Rox™ RTDs ■ Standard curve interchangeable ■ Good radiation resistance induced errors ■ Standard curve interchangeable ■ Good radiation resistance field-induced errors over other ruthenium oxides ■ Standard curve interchangeable ■ Good radiation resistance interchangeability from induced errors Ruthenium Oxide (Rox™) RTDs Ruthenium oxide temperature sensors are thick-film resistors used in applications involving magnetic fields. These composite sensors consist of bismuth ruthenate, ruthenium oxides, binders, and other compounds that allow them to obtain the necessary temperature and resistance characteristics. Each Lake Shore Rox™ model adheres to a single resistance versus temperature curve. temperature) is useful down to 50 mK and has better interchangeability than the RX-202A as well as low magnetic field- induced errors below 1 K. temperature) is useful down to 10 mK (calibrations available down to 20 mK) unique package design maximizes thermal connection and minimizes heat capacity magnetic fields. in magnetic field-induced errors over other commercially available ruthenium oxide temperature sensors with similar resistances and sensitivities. Most ruthenium oxide sensors have a maximum useful temperature limit well below room temperature, where the sensitivity changes from negative to positive. The RX-202A however, is designed to have a monotonic response from 0.05 K up to temperature) has a unique resistance and temperature response curve combined with low magnetic field- induced errors, and is the best choice for Typical Rox™ Resistance Values Typical Rox™ Sensitivity Values Typical Rox™ Dimensionless Sensitivity Values Lake Shore Cryotronics, Inc. e-mail: info@lakeshore.com
Open the catalog to page 1Rox™ RTDs Magnetic Field Dependance Data for Sample Rox™ RTDs Physical Specifications !LI Lii. IAJJIL-J f' ■U IJ/ HI |jAJ lAli' UIA.4 JJLI^ILI ILL: Lake Shore Cryotronics, Inc. e-mail: info@lakeshore.com
Open the catalog to page 3Rox™ RTDs For information on mounting adapters and packages available for Rox™ sensors, see page 25. Rox™ RTD Calibration Range Suffix Codes Numeric figure is the low end of the calibration Letters represent the high end: C=1 K, B=40 K, M = matched (calibration of matched sensors is available – consult Lake Shore) Uncal 0.02C 0.02B RX-102B-CB RX-102A-AA-M RX-103A-BR RX-103A-AA-M RX-103A-AA, CD RX-102A-BR 1.4B 0.3B RX-102A-AA, CD 0.05B RX-202A-AA-M The Rox™ 202A, 102A, and 103A sensors are available in the Lake Shore standard copper AA canister and the 102B is available in the CB copper...
Open the catalog to page 4All Lake Shore Cryotronics catalogs and technical brochures
-
Model 224 Temperature
6 Pages
-
GaAlAs Diodes*
3 Pages
-
DT-670 Silicon Diodes
5 Pages
-
7600
20 Pages
-
8404
24 Pages
-
Model 625
5 Pages
-
100 Series
3 Pages
-
Model 218
4 Pages
-
Model 211
4 Pages
-
Model 370
10 Pages
-
Thermocouple Wire
1 Pages
-
Germanium Sensors
4 Pages
-
Cernox Sensors
4 Pages
-
Rhodium Iron Sensors
3 Pages
-
Platinum Sensors
3 Pages
-
GaAlAs Sensors
3 Pages
-
DT 670
4 Pages
-
DT 400 Sensors
4 Pages
-
Magnetics Catalog
64 Pages
-
Temperature Catalog
232 Pages