Product catalog summary
Scope
The i-OXTRA 7700 Oxygen Transmission Rate Testing System is designed to measure the oxygen transmission rate of various materials including plastic films, composite films, sheets, high barrier materials, solar back sheets, aluminum foils, aluminized films, coextruded films, and containers made from plastics, rubber, glass, paper, and metals.
Test Procedures
  • Preparation: Clean the package test plate with ethanol and secure the specimen using Araldite Rapid Transparent adhesive. Allow 60 minutes for the adhesive to solidify.
  • Mounting: Attach the specimen to the inner test chamber and secure with screws.
  • Sealing: Cover the specimen with a plastic bag, ensuring proper sealing with adhesives. Oxygen is introduced through the chamber, and exhaust is managed via the plastic bag outlet.
  • Connection Check: Ensure tubing connections are secure, set the stop valve to "ON," and adjust the pressure to 0.15 MPa.
  • Parameter Setup: Select "Package" as the specimen type and initiate the test.
  • Flow Observation: Monitor the flow rates, ensuring Cell A, B, C, and Zero maintain 10±1 ml/min, and oxygen flow is 60±10 ml/min. Adjust flows using the valves as needed.
  • Results: Review test results and reports. Repeat the procedure if necessary.
See more

Catalog excerpts

i-OXTRA 7700 Oxygen Transmission Rate Testing System ---Package Test-1

i-OXTRA 7700 Oxygen Transmission Rate Testing System ---Package Test Scope i-OXTRA 7700 Oxygen Transmission Rate Testing System is designed to determine the oxygen transmission rate of plastic films, composite films, sheets, high barrier materials, solar back sheets, aluminum foils, aluminized film, coextruded film and bottles, cans and boxes made of plastics, rubber, glass, paper and other metal materials. Test Procedures A: Remove the remaining adhesives on the surface of package test plate and clean it with ethanol cotton ball. Invert the package specimen and place it on the upper surface of the test plate with the gas inlet and outlet into the package. Fix the specimen on the surface of test plate with prepared Araldite Rapid Transparent adhesive. Wait for 60 minutes in room temperature until the adhesives become solidified.

 Open the catalog to page 1
i-OXTRA 7700 Oxygen Transmission Rate Testing System ---Package Test-2

B: Mount the package specimen on the integrated inner test chamber and fix the screws with spanner. C: Cover the package specimen with a plastic bag and tie the mouth of the plastic bag to the mouth of the package. Meanwhile oxygen is led into the plastic bag through the oxygen outlet of inner chamber and the exhaust oxygen would be released through the oxygen outlet of the plastic bag. Use adhesives to seal the space between PU tubing and the plastic bag and close the door of thermal container. If the test is performed under ambient temperature and humidity with air, it is no necessary to cover...

 Open the catalog to page 2
i-OXTRA 7700 Oxygen Transmission Rate Testing System ---Package Test-3

D: Check the tubing connection. Turn the stop valve to “ON” position and adjust the pressure regulator until the output pressure gauge indicates 0.15 MPa.

 Open the catalog to page 3
i-OXTRA 7700 Oxygen Transmission Rate Testing System ---Package Test-4

E: Set up test parameters. Select specimen type “Package” and start the test. F: Observe the flow of each test cell in process of testing. The flow of Cell A, B, C and Zero should be 10± ml/min and the 1 flow of oxygen should be 60± ml/min. Otherwise the flow should be adjusted by turning the valves in clockwise or 10 counterclockwise direction. Turn in clockwise direction to decrease the flow, while counterclockwise direction to increase the flow. The flow rate of oxygen would not be displayed in test interface. A rotameter should be inserted into the multi-port to check the flow rate of oxygen....

 Open the catalog to page 4
i-OXTRA 7700 Oxygen Transmission Rate Testing System ---Package Test-5

G: View the test results and reports. If necessary, repeat the above procedures to perform another round of tests.

 Open the catalog to page 5

All Labthink Instruments Co., Ltd. catalogs and technical brochures

  1. C610M

    3  Pages

  2. C690H

    4  Pages

  3. C130H

    4  Pages

  4. COF-P01

    2  Pages

  5. VAC-V2

    3  Pages

  6. C230H (2025)

    4  Pages

  7. C610H

    3  Pages

  8. C206H

    4  Pages

  9. C406H

    5  Pages

  10. C403H

    5  Pages

  11. C 681M

    1  Page

  12. C660B (2025)

    3  Pages

  13. C632M

    3  Pages

  14. C630H

    3  Pages

  15. C620H

    3  Pages

  16. C 640

    4  Pages

  17. C 660M

    3  Pages

  18. C306H (2025)

    4  Pages

  19. C203H

    4  Pages

  20. BTY-B3P

    2  Pages

  21. C360M

    4  Pages

  22. C632B

    3  Pages

  23. C190H

    3  Pages

  24. C390H

    4  Pages

  25. C360H

    4  Pages

  26. C660M

    3  Pages

  27. C303H

    4  Pages

  28. C106H

    5  Pages

  29. C640

    4  Pages

  30. MXD-02

    2  Pages

  31. CHY-C2A

    2  Pages

  32. C611B

    2  Pages

  33. CH130

    4  Pages

  34. C 631 H

    2  Pages

  35. C660 B

    3  Pages

  36. VAC-VBS

    3  Pages

  37. XYD-15K

    2  Pages

  38. C360

    4  Pages

  39. C631 H

    2  Pages

  40. FST-02

    2  Pages

  41. C681 M

    2  Pages

  42. C230

    4  Pages

  43. C631H

    2  Pages

  44. C612M

    3  Pages

  45. SLY-SI

    2  Pages

  46. C360 M

    4  Pages

  47. C611M

    2  Pages

  48. C330H

    4  Pages

  49. Leak Tester

    3  Pages

  50. Tensile Testers

    19  Pages

  51. FDI-01

    5  Pages

  52. DIN 75201

    2  Pages

  53. Abrasion Test

    2  Pages

  54. Torque Meter

    2  Pages

  55. Leak Detector

    2  Pages

  56. Torque tester

    2  Pages

  57. Impact tester

    2  Pages

  58. Gas Analyzer

    2  Pages

  59. TOQUE TESTER

    1  Page

Archived catalogs

  1. C611M

    2  Pages

  2. C306H

    3  Pages

  3. C230H

    4  Pages

  4. Leak Tester

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.