FD-C Burners
2Pages

{{requestButtons}}

Catalog excerpts

FD-C Burners - 1

FD-C series burners are particularly suited to direct-fired applications and can be mounted directly on to the wall of a dryer, oven or process air heating duct to operate either in line with or at 90˚ to the process air flow. FD-C series burners produce short flame profiles – so important for industrial oven design. Combustion air and gas is progressively mixed within the internal burner cone assembly, guaranteeing stable combustion over a wide range of oven/dryer process air flows. Burner turn-down is determined by the ratio of the high and low gas firing rates. The maximum turn-down ratio is 40:1. Lanemark FD-C series packaged burners are specifically designed to offer flexible, high turn-down (gas only) control for process air heating applications in convection ovens and dryers. l Textile and fabric dryers machines l Food processing grain dryers FD burners conform with European Standard EN 746 Part 2 as appropriate and are pre-wired and tested prior to despatch. Specifications The standard FD-C burner comprises a burner windbox including a protective burner cowl, combustion air fan, a manual sliding damper fitted between the combustion air fan and the air entry flange on the burner windbox, a compact monobloc valve gas train and gas burner controls mounted in a control box. Standard control items include a burner controller, ignition transformer and differential air pressure switch. Two 3-way air valves perform safety checks on the air pressure switch in both open and closed modes each time the burner fires, allowing the independent operation of the combustion air fan in conjunction with oven/dryer main recirculation fans. Fuels 4 atural gas N Control voltages 4 30V 2 Combustion air fan electrical supplies 4 00V/3ph/50Hz 4 Flame sensing 4 lame electrode F Protection 4 Burner cowl 4 ontrol box C Heat output control options 4 n/off O or 4 igh/low H l odulating (gas only) M Either 3 wire valve positioning (24/110/230V) or 4 - 20mA or 0 - 10V DC Typical Applications l Product finishing ­ – Pre-treatment dryers ­ inal treatment –F ovens for paint drying – onveyor and C batch ovens

Open the catalog to page 1
FD-C Burners - 2

FD-C BURNERS Front Face Side View DIM 'B' A/F BURNER / TUBE FLANGES DIM 'H1' Hi/Lo Control DIM 'H2' odulating Gas M Ø 'X1' Flame Tube Ø 'X2' ombustion Tube C OVEN HOLE BURNER DEPTH DIM 'R' FAN HEIGHT SERVICE CLEARANCE SERVICE CLEARANCE BURNER HEIGHT Oven Mounting Details 8 STUDS M'P' x 35 LONG EQUI-SPACED AS SHOWN DIM 'W' COMBUSTION TUBE (OPTIONAL SUPPLY) DIM 'E' GAS INLET SIZE 'K' BSP FEMALE A B C D E F G H1 H2 J K L M N P R S T V W X1 X2 Net Gross Weight Weight mm mm mm mm mm mm mm mm mm mm "BSP mm mm mm Stud mm mm mm mm mm mm mm kg kg FD5-C Ø150 230 200 385 100 220 360 360 460 340 9-117...

Open the catalog to page 2

All LANEMARK COMBUSTION ENGINEERING LTD catalogs and technical brochures

  1. KS Burners

    6 Pages

  2. FD-E Burners

    2 Pages