1. Catalogs
  2. Labthink Instruments Co., Ltd.
  3. C201B Oxygen Transmission Rate Test System

C201B Oxygen Transmission Rate Test System

C201B Oxygen Transmission Rate Test System

C201B Oxygen Transmission Rate Test System

Product catalog summary
Overview:
The C201B Oxygen Transmission Rate Test System is designed to measure the oxygen transmission rate of barrier materials using the coulometric sensor method, conforming to ASTM D3985 standards. It is suitable for testing materials used in various industries such as food, pharmaceuticals, and electronics.

Features:
  • Equipped with a Labthink self-developed coulometric sensor, no calibration required.
  • Optional temperature control for testing under different conditions.
  • High-quality stainless steel test cell for improved sealing.
  • Manual isolation valve and flow regulator for enhanced performance.
  • Compact industrial design with fast cooling.
  • Reference film for quick calibration.
  • Independent operation with single-chip microcomputer control.
  • Exportable test reports in EXCEL and PDF formats.
  • Optional micro printer for automatic data printing.
  • RS232 data interface for computer connectivity and data analysis.
  • Optional gas purifier to remove trace oxygen in nitrogen.

Test Principle:
The specimen is clamped in a test cell where oxygen or air flows on one side and high purity nitrogen on the other. Oxygen permeates through the specimen into the nitrogen side and is analyzed by the sensor to calculate the oxygen transmission rate.

Standards:
Conforms to ASTM D3985, ASTM F1307, GB/T 19789, GB/T 31354, DIN 53380-3, JIS K7126-2-B, YBB 00082003-2015.

Applications:
  • Testing oxygen transmission rates of various films and sheets including plastic, paper-plastic composites, aluminized films, and more.
  • Applicable to PP, PVC, PVDC sheets, metal foils, rubber pads, and silicon wafers.

Technical Specifications:
  • Test range: 0.1 to 200 cc/(m2·day).
  • Resolution: 0.1 cc/(m2·day).
  • Test temperature: 15 to 50°C (optional).
  • Temperature resolution: 0.1°C.
  • Temperature fluctuation: ±0.5°C.
  • Test cell: 1 cell.
  • Specimen size: 9.7cm x 9.7cm.
  • Specimen thickness: ≤3mm.
  • Standard test area: 50cm2.
  • Test gas: 99.999% high purity nitrogen, 99.5% oxygen.
  • Gas pressure: 7.2 PSI / 50 kPa.
  • Instrument dimensions: 33cm x 43cm x 40cm.
  • Power supply: 120VAC±10% 60Hz / 220VAC±10% 50Hz.
  • Net weight: 23kg.

Product Configuration:
  • Standard: Instrument mainframe, sampler, vacuum grease.
  • Optional: Professional software, GP-01 Gas Purifier, TC03 temperature control device, computer system requirement, micro-printer.

Notes:
Product specifications are subject to change without notification. Labthink reserves the right to modify and interpret the specifications.
See more

Catalog excerpts

C201B Oxygen Transmission Rate Test System-1

C201B Oxygen Transmission Rate Test System C201B Oxygen Transmission Rate Test System is designed and manufactured based on the coulometric sensor method and conforms to ASTM D3985. This instrument can be used to measure the oxygen transmission rate of barrier materials with high and medium barrier properties with high accuracy and high efficiency. C201B is applicable to the determination of oxygen permeability of plastic films, sheeting, paper, and other packaging materials used in food, pharmaceutical, medical apparatus, consumer products, photovoltaic and electronic industries, etc. Features note1 • Equipped with Labthink self-developed coulometric sensor conforming to ASTM D3985, intrinsic standard and no calibration is required • Support temperature control to satisfy tests under different conditions (optional) • Built-in high-quality stainless steel test cell with better sealing performance • Imported manual isolation valve and flow regulator are adopted for better sealing performance and lower failure rate • Industrial computer appearance design, small size and fast cooling • Reference film is provided for quick calibration • The system adopts single-chip microcomputer control and can run independently • The test report can be exported in common formats such as EXCEL and PDF • Support micro printer, automatically print test data (optional) • Equipped with RS232 data interface, which can be connected to computer software for curve analysis, data storage, report printing, etc. (optional) • The gas purifier independently developed by Labthink can remove trace oxygen in nitrogen and provide oxygen-free carrier gas (optional). Labthink Instruments Co., Ltd. 144 Wuyingshan Road, Jinan, P.R.China (250031) Phone: +86-531-85068566 FAX: +86-531-85062108 Labthink International, Inc. 200 River's Edge Drive, Medford, MA, 02155, U.S.A. Phone:+1-617-830-2190 FAX: +1-781-219-3638 www.labthink.com

