VIT-FIT high-pressure syringe pump - infusion pump - Leaflet

VIT-FIT high-pressure syringe pump - infusion pump - Leaflet
1 /3Pages

Catalog excerpts

VIT-FIT high-pressure syringe pump - infusion pump - Leaflet-1

VIT-FIT and VIT-FIT HP Lab syringe pump - infusion pump The LAMBDA VIT-FIT and VIT-FIT HP high-pressure and highspeed syringe pumps are mechanically robust with highest precision of the flow rates. o o o o o o o o o o o o o o Syringe type: Any plastic, metal or glass syringes Volume of the syringes: μl to ~150 ml Flow rate range: 0.4 nl/min (5 l syringe) to 6.6 l/h (150 ml syringe) Metal chassis: Not affected in case of accidental spills or syringe leakages Swiss quality motor and ball screws for an efficient force transmission with highest mechanical load capacity of 12’000 N Precise flow rates and very high forces of 80 or 300 N (160 or 600 N for VIT-FIT HP) Pusher arm does not reach out Infusion / withdrawal pump (push / pull) Dispensing accuracy of ± 1% Motor stall detection Automatic switch off when the syringe is empty or has been refilled Suitable for high-pressure, high-speed & counter pressure applications; handling of viscous liquids in the laboratory Valve control for continuous operation PC controlled or stand-alone; TTL signal based control; footswitch

 Open the catalog to page 1
VIT-FIT high-pressure syringe pump - infusion pump - Leaflet-2

Construction advantages The combination of a high quality and long-life Swiss motor and ball screws with an extreme mechanical robustness (of 12’000 N which is the force to lift 15 persons!) provide the VIT-FIT syringe pump an unprecedented power and high precision of the syringe pusher movement and the resulting flow rate. Spill protection of the precision ball-screw mechanics Intuitive control panel; flow rate programming; maximum speed filling / emptying New syringe fixing system for almost any syringe, µL to ~150 ml Pusher arm does not reach out; maximum filling adjusted by a screw Quality...

 Open the catalog to page 2
VIT-FIT high-pressure syringe pump - infusion pump - Leaflet-3

Technical specifications Type Programming Time resolution Accuracy Reproducibility Syringes Flow rate range Minimum: Maximum: Maximum force Motor Transmission Pusher travel Pusher travel rate Speed control range Non-volatile memory Power supply Interface Remote control Dimensions Weight Safety Operation temperature Operation humidity LAMBDA VIT-FIT – microprocessor-controlled programmable syringe pump (infusion / withdrawal) Up to 99 steps of speed and time 0 to 999 minutes in 1 minute steps OR 0 to 99.9 minutes in 0.1 minute steps (time resolution can be selected individually for each program...