Catalog excerpts
Smart Technology. Delivered.™
Open the catalog to page 12 Laird designs and manufactures customized, performance-critical products for wireless and other advanced electronics applications. The company is a global market leader in the design and supply of electromagnetic interference (EMI) shielding, thermal management products, signal integrity components, antenna solutions, as well as radio frequency (RF) modules and wireless remote controls and systems.
Open the catalog to page 2PCR Cycler System CYCLER MODULE The cycler module assembly is precision manufactured using Lairds thermoelectric devices and quality materials in a form that is suitable for many cycling applications. An RTD is incorporated into the design which monitors and provides feedback of surface temperature. The cycler module can be removed and integrated into an actual PCR cycling system under development as a means of securing test samples to the active surface for trial. See section covering Cycler Module Off System Operation. CYCLER BASE The cycler base is a stand alone table top display for...
Open the catalog to page 3Cycler Assembly USAGE The Removable Black Ultem adapter is a place holder for sample attachment. The Heat spreader is the controlled side of the Cycler Module. Connectors J1, J2 and J3 must be connected to corresponding cable connections. Controller This controller kit is intended for evaluation purposes. Specification Physical Dimensions Voltage Source Requirements Input Voltage Input Power With ambient temperature of 25°C With ambient temperature of 25°C Load and heat sink 4 Laird designs and manufactures customized, performance-critical products for wireless and other advanced...
Open the catalog to page 4Smart Technology. Delivered. SYSTEM REQUIREMENTS Memory - SD card slot FRONT VIEW Alarm - Relay contacts Laird designs and manufactures customized, performance-critical products for wireless and other advanced electronics applications. The company is a global market leader in the design and supply of electromagnetic interference (EMI) shielding, thermal management products, signal integrity components, antenna solutions, as well as radio frequency (RF) modules and wireless remote controls and syste
Open the catalog to page 5Wires as required not to exceed 5Amp Micro USB AB cable (Similar to A to Left Angle Micro B – USB) Auto Trigger Phoenix Contact 20020007-G021B01LF (included in kit) Cycler Base Connector Auto Trigger Wiring Pin Number Excessive load on this pin will result in damage to the board. Critical Alarm A 0V to 3.3V transition will occur on the occurrence of a Critical fault Minor Alarm A 0V to 3.3V transition will occur on the occurrence of a Minor fault. A 3.3V to 0V transition will occur on the occurrence of any fault. System Ground – Isolated from chassis A low to high transistion of pin 6 will...
Open the catalog to page 6Smart Technology. Delivered. Controller LEDs Thermoelectric Controller Laird designs and manufactures customized, performance-critical products for wireless and other advanced electronics applications. The company is a global market leader in the design and supply of electromagnetic interference (EMI) shielding, thermal management products, signal integrity components, antenna solutions, as well as radio frequency (RF) modules and wireless remote controls a
Open the catalog to page 7Smart Technology. Delivered. Laird Technologies Thermoelectric Control File Help Tem|iei-l'!ie CM J Current CM | Cycle Current | Setup Maximums — Minimum; Time (Seconds] Cycle Count - Message Real Time Values Action Buttons Multiple Screen ACTION BUTTONS Green - Buttons that are currently active Blue - Buttons that can be made active if needed. Bright Red-STOP Dull Red - Already Stopped Gray - Mode is inhibiting the MULTIPLE SCREEN TABS Reference in next section. events while running. Both major and minor faults are noted in this window. Action Buttons The Start button is indicated by a...
Open the catalog to page 8Smart Technology. Delivered. TEMPERATURE CM (CYCLER MODULE TEMPERATURE] • The default tab shown above graphically plots the temperature profile per cycle. • Enabling the 'Min/Max Temp' feature from the setup tab will graphically record minimum and maximum temperatures measured by the cycler's RTD during cycling. • The RED horizontal line pairs are the three temperature setpoint margins. • Graph clears when cycling is restarted. CURRENT CM (CYCLER MODULE CURRENT] Laird Techno ogi-E: Them Real Time Values Temperature':.' = rle Current Setup - Maximums — Minimum! — DC Amps "ycle Count -...
