1. Catalogs
  2. Labthink Instruments Co., Ltd.
  3. Optimizing Shelf Life Prediction with Headspace Gas Analysis

Optimizing Shelf Life Prediction with Headspace Gas Analysis
1 /2Pages

Optimizing Shelf Life Prediction with Headspace Gas Analysis

Optimizing Shelf Life Prediction with Headspace Gas Analysis
1 /2Pages

Catalog excerpts

Optimizing Shelf Life Prediction with Headspace Gas Analysis-1

C650H Headspace Gas Analyzer is of professional structure design and is with high-precision sensor, the O2 Content in sealed bags, bottles, cans and other hollow packaging containers can be accurately and conveniently determined. Meanwhile, with the selection of test accessories, CO2 can also be tested. It is suitable for the production line, warehouse, laboratory and other scenes to quickly and accurately evaluate the content of O2 and CO2 in the gas, so as to guide the production. The new ceramic oxygen sensor developed by Labthink has the characteristics of high precision and good repeatability. Ceramic oxygen sensor is non consumption type and has long service life. PC material operation panel, menu interface, LCD display, easy to operate and view the results. The system supports Chinese and English bilingual operating environment to meet the needs of different language users. The microcomputer control system can analyze and process the test data and output the report. It is easy to print the test results at any time with the embedded micro printer. The system has built-in data storage to meet the needs of large amount of data storage. Portable, easy to use in laboratory or production sites. Equipped with RS232 interface and professional software, which convenient for computer connection and data import and export. Testing Principle The gas in the sample is pumped into the sensor through the vacuum pump, and the sensor outputs the real time current and voltage signals of O2 and CO2 (optional) concentration of the gas in the sample. The instrument calculates the content of O2 and CO2 (optional) in the gas by obtaining the current and voltage signal output by the sensor. After reaching the requirements for ending the tests, the tests stop, and the instrument records the concentration of O2 and CO2 (optional) in the gas tested in the sample. Test Applications Note 1 Basic Applications It is suitable for the determination of O2 and CO2 (optional) content in non negative pressure pouches, packaging bags of coffe

 Open the catalog to page 1
Optimizing Shelf Life Prediction with Headspace Gas Analysis-2

tea, milk powder, bread, soybean powder, modified atmosphere packaging, ready to eat food, medicine and other non negative pressure packaging bags. Extended Applications Packaging Containers It is suitable for the determination of O2 and CO2 (optional) in canned coffee, canned milk powder, canned food, cheese, canned, Tetra Pak, beverage and other packaging containers Ampoule Bottles It is suitable for testing the concentration of O2 and CO2 (optional) in the head gas of ampoules Technical Parameters Note 2 Items Measuring Range Measurement Accuracy Sample Size ≥ 5ml (standard atmospheric pressure)...

 Open the catalog to page 2

All Labthink Instruments Co., Ltd. catalogs and technical brochures

  1. C610M

    3  Pages

  2. C690H

    4  Pages

  3. C130H

    4  Pages

  4. COF-P01

    2  Pages

  5. VAC-V2

    3  Pages

  6. C230H (2025)

    4  Pages

  7. C610H

    3  Pages

  8. C206H

    4  Pages

  9. C406H

    5  Pages

  10. C403H

    5  Pages

  11. C 681M

    1  Page

  12. C660B (2025)

    3  Pages

  13. C632M

    3  Pages

  14. C630H

    3  Pages

  15. C620H

    3  Pages

  16. C 640

    4  Pages

  17. C 660M

    3  Pages

  18. C306H (2025)

    4  Pages

  19. C203H

    4  Pages

  20. BTY-B3P

    2  Pages

  21. C360M

    4  Pages

  22. C632B

    3  Pages

  23. C190H

    3  Pages

  24. C390H

    4  Pages

  25. C360H

    4  Pages

  26. C660M

    3  Pages

  27. C303H

    4  Pages

  28. C106H

    5  Pages

  29. C640

    4  Pages

  30. MXD-02

    2  Pages

  31. CHY-C2A

    2  Pages

  32. C611B

    2  Pages

  33. CH130

    4  Pages

  34. C 631 H

    2  Pages

  35. C660 B

    3  Pages

  36. VAC-VBS

    3  Pages

  37. XYD-15K

    2  Pages

  38. C360

    4  Pages

  39. C631 H

    2  Pages

  40. FST-02

    2  Pages

  41. C681 M

    2  Pages

  42. C230

    4  Pages

  43. C631H

    2  Pages

  44. C612M

    3  Pages

  45. SLY-SI

    2  Pages

  46. C360 M

    4  Pages

  47. C611M

    2  Pages

  48. C330H

    4  Pages

  49. Leak Tester

    3  Pages

  50. Tensile Testers

    19  Pages

  51. FDI-01

    5  Pages

  52. DIN 75201

    2  Pages

  53. Abrasion Test

    2  Pages

  54. Torque Meter

    2  Pages

  55. Leak Detector

    2  Pages

  56. Torque tester

    2  Pages

  57. Impact tester

    2  Pages

  58. Gas Analyzer

    2  Pages

  59. TOQUE TESTER

    1  Page

Archived catalogs

  1. C611M

    2  Pages

  2. C306H

    3  Pages

  3. C230H

    4  Pages

  4. Leak Tester

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.