sound level measurement. New in the PRM2103 is an automatic calibration check that checks five different frequencies all at the same time which enables better detection of any failure. When used with the Model 831 sound level meter, the acoustic response can be selected as free-field, random or 90 degree using a simple setting on the sound level meter. Because of this flexibility, only one preamplifier is necessary and there is no need to use different microphones for different fields. Because field visits to a remote monitor can be expensive and time consuming, the PRM2103 has been designed to require no routine maintenance. It includes a built-in humidity and temperature sensor and can automatically turn on an internal heater when there is a risk of condensation. All this has been accomplished while keeping power usage low (< 2 mA with heater off) so that the PRM2103 is an excellent solution for battery powered applications. Model EPS2116 Environmental Shroud Model 831 Sound Level Meter Model PRM2103 Preamplifier with Calibration Check Larson Davis

 Open the catalog to page 1
Model 831-2

Electrical Specifications Microphone Bias Input Impedance Max Input Level Max Output Level (typ) Max Output Current Output Impedance Total Harmonic Distortion +N Dynamic Range Power Supply Power (12V) Calibration Check Level Calibration Frequencies Calibration Check Sensitivity Max Cable Length 0 Volts 10 GΩ // 0.1 pF typical ± 18 V peak ± 14 V peak (143 dB peak using 50 mV/Pa mic) 10 mA 50 Ω < -60 dBc at 8 V rms and 1kHz 124 dB ( 16 dB to 140 dB typical A-weighted) 10 V to 15.5 V (12 V nominal) < 2 mA typ, 50 mA max with heater 94 dB ±2 dB (each tone) 31.25, 250, 1000, 4000 & 8000 Hz ± 0.005...

 Open the catalog to page 2

All Larson Davis catalogs and technical brochures

  1. AEC206

    2  Pages

  2. BAS001

    2  Pages

  3. 831-LOWN

    2  Pages

  4. SOUNDADVISOR™

    16  Pages

  5. Model PRM2103

    2  Pages

  6. EPS2116

    2  Pages

  7. NoiseTutor

    4  Pages

  8. System 824

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.