Oxygen Transmission Rate Test System Overview
The i-Oxtra 7700 Oxygen Transmission Rate Test System utilizes the coulometric method for measuring oxygen transmission rates. It features a three-in-one diffusion cell structure and can use either high-purity nitrogen or hydrogen-mixed nitrogen as carrier gases. The system is equipped with palladium catalysts for carrier gas purification, enhancing the accuracy of results.
Key Benefits
  • Increased sample throughput.
  • Flexible carrier gas selection.
  • Enhanced purity of nitrogen for high accuracy in OTR results.
Specifications
  • Test Range: 0.01~6500 cm3/m2·d (standard), 0.07~65,000 cm3/m2·d (optional), 0.0001~60 cm3/pkg·d.
  • Number of Specimens: 1~3 with independent test results.
  • Resolution: 0.001 cm3/m2·d, 0.00001 cm3/pkg·d.
  • Temperature Range: 15°C~55°C with an accuracy of ±0.1°C.
  • Humidity Range: 0%RH, 35%RH~90%RH, 100%RH with an accuracy of ±1%RH.
  • Test Gas: Oxygen and air (not supplied).
  • Specimen Thickness: ≤3 mm (customizable for other thicknesses).
  • Test Area: 50 cm2.
  • Specimen Size: 108 mm x 108 mm, with specific size limitations for tests with temperature control devices.
  • Carrier Gas: 99.999% high purity nitrogen or nitrogen with 2% hydrogen (not supplied).
  • Carrier Gas Pressure: ≥ 0.28 MPa.
  • Port Size: 1/8 inch copper tubing.
  • Instrument Dimension: 690 mm (L) x 350 mm (W) x 360 mm (H).
  • Power Supply: AC (85~264)V (47~63)Hz.
  • Net Weight: 70 kg.
Related Product
i-Oxtra 7600 Oxygen Transmission Rate Test System.
See more

Catalog excerpts

Labthink Oxygen transmission rate test system i-Oxtra 7700 for flims and sheets-1

Oxygen transition rate test system

 Open the catalog to page 1
Labthink Oxygen transmission rate test system i-Oxtra 7700 for flims and sheets-2

Email: trade5(3)labthink.cnPhone:086-531-85068566 Website.- www.labthink.com i-Oxtra 7700 Oxygen Transmission Rate Test System Coulometric Method > Three-in-one diffusion cell structure > Both high-purity nitrogen and hydrogen-mixed nitrogen can be used as > Equipped with palladium catalysts for carrier gas purification > Increase sample throughput > Flexible selection of carrier gas > Increase purity of nitrogen and obtain high accuracy of OTR results Email: trade5(5)labthink.cnPhone:086-531-85068566 Website.- www.labthink.com

 Open the catalog to page 2
Labthink Oxygen transmission rate test system i-Oxtra 7700 for flims and sheets-3

Specifications Film Test Package Test (customization available) 1~3 with independent test results Specimens Resolution Range Temperature Accuracy Humidity Range Humidity Oxygen and air (outside of supply scope) available for other thickness) Test Area One package with temperature control device: specimen should be smaller than Ф150 mm and lower than 380 mm Specimen Size Three packages with temperature control device: specimens should be smaller than Ф100 mm, and lower than 380 mm No size limitation for tests without temperature control device

 Open the catalog to page 3
Labthink Oxygen transmission rate test system i-Oxtra 7700 for flims and sheets-4

Email: [email protected]:086-531-85068566 Website.- www.labthink.com Carrier Gas 99.999% high purity nitrogen or nitrogen with 2% hydrogen (outside of supply scope) Port Size 1/8 inch copper tubing Related Product: -Oxtra 7600 Oxygen Transmission Rate Email: trade5(a)labthink.cnPhone:086-531-85068566 Website.- www.labthink.com

 Open the catalog to page 4

All Labthink Instruments Co., Ltd. catalogs and technical brochures

  1. C610M

    3  Pages

  2. C690H

    4  Pages

  3. C130H

    4  Pages

  4. COF-P01

    2  Pages

  5. VAC-V2

    3  Pages

  6. C230H (2025)

    4  Pages

  7. C610H

    3  Pages

  8. C206H

    4  Pages

  9. C406H

    5  Pages

  10. C403H

    5  Pages

  11. C 681M

    1  Page

  12. C660B (2025)

    3  Pages

  13. C632M

    3  Pages

  14. C630H

    3  Pages

  15. C620H

    3  Pages

  16. C 640

    4  Pages

  17. C 660M

    3  Pages

  18. C306H (2025)

    4  Pages

  19. C203H

    4  Pages

  20. BTY-B3P

    2  Pages

  21. C360M

    4  Pages

  22. C632B

    3  Pages

  23. C190H

    3  Pages

  24. C390H

    4  Pages

  25. C360H

    4  Pages

  26. C660M

    3  Pages

  27. C303H

    4  Pages

  28. C106H

    5  Pages

  29. C640

    4  Pages

  30. MXD-02

    2  Pages

  31. CHY-C2A

    2  Pages

  32. C611B

    2  Pages

  33. CH130

    4  Pages

  34. C 631 H

    2  Pages

  35. C660 B

    3  Pages

  36. VAC-VBS

    3  Pages

  37. XYD-15K

    2  Pages

  38. C360

    4  Pages

  39. C631 H

    2  Pages

  40. FST-02

    2  Pages

  41. C681 M

    2  Pages

  42. C230

    4  Pages

  43. C631H

    2  Pages

  44. C612M

    3  Pages

  45. SLY-SI

    2  Pages

  46. C360 M

    4  Pages

  47. C611M

    2  Pages

  48. C330H

    4  Pages

  49. Leak Tester

    3  Pages

  50. Tensile Testers

    19  Pages

  51. FDI-01

    5  Pages

  52. DIN 75201

    2  Pages

  53. Abrasion Test

    2  Pages

  54. Torque Meter

    2  Pages

  55. Leak Detector

    2  Pages

  56. Torque tester

    2  Pages

  57. Impact tester

    2  Pages

  58. Gas Analyzer

    2  Pages

  59. TOQUE TESTER

    1  Page

Archived catalogs

  1. C611M

    2  Pages

  2. C306H

    3  Pages

  3. C230H

    4  Pages

  4. Leak Tester

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.