Catalog excerpts
Since 1981 Lanemark International has played a leading role in the specialised field of fired heaters for petrochemical, refining and related applications. Today the company's International Combustion Division has developed close working relationships with the leading companies in this industry, and can demonstrate technology which maximises both hydrocarbon processing performance and environmental protection. In all cases the burner design is centred around the ‘Thermimax' matrix burner head which provides the optimum mixing of fuel and combustion air to meet the specific requirements of each application. This, coupled with Lanemark's commitment to combining research and development with practical experience, delivers equipment that maximises reliability and efficiency whatever the process or performance objectives. Typical Process Applications • Hydrogen • Methanol • Ammonia Advanced patented design provides -• Multi-fuel combustion on a single burner head • Optimum combustion efficiency • Low emission and noise levels • Adjustable flame profiles • Combustion air temperatures up to 500°C • Wide range of pressures for both fuel and combustion air • Complete flame stability under all operating conditions • Direct spark or pilot flame ignition - portable or permanent • Robust construction with no moving parts • Induced Draught options available - features that embody quality, reliability and flexibility
Open the catalog to page 1# Operation over a wide range of gaseous fuels Natu rai # Fuel gas supply pressures from 10 mbar - 4 bar g # Combustion air pressure drop 2 mbar - 60 mbar # Excess air levels from 0.5% to 500% # Combustion air temperature from ambient to 500°C # NOx emission <45 ppm reference to 3% O2 (dry) # CO emission <10ppm # Noise (sound pressure level) <70 dB(A) measured one metre radially from the back of the burner # Fuel turn-down with combustion air modulation V - up to 10 : 1 • Fuel Turn-down with fixed combustion air \ - up to 4 : 1 Operating Principle Others 5% Central to the performance...
Open the catalog to page 2Standard Forced Draught Burner Dimensions (HC 224 & HC 260) Optional damper Flame view port Fuel pressure test point Air pressure test point Ignitor guide tube All dimensions are in mm and can be varied to suit application requirements HC Burner Features q A single, purpose-designed burner head accommodates all combinations of gaseous fuels and operating cases without the need to change burner components q Smooth, reliable ignition across the burner head under all operating conditions q Excellent flame stability due to the ‘Thermimax’ matrix design q Direct, portable spark ignition for...
Open the catalog to page 3HC SERIES MATRIX BURNERS Lanemark burners have been specified by many of the world’s leading Petrochemical Process Design Houses and Constructors, including – Linde AG Selas Linde GmbH Selas Fluids Processing Corporation Jacobs Engineering Humphreys and Glasgow Technip/KTI Lurgi Öl Gas Chemie Kvaerner Process Technology Davy Process Technology John Brown Constructors Krupp UHDE Foster Wheeler Howe-Baker Mahler AGS Additional Burner Products The Lanemark HC 260 and HC 224 burners illustrated in this brochure are purpose designed to meet specific requirements within the industry....
Open the catalog to page 4All LANEMARK COMBUSTION ENGINEERING LTD catalogs and technical brochures
-
TRX Series Burners
2 Pages
-
Duct Burners (DB Series)
2 Pages
-
TX Series Burners
2 Pages
-
KS Burners
6 Pages
-
Lanemark DB Duct Burners
2 Pages
-
Lanemark Midco Burners
2 Pages
-
TX Tank Heating System
2 Pages
-
FD-E Burners
2 Pages
-
FD-C Burners
2 Pages
-
MTX Series Burners
2 Pages
-
Lanemark TRX series
2 Pages
-
KS SERIES Product Range
1 Pages
-
HC burner series
4 Pages
-
FD-C (GA) Burners
2 Pages
-
FD-E (GA) Burners
2 Pages