 Open the catalog to page 1
C201B Oxygen Transmission Rate Test System-2

Test principle The pre-conditioned specimen is clamped in the test cell, oxygen or air flows on one side of the specimen while a stream of high purity nitrogen flows on the other side. Oxygen molecules permeate through the specimen into the nitrogen side and are carried to the coulometric sensor. The sensor analyzes the oxygen concentration and calculates the oxygen transmission rate. Standards ASTM D3985x ASTM F1307x GB/T 19789x GB/T 31354x DIN 53380-3x JIS K7126-2-Bx YBB 00082003-2015 Oxygen transmission rate test of various plastic films, paper-plastic composite films, coextruded films, aluminized...

 Open the catalog to page 2
C201B Oxygen Transmission Rate Test System-3

TC03 Temperature control device Optional Table 2: Technical specifications Test Cell Specimen Size Specimen Thickness Standard test area 99.999% High purity nitrogem 99.5%Oxygen (Outside supply scope) Port Size Instrument Dimension Table 3: Product Configuration Standard Configuration Instrument mainframe, sampler, vacuum grease Optional Parts Professional software, GP-01 Gas Purifier ,TC03 temperature control device, Computer System requirement, Micro-printer Note 1: The described product functions are subject to the specification in "Technical Parameters” Note 2: The parameters in the table...

 Open the catalog to page 3

All Labthink Instruments Co., Ltd. catalogs and technical brochures

  1. C610M

    3  Pages

  2. C690H

    4  Pages

  3. C130H

    4  Pages

  4. COF-P01

    2  Pages

  5. VAC-V2

    3  Pages

  6. C230H (2025)

    4  Pages

  7. C610H

    3  Pages

  8. C206H

    4  Pages

  9. C406H

    5  Pages

  10. C403H

    5  Pages

  11. C 681M

    1  Page

  12. C660B (2025)

    3  Pages

  13. C632M

    3  Pages

  14. C630H

    3  Pages

  15. C620H

    3  Pages

  16. C 640

    4  Pages

  17. C 660M

    3  Pages

  18. C306H (2025)

    4  Pages

  19. C203H

    4  Pages

  20. BTY-B3P

    2  Pages

  21. C360M

    4  Pages

  22. C632B

    3  Pages

  23. C190H

    3  Pages

  24. C390H

    4  Pages

  25. C360H

    4  Pages

  26. C660M

    3  Pages

  27. C303H

    4  Pages

  28. C106H

    5  Pages

  29. C640

    4  Pages

  30. MXD-02

    2  Pages

  31. CHY-C2A

    2  Pages

  32. C611B

    2  Pages

  33. CH130

    4  Pages

  34. C 631 H

    2  Pages

  35. C660 B

    3  Pages

  36. VAC-VBS

    3  Pages

  37. XYD-15K

    2  Pages

  38. C360

    4  Pages

  39. C631 H

    2  Pages

  40. FST-02

    2  Pages

  41. C681 M

    2  Pages

  42. C230

    4  Pages

  43. C631H

    2  Pages

  44. C612M

    3  Pages

  45. SLY-SI

    2  Pages

  46. C360 M

    4  Pages

  47. C611M

    2  Pages

  48. C330H

    4  Pages

  49. Leak Tester

    3  Pages

  50. Tensile Testers

    19  Pages

  51. FDI-01

    5  Pages

  52. DIN 75201

    2  Pages

  53. Abrasion Test

    2  Pages

  54. Torque Meter

    2  Pages

  55. Leak Detector

    2  Pages

  56. Torque tester

    2  Pages

  57. Impact tester

    2  Pages

  58. Gas Analyzer

    2  Pages

  59. TOQUE TESTER

    1  Page

Archived catalogs

  1. C611M

    2  Pages

  2. C306H

    3  Pages

  3. C230H

    4  Pages

  4. Leak Tester

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.