Product catalog summary
Overview: The document presents an easy-to-use and economical solution for switching vessel volumes using a single instrument. It highlights the benefits of using threaded glass vessels with screw caps for maintaining sterility and introduces a novel non-rotational bio-mixing technique.
Key Features:
  • Interchangeable Volumes: Allows for switching vessel volumes ranging from 35 ml to over 61 ml with one instrument.
  • Sterility Maintenance: The threaded glass vessel with screw caps ensures easy and long-term sterility maintenance.
  • Bio-Mixing Technique: The novel non-rotational bio-mixing method eliminates vortex formation, removing the need for baffles.
Reasons for Eliminating Head Plates:
  • Complicated setup and cleaning process.
  • Expensive spare parts and time-consuming setup.
  • Difficulties in making tight connections due to shallow threads.
  • Limited number of ports and the need to replace O-rings before each run.
  • Contamination risks due to O-ring flattening during sterilization.
  • Requirement for new head plates for each new vessel size.
Challenges with Large Vessels: Large vessels incur high medium costs, downstream costs, long sterilization and cooling times, and difficulties in disposing of infective material.
See more

Catalog excerpts

Elimination of expensive head plates in MINIFOR bench-top fermentor and bioreactor-1

EASY-TO-USE AND ECONOMICAL SOLUTION Switch volumes at low cost Interchange vessel volumes (35 ml to over 61) with just one instrument Threaded glass vessel with screw caps ~.. . Setting up is as easy as screwing a cap on the ·4 ; ,f bottle Unique sterility concept Assures a perfect & easy sterility maintenance for a long time Novel non-rotational bio-mixing Produces no vortex which eliminates the need of baffles WHY LAMBDA ELIMINATED HEAD PLATES? LIMITED number of ports REPLACE O-rings before each run setting up ~ & cleaning process ~ EXPENSIVE spare parts CONTAMINATION due to flattening of O-rings during sterilization TIME consuming set-up NEED new head plates ~ (probes, O-rings, nuts..) ~ for each new vessel size ~ DIFFICULT to make tight connection with shallow threads E;1 LARGE VESSEL = high medium cost + downstream cost + long sterilization & cooling time + .. difficulty in disposing infective material

 Open the catalog to page 1

All LAMBDA Laboratory Instruments catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.