MDK
1Pages

{{requestButtons}}

Catalog excerpts

MDK - 1

DK DENSITY S > Technical Data 1. Scale range: -0.1 to 0.9MPa 9. Insulation properties: 2. Accuracy of set point: ±2.0% (-30-+50 °C) Insulation resistance: >100 MO (DC 500 V) 3. Degree of protection: IP67 Withstand voltage: 2kV, 50/60 Hz 1 min 4. Ambient conditions: 10. Contact type: Mirco contact -30°C to +60°C, relative humidity <95%RH 11. Impact rating: 30g 5. Leakage rate: <1 x 10'9 Pa m3/s (Helium leakage inspection) 12. Contact electrical parameters: 6. Process connection: M20 x 1.5, (customizable) 30W/50VA, 1A (maximum) 7. Installation method: axial 220VDC/380V 50/60Hz (maximum) 8. Electrical connection: Plug-in connection 13. Weight: 0.3kg Cable size: 0.2mm2 to 2.5mm2 14. Pressure element: Bourdon tubes > Description These instruments are used to monitor SF6 gas density in sealed tanks. They are applied to indicate the gas density and to provide a signal outputs when the density reaches the set value. They are designed to monitor High Voltage systems.They can provide multiple solutions to support new substations and the intelligent transformation of existing substations. > Application SF6 Gas Insulated Switchgear (GIS) SF6 Insulated Circuit Breakers SF6 Insulated Pole-Mounted Switch SF6 Insulated Transformers SF6 Insulated Mutual Inductor SF6 Insulated Busbar Systems > Features 1. The Gas compensation ensures higher set point accuracy. 2. The Micro switch enables normally open contacts and normally closed contacts freely switch to each other. 3. High shock resistance 4. Normally closed contacts will not set a false alarm due to vibration 2. Wide temperature range -60°C to +60°C 3. Can detect SF6, Air, N2, SF6 + N2 and other gases Lanso Konly (Shanghai) Instruments Co., Ltd. Expert In SF* Gas Monitoring Solutions

Open the catalog to page 1

All Lanso Instruments Inc catalogs and technical brochures

  1. B36.SA

    2 Pages

  2. ZMJ100PRW

    1 Pages

  3. ZMJ100PRO

    1 Pages

  4. ZMJ100PRDH

    1 Pages

  5. ZMJ100PR

    1 Pages

  6. ZMJ100P

    1 Pages

  7. ZMJ60XD

    1 Pages

  8. ZMJ60R

    1 Pages

  9. ZMJ60

    1 Pages

  10. RDH

    1 Pages

  11. MONITORING

    1 Pages

  12. KL60

    1 Pages

  13. KL50

    1 Pages

  14. HM100PR

    1 Pages

  15. GRE2001

    1 Pages

  16. FMZ

    1 Pages

  17. DT

    1 Pages

  18. DP-01

    1 Pages

  19. DMJ60R

    1 Pages

  20. DM60R

    1 Pages

  21. cv

    1 Pages

  22. ALARM SYSTEM

    1 Pages

  23. Customized2

    1 Pages

  24. Customized1

    1 Pages

  25. magnetic

    1 Pages

  26. dual

    1 Pages

  27. Magnetic

    1 Pages

  28. YSS-100+DS

    2 Pages

  29. YSS-100

    2 Pages

  30. Y-30+DS

    2 Pages

  31. Y-30

    2 Pages

  32. B32.SA

    2 Pages

  33. Precision

    1 Pages

  34. B32.ST+C

    2 Pages

  35. Diaphragm

    1 Pages

  36. B32.ST+DS34

    2 Pages

  37. B32.ST+DS29

    2 Pages

  38. B32.ST+DS27

    2 Pages

  39. B32.ST+DS22

    2 Pages

  40. B32.ST+DS18

    2 Pages