TRiCATT G

TRiCATT G

TRiCATT G

Product catalog summary
Overview
The TRiCATT is a compact, lens-coupled image intensifier designed for scientific and industrial applications requiring low-light imaging, ultra-short exposures, and frequency-domain imaging. It features an 18 or 25 mm image intensifier compatible with CCD or CMOS cameras, offering high sensitivity and flexibility.

Specifications
The TRiCATT supports Gen II and Gen III image intensifiers, providing high sensitivity down to single photon levels. It offers various models with different spectral sensitivities, phosphor types, spatial resolutions, and gating frequencies. The fast gate unit allows operation up to 2.5 MHz in burst mode.

Key Features
  • High-resolution image intensifiers with Gen II and Gen III options.
  • Small gate widths down to less than 3 ns with minimal jitter.
  • High gate repetition rates up to 300 kHz/2.5 MHz burst.
  • Compact design for easy integration.
  • Overexposure protection with user-definable current limitation.
  • Flexible lens coupling to CCD and CMOS cameras.

Applications
TRiCATT is suitable for time-resolved imaging, spectroscopy, particle image velocimetry, laser-induced fluorescence, fluorescence lifetime imaging microscopy, and more.

Image Intensifier Layout
The TRiCATT system includes components such as the image intensifier, relay lens, camera, gate unit, MCP power supply, and gate input. The system converts incoming light to electrons, amplifies them, and reconverts them to photons.

Image Intensifier Specifications
TRiCATT offers models with different input diameters, window thicknesses, and effective areas. It supports various photocathodes and provides high luminous gain and resolution.

Gating
The TRiCATT G model functions as an ultra-fast electro-optical shutter, allowing user-defined pulse widths and frequencies. It includes control units for gain and gate control, with options for programmable gate patterns.

Control Units and Gating Properties
Different control unit models offer features like gain control, gate control, and internal trigger generation. They support various pulse widths, repetition rates, and delay jitters.

Modulation Specification
The TRiCATT M model supports frequency-domain imaging with modulation frequencies from 100 kHz to 120 MHz. It includes a modulation control unit for precise frequency and phase adjustments.

Dimensions and Operating Conditions
The TRiCATT models vary in weight and are designed to operate within specific temperature and humidity ranges.

Mechanical Shutter
An optional mechanical shutter is available to protect the image intensifier from high-intensity light. It can be controlled via remote or software.

Contact Information
For more details, visit Lambert Instruments' website or contact their sales team.
See more

Catalog excerpts

TRiCATT G-1

Time-Resolved Intensified Camera Attachment The TRiCATT is a compact lens-coupled image intensifier for scientific and industrial applications that require 1) low-light level imaging, 2) ultra-short exposures through fast gating, and/or 3) frequency-domain imaging using lock-in detection. The TRiCATT features an 18 or 25 mm image intensifier with a highly efficient relay lens that can be matched to any CCD or CMOS camera, resulting in a flexible solution that can easily be integrated in an existing imaging system. The TRiCATT (Time Resolved intensified Camera Attachment) is the best choice for ultra-fast imaging in the time domain and/ or frequency domain. With a wide range of Gen II and Gen III image intensifiers, the TRiCATT offers high sensitivity down to single photon level and the optimal spectral bandwidth for your application. Different models covering a range in spectral sensitivity, phosphor, spatial resolution, gain, linearity, minimum gate width and gating frequency are available. For time-domain imaging the intensifier is equipped with a fast gate unit (TRiCATT G40n/G2n) that enables the intensifier to operate as an electro-optical shutter. The gate unit can be operated up to repetition rates of up to 2.5 MHz in burst. KEY FEATURES High resolution image intensifiers Gen II and Gen III image intensifiers offering the world’s highest resolution and sensitivity in the UV, visible or near infrared Small gate widths Gate width down to less than 3 ns (FWHM) with minimal jitter High gate repetition rates Up to 300 kHz/2.5 MHz burst Compact design For an easy fit to your imaging or spectroscopy setup Overexposure protection User-definable current limitation and optional shutter A series of different intensifier control units provide functionality ranging from analog gain control to full digital control including an internal trigger generator and programmable gate trains. For frequency-domain imaging the TRiCATT M supports gain modulation of 120 MHz (standard) and higher (external signal generator). Modulation is provided by a single-chip digital synthesizer to ensure an extremely low phase noise. APPLICATIONS Time-resolved imaging and spectroscopy Particle Image Velocimetry (PIV) Laser Induced Fluorescence (LIF) Time-gated luminescence Fluorescence Lifetime-Imaging Microscopy (FLIM) Förster Resonance Energy Transfer (FRET) Oxygen imaging Viscosity imaging Single-molecule imaging Bio- and Chemiluminescence Imaging Solar PV and LED characterization Combustion Time-gated Raman Plasma physics X-ray Imaging Easy coupling Flexible and efficient lens coupling to any CCD and CMOS camera (up to 500 fps) Specifications are subject to change without prior notice.

