1. Catalogs
  2. Labthink Instruments Co., Ltd.
  3. Test Packaging for Freshness: Preserving Cut Flowers During Transport-MAP test

Test Packaging for Freshness: Preserving Cut Flowers During Transport-MAP test

Test Packaging for Freshness: Preserving Cut Flowers During Transport-MAP test

Test Packaging for Freshness: Preserving Cut Flowers During Transport-MAP test

Product catalog summary
Overview: The C650H Headspace Gas Analyzer is designed for precise measurement of O2 and CO2 content in sealed packaging such as bags, bottles, and cans. It is suitable for use in production lines, warehouses, and laboratories.
Product Features:
  • Equipped with a high-precision ceramic oxygen sensor that offers good repeatability and a long service life.
  • Features a user-friendly PC material operation panel with an LCD display and supports both Chinese and English languages.
  • Includes a microcomputer control system for data analysis and report generation, with built-in data storage and an embedded micro printer for easy result printing.
  • Portable design with RS232 interface for computer connectivity and data management.
Testing Principle: The analyzer uses a vacuum pump to draw gas from the sample into the sensor, which then outputs real-time signals for O2 and CO2 concentrations. The instrument calculates these concentrations and records the results once the test is complete.
Test Applications:
  • Basic Applications: Suitable for testing O2 and CO2 content in non-negative pressure packaging such as pouches, bags, and various food and beverage containers.
  • Extended Applications: Applicable for testing head gas concentration in ampoule bottles.
Technical Parameters:
  • Gas Types: O2 (standard), CO2 (optional)
  • Measuring Range: O2 (0.2%–21%), CO2 (2%–100%)
  • Measurement Accuracy: O2 (±0.2%), CO2 (±2%)
  • Sample Size: ≥5ml for standard atmospheric pressure
  • Dimensions: 350mm x 330mm x 200mm
  • Power Supply: 220VAC 50Hz / 120VAC 60Hz
  • Net Weight: 5.5 kg
Product Configuration:
  • Standard: Mainframe, micro printer, sampling needle, filter, and gasket.
  • Optional: CO2 sensor, professional software, communication cable, hard packaging sampler, underwater sampling device.
Notes: The product specifications are subject to change for performance improvements. For the latest information, visit Labthink's website.
See more

Catalog excerpts

Test Packaging for Freshness: Preserving Cut Flowers During Transport-MAP test-1

C650H Headspace Gas Analyzer is of professional structure design and is with high-precision sensor, the O2 Content in sealed bags, bottles, cans and other hollow packaging containers can be accurately and conveniently determined. Meanwhile, with the selection of test accessories, CO2 can also be tested. It is suitable for the production line, warehouse, laboratory and other scenes to quickly and accurately evaluate the content of O2 and CO2 in the gas, so as to guide the production. • The new ceramic oxygen sensor developed by Labthink has the characteristics of high precision and good repeatability. • Ceramic oxygen sensor is non consumption type and has long service life. • PC material operation panel, menu interface, LCD display, easy to operate and view the results. • The system supports Chinese and English bilingual operating environment to meet the needs of different language users. • The microcomputer control system can analyze and process the test data and output the report. • It is easy to print the test results at any time with the embedded micro printer. • The system has built-in data storage to meet the needs of large amount of data storage. • Portable, easy to use in laboratory or production sites. • Equipped with RS232 interface and professional software, which convenient for computer connection and data import and export. Testing Principle The gas in the sample is pumped into the sensor through the vacuum pump, and the sensor outputs the real time current and voltage signals of O2 and CO2 (optional) concentration of the gas in the sample. The instrument calculates the content of O2 and CO2 (optional) in the gas by obtaining the current and voltage signal output by the sensor. After reaching the requirements for ending the tests, the tests stop, and the instrument records the concentration of O2 and CO2 (optional) in the gas tested in the sample. Test Applications Note 1 Basic It is suitable for the determination of O2 and CO2 (optional) content in Pouches/bags Applications non negative pressure pouches, packaging bags of coffee, cheese, milk Labthink Instruments Co., Ltd. 144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85062108 Labthink International, Inc. 200 River's Edge Drive, Medford, MA, 02155, U.S.A. Phone:+1-617-830-2190 FAX: +1-781-219-3638 www.labthink.com

 Open the catalog to page 1
Test Packaging for Freshness: Preserving Cut Flowers During Transport-MAP test-2

Packaging Containers Extended Applications Ampoule Bottles tea, milk powder, bread, soybean powder, modified atmosphere packaging, ready to eat food, medicine and other non negative pressure packaging bags. It is suitable for the determination of O2 and CO2 (optional) in canned coffee, canned milk powder, canned food, cheese, canned, Tetra Pak, beverage and other packaging containers It is suitable for testing the concentration of O2 and CO2 (optional) in the head gas of ampoules Technical Parameters Note 2 Items Type of Gas Measured Measuring Range Measurement Accuracy O2 (standard) 0.2%~21%...

 Open the catalog to page 2

All Labthink Instruments Co., Ltd. catalogs and technical brochures

  1. C610M

    3  Pages

  2. C690H

    4  Pages

  3. C130H

    4  Pages

  4. COF-P01

    2  Pages

  5. VAC-V2

    3  Pages

  6. C230H (2025)

    4  Pages

  7. C610H

    3  Pages

  8. C206H

    4  Pages

  9. C406H

    5  Pages

  10. C403H

    5  Pages

  11. C 681M

    1  Page

  12. C660B (2025)

    3  Pages

  13. C632M

    3  Pages

  14. C630H

    3  Pages

  15. C620H

    3  Pages

  16. C 640

    4  Pages

  17. C 660M

    3  Pages

  18. C306H (2025)

    4  Pages

  19. C203H

    4  Pages

  20. BTY-B3P

    2  Pages

  21. C360M

    4  Pages

  22. C632B

    3  Pages

  23. C190H

    3  Pages

  24. C390H

    4  Pages

  25. C360H

    4  Pages

  26. C660M

    3  Pages

  27. C303H

    4  Pages

  28. C106H

    5  Pages

  29. C640

    4  Pages

  30. MXD-02

    2  Pages

  31. CHY-C2A

    2  Pages

  32. C611B

    2  Pages

  33. CH130

    4  Pages

  34. C 631 H

    2  Pages

  35. C660 B

    3  Pages

  36. VAC-VBS

    3  Pages

  37. XYD-15K

    2  Pages

  38. C360

    4  Pages

  39. C631 H

    2  Pages

  40. FST-02

    2  Pages

  41. C681 M

    2  Pages

  42. C230

    4  Pages

  43. C631H

    2  Pages

  44. C612M

    3  Pages

  45. SLY-SI

    2  Pages

  46. C360 M

    4  Pages

  47. C611M

    2  Pages

  48. C330H

    4  Pages

  49. Leak Tester

    3  Pages

  50. Tensile Testers

    19  Pages

  51. FDI-01

    5  Pages

  52. DIN 75201

    2  Pages

  53. Abrasion Test

    2  Pages

  54. Torque Meter

    2  Pages

  55. Leak Detector

    2  Pages

  56. Torque tester

    2  Pages

  57. Impact tester

    2  Pages

  58. Gas Analyzer

    2  Pages

  59. TOQUE TESTER

    1  Page

Archived catalogs

  1. C611M

    2  Pages

  2. C306H

    3  Pages

  3. C230H

    4  Pages

  4. Leak Tester

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.