ZMJ60
1Pages

{{requestButtons}}

Catalog excerpts

ZMJ60 - 1

> Technical Data 1. Case diameter: (D64mm 2. Case material: Stainless steel 4. Accuracy: a) Class 1.5 at 20°C; b) Class 2.5 at-40°C to 60°C 5. Ambient conditions: -40°C to +60°C, relative humidity < 95%RH 7. Leakage rate: <1 x 10~9 Pa-m3/s (Helium leakage inspection) 8. Contact type: Magnetic snap-action switch (Maximum three groups, normally open or normally closed, customized by 3 groups according to users' needs) 9. Process connection: M20x1.5 (customizable) 10. Installation method: radial or axial 11. Insulation properties: Insulation resistance: >100 MO (500 V DC) Withstand voltage: 2kV, 50/60 Hz 1 min 12. Contact electrical parameters: Power: 30VA Maximum operating voltage: 380V Maximum current: 1A 14. Pressure element: Bourdon tubes > Description These instruments are used to monitor the density of SF6 gas in sealed tanks and can be widely used in medium voltage switchgear and RMU.They're suitable for outdoor bad external conditions. They can provide multiple solutions to support new substations and the intelligent transformation of existing substations. > Application SFe gas Insulated RMU SF6 gas Insulated Switchgear > Features 1. Volume minimization, customized installation interface, convenient and reliable 2. Pressure interface customized in accordance with customer's demands 3. Utmost three pairs of switching contacts can be provided according to user's needs Lanso Konly (Shanghai) Instruments Co., Ltd. Expert In SF6 Gas Monitoring Solutions

Open the catalog to page 1

All Lanso Instruments Inc catalogs and technical brochures

  1. B36.SA

    2 Pages

  2. ZMJ100PRW

    1 Pages

  3. ZMJ100PRO

    1 Pages

  4. ZMJ100PRDH

    1 Pages

  5. ZMJ100PR

    1 Pages

  6. ZMJ100P

    1 Pages

  7. ZMJ60XD

    1 Pages

  8. ZMJ60R

    1 Pages

  9. RDH

    1 Pages

  10. MONITORING

    1 Pages

  11. MDK

    1 Pages

  12. KL60

    1 Pages

  13. KL50

    1 Pages

  14. HM100PR

    1 Pages

  15. GRE2001

    1 Pages

  16. FMZ

    1 Pages

  17. DT

    1 Pages

  18. DP-01

    1 Pages

  19. DMJ60R

    1 Pages

  20. DM60R

    1 Pages

  21. cv

    1 Pages

  22. ALARM SYSTEM

    1 Pages

  23. Customized2

    1 Pages

  24. Customized1

    1 Pages

  25. magnetic

    1 Pages

  26. dual

    1 Pages

  27. Magnetic

    1 Pages

  28. YSS-100+DS

    2 Pages

  29. YSS-100

    2 Pages

  30. Y-30+DS

    2 Pages

  31. Y-30

    2 Pages

  32. B32.SA

    2 Pages

  33. Precision

    1 Pages

  34. B32.ST+C

    2 Pages

  35. Diaphragm

    1 Pages

  36. B32.ST+DS34

    2 Pages

  37. B32.ST+DS29

    2 Pages

  38. B32.ST+DS27

    2 Pages

  39. B32.ST+DS22

    2 Pages

  40. B32.ST+DS18

    2 Pages