 Open the catalog to page 1
TRiCATT G-2

Image Intensifier Layout b a) light b) image intensifier c) relay lens d) camera e) gate unit f ) MCP power supply g) gate input (TTL) When the TRiCATT is mounted to a lens or microscope, the incoming light (a) is focused onto the entrance window of the image intensifier (b). The image intensifier converts the optical image to electrons at the photocathode, amplifies this electron image at the micro-channel plate (MCP), and re-converts the electrons into photons at the anode screen. At the output of the intensifier, a relay objective is mounted with a magnification that matches the intensifier...

 Open the catalog to page 2
TRiCATT G-3

The TRiCATT G can be used as an ultra-fast electro-optical shutter by gating the image intensifier. This eliminates motion blur and reduces the effective exposure time, thereby significantly widening the camera dynamic range. To prevent loss of intrascene dynamic range when using a shorter gate the user can set a higher MCP gain. The pulse width and frequency are user defined: any pulse width from DC down to a few nanoseconds can be applied. The intensifier gate generator is optionally available with programmable gate patterns. A frame storage facility allows storing many different delay/width-settings...

 Open the catalog to page 3
TRiCATT G-4

intensifier manual gain control Camera Power supply Shutter control Intensifier manual gain control External gate delay generator Sync signal intensifier gain control Shutter control Intensifier gain control External gate delay generator Sync signal Power supply intensifier gate control Camera Sync signal Shutter control Intensifier gate control / generator* Power supply or external ( trigger source ) *The intensifier gate generator can also operate as master trigger source for camera, intensifier and other devices

 Open the catalog to page 4
TRiCATT G-5

Spectral response and phosphor decay time Q.E.=50% Q.E.=45% GaAsP enhanced red GaAs Modulation control unit The TRiCATT M provides highly accurate frequency-domain imaging with high-resolution gain modulated Gen II and Gen III image intensifiers. The TRiCATT M combines the image intensifier with a separate modulation control unit. The modulation control unit contains a single-chip dual channel DDS for generation and amplification of two RF modulation signals, one for the modulated lightsource or acousto-optic modulator (AOM) and one for the image intensifier (100 kHz – 120 MHz standard). The...

 Open the catalog to page 5
TRiCATT G-6

MODULATION SPECIFICATION TRiCATT M Frequency range 100 kHz–120 MHz (standard) Up to at least 250 MHz with an external signal generator Frequency adjustment resolution Frequency deviation Phase adjustment range 0–360° in 1° steps, phase deviation < 0.01° Harmonics suppression High light level protection Integrated intensifier protection, switches off all DC and AC power Output 1. TRiCATT AC signal level AC signal after amplification Output 2. Lightsource Programmable options: a) Multi-LED AC signal level b) Modulated laser diode AC signal level c) AOM for CW laser AC signal level Half the frequency...

 Open the catalog to page 6
TRiCATT G-7

DIMENSIONS AND OPERATING CONDITIONS TRiCATT 25 with 1:1 relay lens Supply voltage Operating temperature Operating humidity (non-condensing) TRiCATT 25 with 2:1 relay lens Supply voltage Operating temperature Operating humidity (non-condensing) TRiCATT 18 with 1:1 relay lens Supply voltage Operating temperature Operating humidity (non-condensing)

 Open the catalog to page 7

All Lambert Instruments catalogs and technical brochures

  1. HiCAM_Fluo

    4  Pages

  2. Toggel

    2  Pages

  3. Lambert HS540

    2  Pages

  4. HiCAM Fluo

    4  Pages

  5. TRiCATT M

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.