1. Catalogs
  2. Labthink Instruments Co., Ltd.
  3. gas permeability tester for Organosilicone film

gas permeability tester for Organosilicone film

gas permeability tester for Organosilicone film

gas permeability tester for Organosilicone film

Product catalog summary
Abstract: This document discusses the testing method for gas permeability of organosilicon films using the differential pressure method. The focus is on measuring carbon dioxide transmission, providing a reference for testing other gas barrier properties.
Introduction: Organosilicon films are semi-inorganic and semi-organic polymers known for their heat resistance, flexibility, dielectric strength, and selective permeability. They are used in various fields such as electronics, packaging, and pharmaceuticals. Gas permeability is crucial for their application, influencing factors like wound healing and separation efficiency.
Test Sample: The study uses a specific type of organosilicon film to test carbon dioxide permeability.
Standard: The testing follows ISO 2556, which outlines the manometric method for determining gas transmission rates in films under atmospheric pressure.
Test Instrument: The VAC-V2 Differential Pressure Gas Permeability Tester from Jinan Labthink Instruments Co., Ltd. is used for the tests.
Test Principle: The differential pressure method measures gas transmission by monitoring pressure changes in a chamber divided into upper and lower sections. The gas penetrates the test sample, and pressure changes are recorded to calculate permeability.
Test Process: Three specimens are prepared, and vacuum grease is applied. The specimens are placed in the test chambers, and the equipment is connected to a carbon dioxide source. Parameters such as sample name, thickness, and test conditions are set in the control software. The test is initiated, and results are displayed post-test.
Test Results: The permeability results for the three samples were 2.671×105, 2.704×105, and 2.693×105 cm3/(m2·24h·0.1MPa), with an average of 2.689×105 cm3/(m2·24h·0.1MPa).
Conclusion: The study confirms that organosilicon films have high carbon dioxide permeability. The testing process is efficient, allowing multiple samples to be tested simultaneously. Jinan Labthink Instruments Co., Ltd. offers advanced testing solutions to enhance packaging quality and safety.
See more

Catalog excerpts

gas permeability tester for Organosilicone film-1

Test Method for Organosilicon Film Gas Permeability Abstract: Organosilicone film is a new type of polymer material with excellent performance. The gas permeability is an important factor affecting the application of organosilicone film. In this paper, the principle of differential pressure method is used to measure the carbon dioxide transmission of a kind of organosilicone film, and the test principle, equipment parameters, application scope, test process and other contents are introduced, which provides a reference for the test of other gas barrier properties of organosilicone film. Keywords: organosilicone film, carbon dioxide transmission rate, differential pressure gas permeability tester, permeability, differential pressure method Organosilicon film is a type of semi-inorganic and semi-organic polymer material. It has good heat resistance, low-temperature flexibility, high dielectric strength, chemical inertness, permeability and selective permeability. It can be applied in electronic skin, intelligent sensor, functional packaging, protective film, wound dressing, scar paste, gas separation film in electronic, agriculture, manufacturing, pharmaceutical industry and other fields. In the above applications of organosilicone film, gas permeability is an important factor affecting the application effect of the film. For example, wound dressing with good permeability is conducive to wound healing, and good permeability selectivity is conducive to improving the separation effect of the separation membrane. The permeability of the organosilicone film is related to the molecular structure and the morphological structure of the film. Therefore, the test of the permeability of the organosilicone film can provide a data reference for adjusting the production process of the film. Test Sample In this test, a type of organosilicone film is used as the test sample to test the carbon dioxide permeability of the sample. Standard At present, the principle of differential pressure method is mainly used to test the carbon dioxide transmission of flexible plastic packaging materials. The test process is based on ISO 2556 - Plastics -- Determination of the gas transmission rate of films and thin sheets under atmospheric pressure -- Manometric method Test Instrument In this paper, the VAC-V2 Differential Pressure Gas Permeability Tester is used as the test

 Open the catalog to page 1
gas permeability tester for Organosilicone film-2

instr rument to te the carbo dioxide t est on transmission rate of sam mples. The te instrume is test ent inde ependently de eveloped and produced by Jinan Labthi Instrumen Co., Ltd. ink nts Test Principle ntial pressure method ref e fers to the measurement of the gas transmission rate m n The differen ugh nge ure e lamped sample divides th test chamb of he ber throu the chan of pressu during the test. The cl the i instrument in upper and lower chamb nto bers, the uppe chamber is filled with th gas to be tested er he t (in t this paper, t gas to be tested is c the e carbon dioxide), the low chamber...

 Open the catalog to page 2
gas permeability tester for Organosilicone film-3

thickness, test mode, test temperature, humidity and other parameter information on the control software of the instrument, click “test” and switch on the vacuum pump to start the test. The instrument runs the test according to the set parameters, and the test results are displayed after the test. Test Results The results of the three samples were 2.671×105cm3/(m2·24h·0.1MPa), 2.704×105cm3/(m2·24h·0.1MPa) and 2.693×105cm3/(m2·24h·0.1MPa). The arithmetic mean value of the three samples was 2.689×105cm3/(m2·24h·0.1MPa). Conclusion Gas permeability is an important performance index of organosilicone...

 Open the catalog to page 3

All Labthink Instruments Co., Ltd. catalogs and technical brochures

  1. C610M

    3  Pages

  2. C690H

    4  Pages

  3. C130H

    4  Pages

  4. COF-P01

    2  Pages

  5. VAC-V2

    3  Pages

  6. C230H (2025)

    4  Pages

  7. C610H

    3  Pages

  8. C206H

    4  Pages

  9. C406H

    5  Pages

  10. C403H

    5  Pages

  11. C 681M

    1  Page

  12. C660B (2025)

    3  Pages

  13. C632M

    3  Pages

  14. C630H

    3  Pages

  15. C620H

    3  Pages

  16. C 640

    4  Pages

  17. C 660M

    3  Pages

  18. C306H (2025)

    4  Pages

  19. C203H

    4  Pages

  20. BTY-B3P

    2  Pages

  21. C360M

    4  Pages

  22. C632B

    3  Pages

  23. C190H

    3  Pages

  24. C390H

    4  Pages

  25. C360H

    4  Pages

  26. C660M

    3  Pages

  27. C303H

    4  Pages

  28. C106H

    5  Pages

  29. C640

    4  Pages

  30. MXD-02

    2  Pages

  31. CHY-C2A

    2  Pages

  32. C611B

    2  Pages

  33. CH130

    4  Pages

  34. C 631 H

    2  Pages

  35. C660 B

    3  Pages

  36. VAC-VBS

    3  Pages

  37. XYD-15K

    2  Pages

  38. C360

    4  Pages

  39. C631 H

    2  Pages

  40. FST-02

    2  Pages

  41. C681 M

    2  Pages

  42. C230

    4  Pages

  43. C631H

    2  Pages

  44. C612M

    3  Pages

  45. SLY-SI

    2  Pages

  46. C360 M

    4  Pages

  47. C611M

    2  Pages

  48. C330H

    4  Pages

  49. Leak Tester

    3  Pages

  50. Tensile Testers

    19  Pages

  51. FDI-01

    5  Pages

  52. DIN 75201

    2  Pages

  53. Abrasion Test

    2  Pages

  54. Torque Meter

    2  Pages

  55. Leak Detector

    2  Pages

  56. Torque tester

    2  Pages

  57. Impact tester

    2  Pages

  58. Gas Analyzer

    2  Pages

  59. TOQUE TESTER

    1  Page

Archived catalogs

  1. C611M

    2  Pages

  2. C306H

    3  Pages

  3. C230H

    4  Pages

  4. Leak Tester

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.