Oxygen Permeability Tester
1 / 2Pages

Catalog excerpts

Oxygen Permeability Tester - 1

Cartella_Egon_korr.indd table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:8.00pt "Arial", sans-serif; } .font3 { font:11.00pt "Arial", sans-serif; } .font4 { font:12.00pt "Arial", sans-serif; } .font5 { font:30.00pt "Impact", sans-serif; } nrn.,r. ,w«^ -r n... Lsbthink PERME OX2/230 Oxygen Transmission Rate test system PERME OX2/230 Oxygen Transmission Rate Test System is applicable in the oxygen transmission rate testing of plastic films, high barrer materials, solar energy backsheets, sheets, laminated materials, aluminizer, coextrusion and foils as well as bottles, pouches, jars and boxes made of plastic, rubber, paper, glass and metal materials. Characteristics: Computer control; 3 Testing chambers integrated in one block (patent); 3 independent testing chambers in one; 1 master base can connect 9 satellite modules; thirty specimens testable simultaneously; Oxygen and water vapor transmission rate mixed testing control; Multi-testing modes: proportional, non-proportional, cycle and manual; Testing data can be stored in doc, database and Excel formats; Previous data inquiry, comparison and printing; original data re-analysis; 2 testing functions of film/sheet and finished package (optional purchase); Constant temperature and humidity control; Temperature and humidity testing port; Double side humidification of specimen; Pressure balance compensation; Catalytic deoxidization device; 2 carrier gas choice of high pure nitrogen and nitrogen with hydrogen; Broad power input; Rapid calibration with reference film; Network transmission interface for LAN data management and Internet data transmission. Principle Mount the pre-conditioned specimen between the upper and lower testing chambers. Oxygen or air flows in one side of specimen, high pure nitrogen flows in another side of the specimen. Oxygen molecules permeate through the specimen and enter into the high pure nitrogen side, which is then carried to the sensor by the flowing nitrogen. Obtain the oxygen transmission rate by analyzing the oxygen condensation detected by the sensor. For package test, high pure nitrogen flows in the package; air or pure oxygen flows around the outer side of the package. Technical Indexes: ® Film Testing Technical Indexes: Test Range:0.01 ~6500cm3/m2-day(Routine) 0.07~65000cm3/m2-day (Optional) Resolution: 0.001 ml/m2-day No. of specimens: 3 pieces (independent data respectively) Expansion Capability: 9 satellite modules (1-30 specimens) Specimen Size: 108mmx108mm Specimen Thickness: s3mm Test Area: 50cm2 Temp. Control Range: 15°C~55°C(Routine) Labthink instruments Co., ltd. No. 144 Wuyingshan Road, Jinan 250031, China. www.labthlnk.cn Tel : 0086 531-85024157 Fax : 0086 531-85812140

Open the catalog to page 1
Oxygen Permeability Tester - 2

Cartella_Egon_korr.indd table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } Temp. Control Accuracy: ±0.1_ (Routine) Humidity Control Range: 0%RH; 35%RH~90%RH; 100%RH Humidity Control Accuracy: ±1%RH Test gas: oxygen, air, etc. (Users provide gas sources for themselves) Gas Source Pressure: 0.28MPa, 40.6psi Inlet Size: 1/8 inch metal pipe Carrier Gas: 99.999% high pure nitrogen, or nitrogen with 2% hydrogen (Users provide gas sources for themselves) Dimensions: 690mm (L)x350mm (B)*360 mm(H)...

Open the catalog to page 2

All Labthink Instruments Co. catalogs and technical brochures

  1. C610M

    3 Pages

  2. C690H

    4 Pages

  3. C130H

    4 Pages

  4. COF-P01

    2 Pages

  5. VAC-V2

    3 Pages

  6. C230H

    4 Pages

  7. C610H

    3 Pages

  8. C206H

    4 Pages

  9. C406H

    5 Pages

  10. C403H

    5 Pages

  11. C 681M

    1 Pages

  12. C660B

    3 Pages

  13. C632M

    3 Pages

  14. C630H

    3 Pages

  15. C620H

    3 Pages

  16. C 640

    4 Pages

  17. C 660M

    3 Pages

  18. C306H

    3 Pages

  19. C306H

    4 Pages

  20. C203H

    4 Pages

  21. BTY-B3P

    2 Pages

  22. C360M

    4 Pages

  23. C230H

    4 Pages

  24. C611M

    2 Pages

  25. C632B

    3 Pages

  26. C190H

    3 Pages

  27. C640

    4 Pages

  28. C660M

    3 Pages

  29. C106H

    5 Pages

  30. C303H

    4 Pages

  31. C360H

    4 Pages

  32. MXD-02

    2 Pages

  33. C390H

    4 Pages

  34. CHY-C2A

    2 Pages

  35. CHY-C2A

    2 Pages

  36. C130H

    4 Pages

  37. C611B

    2 Pages

  38. BTY-B3P

    2 Pages

  39. CH130

    4 Pages

  40. C632B

    3 Pages

  41. C 631 H

    2 Pages

  42. C660 B

    3 Pages

  43. VAC-VBS

    3 Pages

  44. XYD-15K

    2 Pages

  45. C360

    4 Pages

  46. C631 H

    2 Pages

  47. FST-02

    2 Pages

  48. C681 M

    2 Pages

  49. C230

    4 Pages

  50. C631H

    2 Pages

  51. C612M

    3 Pages

  52. C620H

    3 Pages

  53. SLY-SI

    2 Pages

  54. C360 M

    4 Pages

  55. C611M

    2 Pages

  56. C330H

    4 Pages

  57. FDI-01

    5 Pages

  58. DIN 75201

    2 Pages

  59. Torque Meter

    2 Pages

  60. Gas Analyzer

    2 Pages

  61. TOQUE TESTER

    1 Pages

Archived catalogs

  1. Leak Tester

    2 Pages