ZMJ100PRW
1Pages

{{requestButtons}}

Catalog excerpts

ZMJ100PRW - 1

J1OOPRW WIRELESS TRANSMISSION RE DENSITY > Description These instruments are used to monitor SF6 gas density in sealed tanks. They are applied to indicate the gas density and to provide a signal outputs when the density reaches the set value. They are able to transmit the real-time data of SF6 gas density remotely and realize the online remote monitoring. They are suitable for monitoring high-pressure system. The SF6 gas density data can be remotely monitored and transmitted by low-power, high anti-interference wireless communication methods. They can provide multiple solutions to support new substations and the intelligent transformation of existing substations. > Application SF6 Gas Insulated Switchgear (GIS) SF6 Insulated Transformers SF6 Insulated Circuit Breakers SF6 Insulated Mutual Inductor SFe Insulated Pole-Mounted Switch SF6 Insulated Busbar Systems > Features 1. The temperature compensation device ensures higher measurement accuracy. 2. Suitable for indoor or outdoor installation 3. AISI 304 hermetically sealed stainless steel case 4. Gas connection tubes are made of AISI 316 stainless steel 5. Wireless communication and convenient for site networking 6. Strong Anti-interference ability and far transmission distance 7. Using concentrator as the center, these instruments can achieve autonomous wireless networking and the concentrator outputs all monitoring data through the RS485. 8. Up to four pairs of contacts can achieve overpressure alarm, dual alarm or double locking and many other options, ensuring the monitoring more secure and reliable > Options 1. Power-frequency withstand voltage: 2.5kV 50/60 Hz 1 min 2. Oil-filled 3. Measuring medium: SF6, Air, N2, SF6 + N2 and other gases Lanso Konly (Shanghai) Instruments Co., Ltd. > Technical Data 1. Nominal Size:100mm 10. Insulation properties: 2. Scale range: -0.1 to 0.9 MPa (customizable) Insulation resistance: >100 MQ (500 V DC) 3. Accuracy: (related to the measuring span SF6 in gas phase) Withstand voltage: 2kV, 50/60 Hz 1 min a) At 20°C: Class 1.0 or 1.5 11. Contact type: b) -40°C to +60°C: Class2.5 Pointer driven magnetic snap action signal contacts; 4. Degree of protection: IP65 80%Ag, 20% Ni, 10pm Au plated 5. Ambient conditions:-40°C to+60°C, relative humidity < 95%RH 12. Impact rating: 50g (oil-filled), 30g (non-oil-filled) 6. Leakage rate: <1 xIO'9 Pa-m3/s (Helium leakage inspection) 13. Contact electrical parameters: 30W/50VA, 1A (maximum) 7. Process connection: M20x1.5 (customizable) 220VDC/380V 50/60Hz (maximum) 8. Installation method: radial or axial 14. Window glass: Laminated safety glass 9. Electrical connection: 15. Weight: 1.2kg Compact pluggable box with M20x 1.5 cable gland 16. Pressure element: Bourdon tubes Cable size: 1.5mm2 recommended, 2.5mm2 maximum 17. Bending AntennaType for indoor, Sucker Amtenna Type for outdoor > Main electrical performance indicators and specifications of the remote transmission part 1. Power supply: DC 24V 2. Power consumption: < 2W 3. Communication mode: RS485 4. Protocol: ModBus RTU 5. Baud rate: 9600bps > Dimensions Expert In SF* Gas Monitoring Solutions

Open the catalog to page 1

All Lanso Instruments Inc catalogs and technical brochures

  1. B36.SA

    2 Pages

  2. ZMJ100PRO

    1 Pages

  3. ZMJ100PRDH

    1 Pages

  4. ZMJ100PR

    1 Pages

  5. ZMJ100P

    1 Pages

  6. ZMJ60XD

    1 Pages

  7. ZMJ60R

    1 Pages

  8. ZMJ60

    1 Pages

  9. RDH

    1 Pages

  10. MONITORING

    1 Pages

  11. MDK

    1 Pages

  12. KL60

    1 Pages

  13. KL50

    1 Pages

  14. HM100PR

    1 Pages

  15. GRE2001

    1 Pages

  16. FMZ

    1 Pages

  17. DT

    1 Pages

  18. DP-01

    1 Pages

  19. DMJ60R

    1 Pages

  20. DM60R

    1 Pages

  21. cv

    1 Pages

  22. ALARM SYSTEM

    1 Pages

  23. Customized2

    1 Pages

  24. Customized1

    1 Pages

  25. magnetic

    1 Pages

  26. dual

    1 Pages

  27. Magnetic

    1 Pages

  28. YSS-100+DS

    2 Pages

  29. YSS-100

    2 Pages

  30. Y-30+DS

    2 Pages

  31. Y-30

    2 Pages

  32. B32.SA

    2 Pages

  33. Precision

    1 Pages

  34. B32.ST+C

    2 Pages

  35. Diaphragm

    1 Pages

  36. B32.ST+DS34

    2 Pages

  37. B32.ST+DS29

    2 Pages

  38. B32.ST+DS27

    2 Pages

  39. B32.ST+DS22

    2 Pages

  40. B32.ST+DS18

    2 Pages