Cartella_Egon_korr.indd table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:11.00pt "Arial", sans-serif; } .font4 { font:12.00pt "Arial", sans-serif; } .font5 { font:30.00pt "Impact", sans-serif; } nrn.,r. ,w«^ -r n... Lsbthink PERME OX2/230 Oxygen Transmission Rate test system PERME OX2/230 Oxygen Transmission Rate Test System is applicable in the oxygen transmission rate testing of plastic films, high barrer materials, solar energy backsheets, sheets, laminated materials, aluminizer, coextrusion and foils as well as bottles, pouches, jars and boxes made of plastic, rubber, paper, glass and metal materials. Characteristics: Computer control; 3 Testing chambers integrated in one block (patent); 3 independent testing chambers in one; 1 master base can connect 9 satellite modules; thirty specimens testable simultaneously; Oxygen and water vapor transmission rate mixed testing control; Multi-testing modes: proportional, non-proportional, cycle and manual; Testing data can be stored in doc, database and Excel formats; Previous data inquiry, comparison and printing; original data re-analysis; 2 testing functions of film/sheet and finished package (optional purchase); Constant temperature and humidity control; Temperature and humidity testing port; Double side humidification of specimen; Pressure balance compensation; Catalytic deoxidization device; 2 carrier gas choice of high pure nitrogen and nitrogen with hydrogen; Broad power input; Rapid calibration with reference film; Network transmission interface for LAN data management and Internet data transmission. Principle Mount the pre-conditioned specimen between the upper and lower testing chambers. Oxygen or air flows in one side of specimen, high pure nitrogen flows in another side of the specimen. Oxygen molecules permeate through the specimen and enter into the high pure nitrogen side, which is then carried to the sensor by the flowing nitrogen. Obtain the oxygen transmission rate by analyzing the oxygen condensation detected by the sensor. For package test, high pure nitrogen flows in the package; air or pure oxygen flows around the outer side of the package. Technical Indexes: ® Film Testing Technical Indexes: Test Range:0.01 ~6500cm3/m2-day(Routine) 0.07~65000cm3/m2-day (Optional) Resolution: 0.001 ml/m2-day No. of specimens: 3 pieces (independent data respectively) Expansion Capability: 9 satellite modules (1-30 specimens) Specimen Size: 108mmx108mm Specimen Thickness: s3mm Test Area: 50cm2 Temp. Control Range: 15°C~55°C(Routine) Labthink instruments Co., ltd. No. 144 Wuyingshan Road, Jinan 250031, China. www.labthlnk.cn Tel : 0086 531-85024157 Fax : 0086 531-85812140

Open the catalog to page 1
Oxygen Permeability Tester - 2

Cartella_Egon_korr.indd table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } Temp. Control Accuracy: ±0.1_ (Routine) Humidity Control Range: 0%RH; 35%RH~90%RH; 100%RH Humidity Control Accuracy: ±1%RH Test gas: oxygen, air, etc. (Users provide gas sources for themselves) Gas Source Pressure: 0.28MPa, 40.6psi Inlet Size: 1/8 inch metal pipe Carrier Gas: 99.999% high pure nitrogen, or nitrogen with 2% hydrogen (Users provide gas sources for themselves) Dimensions: 690mm (L)x350mm (B)*360 mm(H)...

Open the catalog to page 2

All Labthink Instruments Co. catalogs and technical brochures

  1. DIN 75201

    2 Pages

  2. Torque Meter

    2 Pages

  3. Gas Analyzer

    2 Pages

  4. TOQUE TESTER

    1 Pages

Archived catalogs

  1. Leak Tester

    2 Pages