Overview: The document provides detailed information about the Lanemark TX Tank Heating Systems, which are high-efficiency, small-diameter immersion tube systems designed for heating process liquids in various industrial applications.
Specifications:
  • Fuels: Natural gas and Propane.
  • Control Voltages: 230V and 110V.
  • Exhaust Fan Electrical Supplies: 400V/3ph/50Hz and 230V/1ph/50Hz.
  • Flame Sensing: Flame electrode and UV scanner.
  • Heat Output Control Options: On/off, High/low, and Modulating.
Applications:
  • Product Finishing: Includes processes like degreasing, phosphating, and anodising.
  • Cleaning: Used in industrial washing machines, crate washers, and bottle washers.
  • Food and Drink Production: Suitable for hot water tanks, mini brewery wort coppers, and CIP tanks.
Model Specifications:
  • TX15: 45 kW (150,000 Btu/h)
  • TX20: 80 kW (275,000 Btu/h)
  • TX25E: 140 kW (475,000 Btu/h)
  • TX30: 220 kW (750,000 Btu/h)
  • TX40: 440 kW (1,500,000 Btu/h)
  • TX60: 730 kW (2,500,000 Btu/h)
Advantages:
  • High operating efficiencies (≥80% gross, ≥90% net calorific value).
  • Minimal tank space requirement, allowing for smaller tanks and easy retrofitting.
  • Compatible with Lanemark TRX burner systems for multiple burner arrangements.
  • Low gas supply pressure operation and suitable for rubber-lined or fiberglass tanks.
Compliance and Support: TX burners conform to European Standard EN 746 Part 2. Lanemark offers BurnerCare support, including commissioning, spare parts supply, and system training.
Additional Products: Lanemark also offers the TRX range for smaller operations and the FD range for process air heating.
See more

Catalog excerpts

TX Tank Heating System-1

Lanemark TX series high efficiency, small diameter immersion tube tank heating systems offer end users the most cost effective method of heating process liquids which are used in many areas of industry. Specific advantages compared with alternative tank heating methods -0 Low operating costs - operating efficiencies of >80% gross calorific value >90% net calorific value 0 TX small diameter immersion tube heat exchangers occupy minimal tank space. This enables smaller tanks to be used for new plant designs and allows simple replacement of other heating systems for retrofit applications. TX immersion tubes can be configured in multi-pass shapes to ensure that they remain well clear of internal tank fittings or processing areas. 0 Tank heat input and immersion tube performance calculations are easily carried out using Lanemark’s dedicated design software. 0 Heat exchangers can be configured to fit rectangular tanks and horizontal or vertical cylindrical tanks utilising helical coil heat exchanger arrangements where necessary. 0 Induced draught combustion air arrangement allows multiple burner systems to be connected to a common flue, retaining individual burner control. 0 Simple heat exchanger installation requires only two pipe flange drillings, usually in one tank wall. 0 Operates with low gas supply pressures. 0 Firing into rubber lined or fibre glass tanks is permitted due to low initial heat exchanger surface temperatures at tank connection. 0 Fully compatible with Lanemark TRX burner systems so that they may be incorporated into schemes where multiple TRX/TX burner arrangements are required. Typical Applications 0 Cleaning (industrial washing machines) - Plastic crate washers - Parts washers - Bottle washers 0 Food and Drink Production - Hot water tanks - Mini brewery wort coppers - Cleaning in place (CIP) tanks - Animal scalders - Blanchers 0 Product finishing (metal parts, steel strip, wire products, etc.) - Pre-treatment and treatment processes including: alkali/caustic degreasing phosphating hot water rinsing aluminium etching anodising borax and lime coatings - Dip tanks - Spray systems - Hot water supply systems TX burners conform with European Standard EN 746 Part 2 as appropriate and are pre-wired and tested prior to despatch. A modular Lanemark TX immersion tube burner system includes a cylindrical burner assembly built to withstand typical tank heating operating environments, a compact monobloc valve gas train, burner controls mounted in a protective control box (which can include a digital temperature controller), exhaust damper and an exhaust fan which can be coupled to multiple TX/TRX burner installations. Standard equipment Fuels Control voltages Exhaust fan electrical supplies Flame sensing Heat output control options ____ TX TANK HEATING SYSTEMS

 Open the catalog to page 1
TX Tank Heating System-2

DIMENSIONS D E F G Acids I I Phosphates I I Detergents I I Chromates I ------------ Tw^n^vT Tvv%^vs,x Beers I I Water I I minWaaesed I I ^ts | All dimensions in mm, except where stated. lANEMARK All TX burners benefit from Lanemark’s BurnerCare customer support. BurnerCare services include burner system commissioning/start-up, supply of spare parts and system training. BurnerCare will provide a contract service plan and a rapid response facility, designed to ensure the continued and reliable operation of Lanemark equipment worldwide. Also available from Lanemark is the TRX range of low...

 Open the catalog to page 2

All LANEMARK COMBUSTION ENGINEERING LTD catalogs and technical brochures

  1. KS Burners

    6  Pages

  2. FD-E Burners

    2  Pages

  3. FD-C Burners

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.