Technical Data Combination Probe KS1D-HT Fig. 1-1 Combination probe KS1D-HT with flue gas bypass tube Fig. 1-2 Dimensional drawing Combination Probe KS1D-HT (high temperature) with flue gas bypass tube Combination Probe KS1D-HT high temperature type 656R2015 Flange seal Novaphit type 656P0263 Flange seal graphite type 655P4211 Counter flange with tube socket KTL coated type 655R0179 or Counter flange with tube socket stainless steel 1.4571 type 655R0180 Flue gas temperature at the probe head max. 300 °C in connection with LT3-F Flue gas temperature at the probe head max. 450 °C in connection with LT3 and LT2 Flue gas bypass tube Gas velocity: < 10 m/s at a length of > 1,000 mm < 30 m/s at a length of 1,000 mm From 16 m/s on with increasing accuracy! 10 Length 500 ... 2,000 mm 11 Hose connection 4/6 mm (0.02 in.) for calibration gas 12 Connecting cable with plug, length 2 m (6.6 ft
Open the catalog to page 1Technical Data Combination Probe KS1D-HT (+) probe signal O2/ COe (black) (-) probe signal COe (grey) probe heating (white) probe heating (white) (-) probe signal O2 (red or blue) Fig. 1-4 Dimensions of counter flange with tube socket
Open the catalog to page 2Information according to EN 16340:2014 D Test report LTC-14-IB-09-V1.0 upon request O2: Information assumes an operating gas composition of 5 vol. % O2, rest is N2 COe: Information assumes an operating gas composition of 5 vol. % O2, 333 ppm COe, rest is N2 (333 ppm COe = 166.5 ppm H2 + 166.5 ppm CO)
Open the catalog to page 4According to DIN V 18160-1:2006-01, seal tightness towards environment through housing and fastening. EN 16340:2014 D approval (in connection with LT3-F) only with gaseous and liquid fuels In connection with LT3-F max. 300 °C permissible flue gas temperature on probe head. The flue gas temperature can be considerably higher since it is reduced by the correctly selected length of the flue gas bypass tube.
Open the catalog to page 5Technical Data Combination Probe KS1D-HT Fig. 1-5 Flue gas bypass tube delay time as function of the velocity in the exhaust air channel depending on the varying lengths of the flue gas bypass tube The figure shows the delay time tEGDT [s] resulting from the length of the flue gas bypass tube LEGDT [mm] as a function of a flow velocity in the middle of the flue air channel v [m/s].
Open the catalog to page 6Order Information Combination Probe KS1D-HT for simultaneous measurement of oxygen (O2) and unburnt residue (CO/H2) in combination with bypass tube for flue gas temperatures up to 1200 °C (2192 °F) Description / Type Combination Probe KS1D-HT "high temperature”, cable length 2 m (6.6 ft.), IP65 Flue gas bypass tube 70 mm, material: stainless steel 1.4571, for measuring gas temperatures up to 750 °C (399 °F) Type Flue gas bypass tube 60 mm, material Inconel 600 for measuring gas temperatures up to 950 °C (1742 °F) Type Flue gas bypass tube 60 mm, material Kanthal for measuring gas...
Open the catalog to page 7All Lamtec catalogs and technical brochures
-
F130I
4 Pages
-
ETAMATIC
7 Pages
-
KS1D-Ex
3 Pages
-
KS1D without Housing
4 Pages
-
KS1D in Housing
5 Pages
-
KS1 without housing
4 Pages
-
High Dust Mounting Flange
2 Pages
-
BT300
5 Pages
-
GKI300
3 Pages
-
BurnerControl FA1
4 Pages