i-Meditek 1300 Medical Packaging Tester ---Puncture Force Test of Rubber Closure - 1

i-Meditek 1300 Medical Packaging Tester ---Puncture Force Test of Rubber Closure Scope i-Meditek 1300 Medical Packaging Tester is designed to determine the puncture force of medical rubber closure, pullout force of rubber closure, break force of ampoule, sliding resistance of syringe, puncture force of syringe needle, connection force of syringe needle and needle hub, connection force of syringe needle hub and shield, seal performance of plastic blood bag, and the performance of other medical appliances. As well, i-Meditek 1300 could test the tensile strength, peeling force, heat seal strength, deformation, tearing force, adhesive performance, piercing force, opening force, low speed unwrapping force and pullout force etc. of plastic films, composite materials, flexible packaging materials, plastic soft tube, adhesives, adhesive tapes, protective films, combination caps, aluminum foils, diaphragms, back sheets, non-woven fabrics, rubber, release paper and other products. Test Procedures A: Prepare test specimens according to specific standards. Adjust the sample grips and mount the specimen. Prepare 10 rubber closures to be tested and another 10 rubber closures with already known puncture force and then mount the rubber closures to corresponding infusion bottles. Fix the infusion bottle with rubber closure in the device for puncture test. Wipe the needle with acetone and make sure the needle is sharp then install the needle in the device for puncture test so that the needle could puncture the rubber closures from the center of them.

Open the catalog to page 1
i-Meditek 1300 Medical Packaging Tester ---Puncture Force Test of Rubber Closure - 2

200 River's Edge Drive, Medford, MA 02155 Test Parameter ; [Specimen Parameter] j Result System Info Configuration Specimen name Specimen provider Type of Rubber Closures Stop Displacerrient(mm) Specimen material Specimen Manu. Inspection Orga. Syringe Needle OD(mrn) Click "Test" button nterface. If necessary, mount next specimen and click "Test" button. When all tests are finished, click "Generate Result". Test Parameter Specimen Parameter | [Result] System Info | Configuration Maximum(N) Minimum(N) Mean(fJ) Curve Type Force-Displacement Curve Analysis Generate Result Compare Results Print...

Open the catalog to page 2

All Labthink Instruments Co. catalogs and technical brochures

  1. DIN 75201

    2 Pages

  2. Torque Meter

    2 Pages

  3. Gas Analyzer

    2 Pages

  4. TOQUE TESTER

    1 Pages

Archived catalogs

  1. Leak Tester

    2 Pages