i-OXTRA 7700 Oxygen Transmission Rate Testing System ---Medical Blister Package Test
4Pages

{{requestButtons}}

Catalog excerpts

i-OXTRA 7700 Oxygen Transmission Rate Testing System ---Medical Blister Package Test - 1

i-OXTRA 7700 Oxygen Transmission Rate Testing System ---Medical Blister Package Test Scope i-OXTRA 7700 Oxygen Transmission Rate Testing System is designed to determine the oxygen transmission rate of plastic films, composite films, sheets, high barrier materials, solar back sheets, aluminum foils, aluminized film, coextruded film and bottles, cans and boxes made of plastics, rubber, glass, paper and other metal materials. Test Procedures A: Prepare the test specimen according to specific standard. Insert the pipe of nitrogen inlet and outlet into the medical blister package and connect them to the integrated inner test chamber. B: Enclose the package specimen in an aluminum foil cover and connect the pipe of oxygen inlet and outlet to the inside of the aluminum foil cover.

Open the catalog to page 1
i-OXTRA 7700 Oxygen Transmission Rate Testing System ---Medical Blister Package Test - 2

C: Tie the aluminum foil cover tightly and close the door of thermal container. D: Check the tubing connection. Turn the stop valve to “ON” position and adjust the pressure regulator until the output pressure gauge indicates 0.15 MPa.

Open the catalog to page 2
i-OXTRA 7700 Oxygen Transmission Rate Testing System ---Medical Blister Package Test - 3

E: Set up test parameters. Select specimen type “Package” and start the test. F: Observe the flow of each test cell in process of testing. The flow of Cell A, B, C and Zero should be 10± ml/min and the 1 flow of oxygen should be 60± ml/min. Otherwise the flow should be adjusted by turning the valves in clockwise or 10 counterclockwise direction. Turn in clockwise direction to decrease the flow, while counterclockwise direction to increase the flow. The flow rate of oxygen would not be displayed in test interface. A rotameter should be inserted into the multi-port to check the flow rate of...

Open the catalog to page 3
i-OXTRA 7700 Oxygen Transmission Rate Testing System ---Medical Blister Package Test - 4

G: View the test results and reports. If necessary, repeat the above procedures to perform another round of tests.

Open the catalog to page 4