1. Catalogs
  2. Labthink Instruments Co., Ltd.
  3. Non-destructive Leak Tester with vacuum decay method

Non-destructive Leak Tester with vacuum decay method

Non-destructive Leak Tester with vacuum decay method

Non-destructive Leak Tester with vacuum decay method

Product catalog summary
Overview: The C690M Non-destructive Package Leakage Detector is designed for detecting trace leakage in pharmaceutical packaging using vacuum and pressure methods, adhering to ASTM F2338 and other standards.
Features:
  • Multi-stage Vacuum: Utilizes both vacuum and positive pressure to address hole plugging issues. Features automatic clamping and fast switching technology for flexibility and reliability. The vacuum degree is adjustable, and the test cell is transparent for easy observation. An optional oil-free vacuum pump is available.
  • Precise Data: Employs advanced pressure detection and micro flow control technologies for accurate simulation of leakage holes. Data is traceable to NIST, with high test repetition accuracy.
  • Intelligent Control: Equipped with a 12.1" touch tablet running Windows OS, displaying real-time pressure curves and automatically calculating leakage amounts. Supports external data access and remote upgrades.
  • Security Compliance: Meets GMP requirements for data traceability and 21 CFR Part11 for electronic signatures. User permissions are configurable.
Test Principle: The sample is sealed in a test cell, vacuumized, and pressure changes are analyzed to calculate leakage rates.
Reference Standards: ASTM F2338, YY-T 0681.18, USP<1207>
Applications:
  • Basic Applications: Vial sealing tests.
  • Extended Applications: Ampoule, cartridge, and injection bottle sealing tests.
Technical Parameters:
  • Test Range: 2 to 8 um, with a detection lower limit of ≤2 um.
  • Resolution: 0.1 um, with repetitiveness of ±1 um.
  • Pressure Range: -100 to +100 kPa.
  • Sample Size: ≤Φ45 mm×80mm, customizable for larger samples.
  • Power: 120VAC±10% 60Hz / 220VAC±10% 50Hz.
Product Configuration:
  • Standard Configuration: Includes mainframe, tablet computer, software, flow meter, vacuum pump, and polyurethane tube.
  • Customization: Test cells and reference samples can be customized.
  • Optional Parts: GMP computer system, 21 CFR Part11 compliance, air compressor, and European vacuum pump.
See more

Catalog excerpts

Non-destructive Leak Tester with vacuum decay method-1

C690M Non-destructive Package Leakage Detector C690M Non-destructive Package Leakage Detector is based on the testing principles of vacuum method and pressure method, and is designed and manufactured according to ASTM F2338 and other standards. It is professionally suitable for the trace leakage detection of various drug packaging such as vials, ampoule bottles, cartridge bottles, infusion bottle, and prefilled needle and so on. Features Note 1 Multi-stage Vacuum  Dual methods of vacuum and positive pressure effectively solve the problem of hole plugging. Test cell adopts swing arm automatic clamping and fast switching technology, which is flexible and reliable. The target vacuum degree is set freely to meet detection requirements of different samples. Transparent test cell for easy observation of the sample state. Built-in European oil-free vacuum pump, which is maintenance-free and pollution-free (optional). International advanced pressure detection technology with stable data. International advanced micro flow automatic control technology that can accurately simulate different sizes of leakage holes without manual adjustment. Both the pressure and flow data are traceable to NIST. The system can achieve a higher test repetition of ±1um. 12.1" embedded touch tablet computer with Windows OS. The pressure curve is displayed in real time, and the test results are counted automatically. The leakage amount is calculated automatically. Universal printer can be connected for test results output. The system is embedded with USB and network port to facilitate th

 Open the catalog to page 1
Non-destructive Leak Tester with vacuum decay method-2

transmission of the system, and can be upgraded remotely. Verified by professional packaging sealing method. The detector meets the GMP requirements for data traceability and meets the needs of the pharmaceutical industry. User operation permission is managed at multiple levels, and the permission content can be configured on demand. Electronic signature is designed according to the standard requirements of 21 CFR Part11. Test Principle The sample is sealed in the test cell, and the sealed test cell is vacuumized. By analyzing the pressure change measured by the sensor, the leakage rate of the...

 Open the catalog to page 2
Non-destructive Leak Tester with vacuum decay method-3

Pressure Range GMP computer system requirements Extended Functions Table 2: Technical Specifications Test Cell Sample Size Sample Quantity Compressed air (Air source is provided by the user) Port Size Table 3: Product Configuration Standard Configuration Mainframe, embedded tablet computer, software, flow meter, vacuum pump, Φ6 mm polyurethane tube Test cell, negative standard reference sample and positive standard reference sample are designed according to the sample specifications Optional Parts GMP computer system requirements, 21 CFR Part11, air compressor, built-in European vacuum pump Note...

 Open the catalog to page 3

All Labthink Instruments Co., Ltd. catalogs and technical brochures

  1. C610M

    3  Pages

  2. C690H

    4  Pages

  3. C130H

    4  Pages

  4. COF-P01

    2  Pages

  5. VAC-V2

    3  Pages

  6. C230H (2025)

    4  Pages

  7. C610H

    3  Pages

  8. C206H

    4  Pages

  9. C406H

    5  Pages

  10. C403H

    5  Pages

  11. C 681M

    1  Page

  12. C660B (2025)

    3  Pages

  13. C632M

    3  Pages

  14. C630H

    3  Pages

  15. C620H

    3  Pages

  16. C 640

    4  Pages

  17. C 660M

    3  Pages

  18. C306H (2025)

    4  Pages

  19. C203H

    4  Pages

  20. BTY-B3P

    2  Pages

  21. C360M

    4  Pages

  22. C632B

    3  Pages

  23. C190H

    3  Pages

  24. C390H

    4  Pages

  25. C360H

    4  Pages

  26. C660M

    3  Pages

  27. C303H

    4  Pages

  28. C106H

    5  Pages

  29. C640

    4  Pages

  30. MXD-02

    2  Pages

  31. CHY-C2A

    2  Pages

  32. C611B

    2  Pages

  33. CH130

    4  Pages

  34. C 631 H

    2  Pages

  35. C660 B

    3  Pages

  36. VAC-VBS

    3  Pages

  37. XYD-15K

    2  Pages

  38. C360

    4  Pages

  39. C631 H

    2  Pages

  40. FST-02

    2  Pages

  41. C681 M

    2  Pages

  42. C230

    4  Pages

  43. C631H

    2  Pages

  44. C612M

    3  Pages

  45. SLY-SI

    2  Pages

  46. C360 M

    4  Pages

  47. C611M

    2  Pages

  48. C330H

    4  Pages

  49. Leak Tester

    3  Pages

  50. Tensile Testers

    19  Pages

  51. FDI-01

    5  Pages

  52. DIN 75201

    2  Pages

  53. Abrasion Test

    2  Pages

  54. Torque Meter

    2  Pages

  55. Leak Detector

    2  Pages

  56. Torque tester

    2  Pages

  57. Impact tester

    2  Pages

  58. Gas Analyzer

    2  Pages

  59. TOQUE TESTER

    1  Page

Archived catalogs

  1. C611M

    2  Pages

  2. C306H

    3  Pages

  3. C230H

    4  Pages

  4. Leak Tester

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.