Open the catalog to page 9Smart Technology. Delivered. CYCLER CURRENT - Laird Technologies Ther C Current Cycle Current Temperature CM | Current CM | Cycle Current] Setup |^ Serial Terminal Temp, Failure Seconds Temp. Failure Degrees Temp, Warning Seconds Negative Ramp Rate Temp, ".'Yarning Degre Temp Error Phase Cycle Current Phase Cycle Count - Message • The cycler current tab tracks the current at steady state per • The steady state level is set on the setup tab. • The green line is the running average ' Laird Technologies Thermoelei _Real Time Values_ C -:k Count DegreesC Current Cycle Current :xpc-:t.-:CM |...
Open the catalog to page 10Allows user to select serial port to control. The dropdown list will only show ports with the appropriate driver. Depressing this button will attempt to connect to selected COM port and will turn and remain green while active. Depressing this button again will release the serial port. Starting the COM port will also update the controller’s clock with system time and date. Reset Fault Allows the user to acknowledge a fault and clear the minor or major alarm. Triggered Mode Selecting this box will turn over start and end controls over to external digital control. Refer to auto trigger wiring....
Open the catalog to page 11Temp Error Phase This allows the operator to select which temperature phases will cause the above warnings or failure alerts. Temp warnings and failures do not apply during ramps. First Setpoint First temperature phase setpoint in degrees C with 0.1 degee resolution. Range is 0 to 150 degrees C in 0.1 degree increments. First Dwell Time in seconds for the controller to hold the first phase setpoint in 0.1 second increments. Range is 0 to 100 seconds in 0.1 second increments. Second Setpoint Second temperature phase setpoint in degrees C with 0.1 degee resolution. Range is 0 to 150 degrees C...
Open the catalog to page 12All LAIRD TECHNOLOGIES catalogs and technical brochures
-
Board Level Shields Catalog
26 Pages
-
EMI-CAT-Essentials 1213
117 Pages
-
THR-UM-AA-230
8 Pages
-
THR-BRO-Thermal
19 Pages
-
YS3805
1 Pages
-
YF45018
2 Pages
-
YF880012
2 Pages
-
YF88008
2 Pages
-
YF450112
2 Pages
-
ANT-DS-POE-xxi 0612
2 Pages
-
ANT-DS-POE-XXS-AFI 0712
2 Pages
-
LWS-BRO-Devices 1212
6 Pages
-
IAS-DS-External GPS 0115
2 Pages
-
LWS-LC-ASSET-TRACKING 0310
1 Pages
-
TEL-DS-Internal GPS 0310
2 Pages
-
THR-DS-TC-NTC-2 0413
2 Pages
-
THR-DS-GAPFILLER 0710
2 Pages
-
LT-THR-THIN FILM THERMOELEC 1212
20 Pages
-
THR-DS-UT9,28,F2,4040
2 Pages
-
Laird_Thermoelectric_Module
8 Pages
-
THR-BRO-LCS-012515
6 Pages
-
Power-Over-Ethernet
2 Pages
-
SIAMnet
12 Pages
-
Directional yagi antennas
1 Pages
-
BL620 Series
2 Pages
-
Multi-band Survivor ?
2 Pages
-
Liquid Cooling Systems
6 Pages
-
Ferrite EMI Noise Filtering
8 Pages
-
EMI CATALOG
116 Pages
-
Board Level Shields and Contacts
26 Pages
-
AC4486 - 868MHz Radio Module
3 Pages
-
Client Side Antennas
2 Pages
-
RFID Antennas
18 Pages
-
Ferrite EMI Cable Cores
24 Pages
-
WLAN Antennas
44 Pages
-
GPS/Telematics
8 Pages
-
Thermal Management Solutions
96 Pages
-
Knitted Conductive EMI Gasket
36 Pages
-
EMI ESSENTIALS
36 Pages
Archived catalogs
-
ZB2430 Wireless Modules
3 Pages
-
EMI Capabilities
13 Pages