Introduction
Gas permeability testing is essential for maintaining the shelf life and quality of packaged goods across various industries. The selection of the right testing instrument is critical, given the multitude of available options and methods. This document highlights two primary factors to consider: blank test data and test result repeatability.
The Challenge of Consistent Results
Achieving consistent and accurate results in gas permeability testing is challenging due to factors such as instrument design, sensor precision, and environmental conditions. Discrepancies can arise between instruments from different manufacturers. To address these challenges, the document suggests focusing on two evaluation criteria:
  • Blank Test Data: This involves sealing a gas-impermeable material in the instrument and measuring pressure changes over time. Minimal pressure changes indicate a more accurate instrument, reflecting its inherent errors like system leakage.
  • Test Result Repeatability: This refers to the instrument's ability to consistently reproduce results across multiple tests on the same sample. Statistical measures such as standard deviation and coefficient of variation are used to assess repeatability, with higher repeatability indicating a more reliable instrument.
Case Study: Labthink C106H Gas Permeability Tester
The Labthink C106H is an automatic gas permeability tester. A blank test using a copper foil specimen demonstrates the instrument's minimal sensitivity to temperature and humidity changes. Additionally, repeatability data from oxygen permeability tests on various specimens show how material permeability affects data variation.
Conclusion
By evaluating both blank test data and test result repeatability, researchers and quality control professionals can make informed decisions when selecting gas permeability testing instruments. These criteria offer a comprehensive assessment of an instrument's inherent errors and its ability to deliver consistent results across different materials and permeability ranges. Labthink encourages collaboration with packaging industry companies for enhanced quality control.
See more

Catalog excerpts

Choosing the Right Gas Permeability Testing Instrument Data & Repeatability Are Key-1

Labthink Instruments Co., Ltd. [email protected] +86-531-85068566 Choosing the Right Gas Permeability Testing Instrument Data & Repeatability Are Key Keywords: Gas permeability testing, instrument selection, blank test, repeatability, data evaluation Gas permeability testing is crucial for various industries, ensuring the shelf life and quality of packaged goods. However, with an increasing number of instruments and methods, obtaining consistent and accurate results can be challenging. This article explores two key factors to consider when choosing a gas permeability testing instrument: blank test data and test result repeatability. The Challenge of Consistent Results The accuracy of gas permeability testing is influenced by various factors, including the instrument's design, sensor precision, and even the test environment. These factors can lead to discrepancies between instruments from different manufacturers. To address this challenge, the article proposes two evaluation criteria: Blank Test Data: This test reflects the instrument's inherent errors arising from system leakage and other uncontrollable factors. A reliable blank test involves sealing a gasimpermeable material in the instrument and measuring the pressure change over time. Lower pressure changes indicate a more accurate instrument. Test Result Repeatability: Repeatability refers to the instrument's ability to produce consistent results for multiple tests on the same sample. Statistical measures like standard deviation and coefficient of variation help evaluate repeatability. A higher repeatability signifies a more reliable instrument.

 Open the catalog to page 1
Choosing the Right Gas Permeability Testing Instrument Data & Repeatability Are Key-2

Labthink Instruments Co., Ltd. [email protected] +86-531-85068566 Labthink C106H Gas Permeability Tester is an automatic test equipment. Take the blank test with a copper foil specimen as an example, this test demonstrates the instrument’s minimal influence from temperature and humidity fluctuations. Additionally, repeatability data from oxygen permeability tests on various specimens highlight the impact of material permeability on data variation. In conclusion, by considering both blank test data and test result repeatability, researchers and quality control professionals can make informed decisions...

 Open the catalog to page 2

All Labthink Instruments Co., Ltd. catalogs and technical brochures

  1. C610M

    3  Pages

  2. C690H

    4  Pages

  3. C130H

    4  Pages

  4. COF-P01

    2  Pages

  5. VAC-V2

    3  Pages

  6. C230H (2025)

    4  Pages

  7. C610H

    3  Pages

  8. C206H

    4  Pages

  9. C406H

    5  Pages

  10. C403H

    5  Pages

  11. C 681M

    1  Page

  12. C660B (2025)

    3  Pages

  13. C632M

    3  Pages

  14. C630H

    3  Pages

  15. C620H

    3  Pages

  16. C 640

    4  Pages

  17. C 660M

    3  Pages

  18. C306H (2025)

    4  Pages

  19. C203H

    4  Pages

  20. BTY-B3P

    2  Pages

  21. C360M

    4  Pages

  22. C632B

    3  Pages

  23. C190H

    3  Pages

  24. C390H

    4  Pages

  25. C360H

    4  Pages

  26. C660M

    3  Pages

  27. C303H

    4  Pages

  28. C106H

    5  Pages

  29. C640

    4  Pages

  30. MXD-02

    2  Pages

  31. CHY-C2A

    2  Pages

  32. C611B

    2  Pages

  33. CH130

    4  Pages

  34. C 631 H

    2  Pages

  35. C660 B

    3  Pages

  36. VAC-VBS

    3  Pages

  37. XYD-15K

    2  Pages

  38. C360

    4  Pages

  39. C631 H

    2  Pages

  40. FST-02

    2  Pages

  41. C681 M

    2  Pages

  42. C230

    4  Pages

  43. C631H

    2  Pages

  44. C612M

    3  Pages

  45. SLY-SI

    2  Pages

  46. C360 M

    4  Pages

  47. C611M

    2  Pages

  48. C330H

    4  Pages

  49. Leak Tester

    3  Pages

  50. Tensile Testers

    19  Pages

  51. FDI-01

    5  Pages

  52. DIN 75201

    2  Pages

  53. Abrasion Test

    2  Pages

  54. Torque Meter

    2  Pages

  55. Leak Detector

    2  Pages

  56. Torque tester

    2  Pages

  57. Impact tester

    2  Pages

  58. Gas Analyzer

    2  Pages

  59. TOQUE TESTER

    1  Page

Archived catalogs

  1. C611M

    2  Pages

  2. C306H

    3  Pages

  3. C230H

    4  Pages

  4. Leak Tester

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.