video corpo

Gas Permeability Tester
1Pages

{{requestButtons}}

Catalog excerpts

Gas Permeability Tester - 1

untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:8.00pt "Arial", sans-serif; } .font2 { font:11.00pt "Arial", sans-serif; } .font3 { font:19.00pt "Arial Black", sans-serif; } .font4 { font:32.50pt "Impact", sans-serif; } I o ht h in If PERME® VAC-V2 Gas Permeability Tester WPIIIHHI PERME VAC-V2 Gas Permeability Tester is applicable in the measurement of gas permeability rate, solubility coefficient, diffusion coefficient and permeability coefficient at various temperature of plastic films, laminated films, high barrier material, s heets, foils, and etc. Computer control, full automatic testing; Diffusion coefficient, solubility coefficient and permeability coefficient measurement. Two testing modes of proportional and non-proportional; Measure range extension block; 3 independent chambers; Constant temperature control; Optional humidity control; Data curvefitting function at any temperatures. Can be extended to cover the tests for poisonous and explosive gases; Rapid calibration with reference film; RS232 interface; Network transmission interface for LAN data management and Internet data transmission. Put the pre-conditioned specimen between the upper chamber and chamber, clamp it tightly. First vacuumize the low-pressure chamber (lower chamber), and then the whole system. When the specified degree of vacuum is achieved, shut off the lower test chamber and feed test gas to the upper test chamber (high pressure chamber) until certain pressure is reached. Ensure that a constant differential pressure (adjustable) is maintained across the specimen. Hence under the gradient of differential pressure the test gas permeates from the high-pressure side to the low-pressure side. By monitoring and measuring the pressure in the low-pressure side we can get various barrier parameters of the tested specimen. Technical Indexes Test Range: 0.05 ~ 50,000 cm3/m2-24h -0.1MPa (Routine) Upper limit is not less than 500,000 cm//m2«24h -0.1 MPa (extension volume) Note: Routine and extension volume can be selected using extension volume blocks.. Temp. Control Range: 5°C~95°C Temp. Control Accuracy: ±0.1°C Humidity Control Range: 0%RH, 2%RH~98.5%,100%RH (humidity generatorshould be purchased separately) Humidity Control Accuracy: ±1%RH Vacuum Resolution: 0.1Pa Vacuum Degree: <20Pa Specimen Size: 097mm No. of Specimens: 3 pieces (independent data respectively) Transmission Area: 38.48cm2 Test Gas: O2, N2 and CO2, etc.(Users provide gas source themselves) Test Pressure: -0.1MPa ~+0.1MPa Pressure of Gas Source: 0.4MPa~0.6MPa Inlet Size: 06mm polyurethane pipe Dimensions: 760mm (L)x575mm (B)x450mm (H) Power: AC 220V 50Hz Net weight: 88kg ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A, GB 1038,YBB 00082003 Configuration Standard : Mainframe, temperature controller, software, sample cutter, vacuum grease, vacuum pump, filter paper. Optional: blades, vacuum grease, oil for vacuum pump, filter paper ,humidity generator Note: Users provide test gas cylinder and distilled water for themselves. It is betterto use server instead ofthe common computer. O6mm PU pipe is equipped to connect the unit to gas resource Labthink instruments Co., Itd. No. 144 Wuyingshan Road, Jinan 250031, China. www.labthink.cn Tel : 0086 531-85824157 Fax : 0086 531 -85812140

Open the catalog to page 1

All Labthink Instruments Co. catalogs and technical brochures

  1. FDI-01

    5 Pages

  2. DIN 75201

    2 Pages

  3. Torque Meter

    2 Pages

  4. Gas Analyzer

    2 Pages

  5. TOQUE TESTER

    1 Pages

Archived catalogs

  1. Leak Tester

    2 Pages