PREMIUM EFFICIENCY THREE-PHASE MOTORS

Open the catalog to page 1
IE3 Range 2016 - 2

Premium Efficiency Motors High Efficiency Motors EISA Directive UL Environment Testing Method INTERNATIONAL EFFICIENCY LEVELS: IE CODES STANDARD FEATURES The International Standard IEC 60034-30-1;2014 ensures an • Very low temperature rise: allowing a service factor of 1.25, international common base for electric motor designing and extending insulation and bearings useful life classification, as well as for national legislative activities, increasing the level of harmonization in efficiency standard MEPS (Minimum Energy Performance Standard) all over the world. • Detachable feet to flange...

Open the catalog to page 2
IE3 Range 2016 - 3

SPECIAL EXECUTIONS TARGET APPLICATIONS A strong OEM orientation, with a wide range of special Solar Followers (Gear drive), Biogas & Biofuel Power Plant executions to offer the optimum electrical and mechanical (Cooling System) designs for particular markets or customer requests. • High reliability Excellent flexibility to specific market demands, the whole • High corrosion protection level (according to ISO 12944) manufacturing process is integrated within Lafert manufacturing • Special insulation system/voltage/frequency facilities, and that gives a high level of cost-efficiency. Lafert...

Open the catalog to page 3
IE3 Range 2016 - 4

PREMIUM EFFICIENCY THREE-PHASE MOTORS - IE3 ALLUMINIUM DESIGN EFFICIENCY LEVEL ACCORDING TO IEC 60034-30-1:2014 EFFICIENCY TESTING METHOD IEC 60034-2-1 ;2007 NOMINAL FULL LOAD EFFICIENCY ACCORDING TO IE3 CODE @ 400 V - 50 HZ TEMPERATURE RISE TO CLASS B

Open the catalog to page 4
IE3 Range 2016 - 5

PREMIUM EFFICIENCY THREE-PHASE MOTORS - IE3 CAST IRON DESIGN EFFICIENCY LEVEL ACCORDING TO IEC 60034-30-1:2014 EFFICIENCY TESTING METHOD IEC 60034-2-1;2007 NOMINAL FULL LOAD EFFICIENCY ACCORDING TO IE3 CODE @ 400 V - 50 HZ TEMPERATURE RISE TO CLASS B

Open the catalog to page 5
IE3 Range 2016 - 6

THREE-PHASE FRAME SIZE 80 - 160 IM B3 AMPE SERIES - ALUMINIUM ALLOY FRAME 2) Centering holes in shaft extensions to DIN 332 part 2

Open the catalog to page 6
IE3 Range 2016 - 7

THREE-PHASE frame size 180 - 315 im b3 ampe series - cast iron FRAME

Open the catalog to page 7
IE3 Range 2016 - 8

Branches & Partners Lafert GmbH Olgastraße 34/1 D - 73728 Esslingen - Germany Phone +49 / (0) 711 540 3095 + 7 Fax +49 / (0) 711 540 3098 lafert.germany@lafert.com Lafert Electric Motors Ltd. Unit 17 Orion Way Crewe, Cheshire CW1 6NG United Kingdom Phone +44 / (0) 1270 270 022 Fax +44 / (0) 1270 270 023 lafertuk@lafert.com Lafert Moteurs S.A.S. L’Isle d’Abeau Parc de Chesnes 75, rue de Malacombe F - 38070 St. Quentin-Fallavier France Phone +33 / 474 95 41 01 Fax +33 / 474 94 52 28 info.lafertmoteurs@lafert.com Lafert Motores Eléctricos, S.L. Polígono Pignatelli, Nave 27 E - 50410 Cuarte de...